GENERATOR/CHARGING SYSTEM
8-28
RECTIFIER INSPECTION
Check for continuity between the terminals according to
the table below.
• Some testers have reverse polarity.
PARALLEL OPERATION OUTLET
INSPECTION
There must be continuity between the outlet and
terminal.
AC CIRCUIT PROTECTOR INSPECTION
There should be continuity between the terminals with
the AC circuit protector in the ON position.
2
1
3
4
12
(+)Tester probe
Connector
(-)T
e
ster probe
Connector
Terminal
1
2
3
4
1
-
2
Continuity
-
Continuity
Continuity
3
Continuity
-
4
Continuity
-
12
12