58
SERVICING YOUR GENERATOR
Battery Charging
Battery Installation
The battery gives off explosive
hydrogen gas during normal
operation.
A spark or flame can cause the
battery to explode with enough
force to kill or seriously hurt you.
Wear protective clothing and a face
shield, or have a skilled mechanic
perform the battery maintenance.
Connect the battery negative (
) cable to the battery negative (
)
terminal, and tighten the bolt securely.
Slide the battery boot over the positive (
) cable and terminal.
Connect the battery positive (
) cable to the battery positive (
)
terminal first, and tighten the bolt securely.
Install the battery into the generator.
Clean the outside of the battery and the battery compartment with a
solution of baking soda and water.
Connect the battery charger following the manufacturer’s
instructions.
The battery is rated at 11.2 Ah (ampere-hours). Charging current
should equal 10% of the battery’s ampere-hour rating. A battery
charger should be used that can be adjusted to deliver 1.1 amps.
Charge the battery 5
10 hours.
Install the battery strap.
Install the maintenance cover in the reverse order of removal (see
page
Never operate the generator without the maintenance cover in place,
as poor engine and generator performance will result.
1.
2.
3.
1.
2.
3.
4.
5.
6.
11/03/27 08:01:06 31Z11710_059
Summary of Contents for EM5000is
Page 1: ......
Page 79: ...77 TECHNICAL CONSUMER INFORMATION Wiring Diagram 11 03 27 08 04 03 31Z11710_078 ...
Page 100: ...98 MEMO 11 03 27 08 06 56 31Z11710_099 ...
Page 101: ...99 MEMO 11 03 27 08 06 58 31Z11710_100 ...
Page 102: ...100 MEMO 11 03 27 08 07 01 31Z11710_101 ...
Page 104: ...00X31Z117200 ...