14
CONTROL & FEATURES
Voltage Selector Switch
Switch Position
AC Circuit Protectors
120/240 V:
120 V ONLY:
PUSH
ON
CIRCUIT PROTECTOR
for Receptacle
CIRCUIT PROTECTOR
for Receptacle
CIRCUIT PROTECTOR
for Receptacle
OFF
CIRCUIT PROTECTOR
for Receptacle
120 V 20 A
120 V 30 A
120 V 20 A
VOLTAGE SELECTOR SWITCH
120 V/240 V
120 V ONLY
AC CIRCUIT PROTECTOR
120/240 V
30 A
Select the voltage before starting the engine.
The voltage selector switch switches generator output to produce
‘‘120 V ONLY’’ or ‘‘120 V/240 V.’’ If a 240 V appliance is connected to
the 4-prong receptacle, the switch must be in the ‘‘120 V/240 V’’
position. If only a 120 V appliance is being connected to any of the
120 V 3-prong receptacles, select the ‘‘120 V ONLY’’ position.
Always disconnect or turn OFF all appliances or tools connected to the
generator before changing the voltage selector switch position.
The 120 V and 120 V/240 V receptacles can be used
simultaneously.
ONLY the 120 V receptacles can be used. Do not use the
120 V/240 V receptacle in this position. The most power will be
available at the 30 A 120 V locking plug receptacle.
The AC circuit protectors will automatically switch OFF if there is a
short circuit or a significant overload of the generator at each
receptacle. If an AC circuit protector switches OFF automatically, check
that the appliance is working properly and does not exceed the rated
load capacity of the circuit before resetting the AC circuit protector ON.
11/03/27 07:54:36 31Z11710_015
Summary of Contents for EM5000is
Page 1: ......
Page 79: ...77 TECHNICAL CONSUMER INFORMATION Wiring Diagram 11 03 27 08 04 03 31Z11710_078 ...
Page 100: ...98 MEMO 11 03 27 08 06 56 31Z11710_099 ...
Page 101: ...99 MEMO 11 03 27 08 06 58 31Z11710_100 ...
Page 102: ...100 MEMO 11 03 27 08 07 01 31Z11710_101 ...
Page 104: ...00X31Z117200 ...