INITIAL USE INFORMATION

Add Engine Oil

The generator is 
shipped 

WITHOUT OIL

 

in the engine. Place the 
generator on a level 
surface. Remove the oil 
filler cap/dipstick.
All Honda engines are 
run at the factory prior to 
packaging. Most of the 
oil is removed prior to 
shipment; however, 
some oil remains in the 
engine. The amount of 
oil left in the engine 
varies.
Add enough SAE 
10W-30 API service 
category SJ or later oil 
to bring the oil level to 
the upper limit of the oil filler neck (approximately 12 to 13.5 ounces is 
required). 10W-30 motor oil is recommended for general use. For 
additional recommendations, see 

page 12

.

Do not overfill the engine with oil

. If the engine is overfilled, the 

excess oil may get transferred to the air cleaner housing and air filter. 
An indication of overfilling is white or blue smoke coming from the 
muffler when the engine is running.
After filling the engine with oil, screw the oil filler cap/dipstick in and 
remove the hang tag located on the fuel cap that says “

The engine 

has no oil.

Fuel

Add fuel to the generator in a well-ventilated area. Never refuel the 
engine inside a building where gasoline fumes may reach flames or 
sparks. Keep gasoline away from appliance pilot lights, barbecues, 
electric appliances, power tools, etc. Spilled fuel is not only a fire 
hazard, it causes environmental damage. Wipe up spills immediately.
This engine is certified to operate on unleaded gasoline with a pump 
octane rating of 86 or higher containing no more than 10% ethanol 
(E10) or 5% methanol by volume. Refer to 

page 11

 for additional fuel 

recommendations.

1. Remove the fuel tank cap.
2. Add fuel slowly to prevent spilling. Do not fill the fuel tank above 

the upper level mark (red) on the fuel strainer. Overfilling the fuel 
tank may cause fuel to leak out of the bottom of the EVAP canister.

3. After adding fuel, reinstall the fuel tank cap securely.
Move the generator at least 10 feet (3 meters) away from the fueling 
source and site before starting the engine.

NOTICE

Fuel can damage paint and plastic. Be careful not to spill fuel when 
filling your fuel tank. Damage caused by spilled fuel is not covered 
under the DISTRIBUTOR’S LIMITED WARRANTY.

Please Register Your Generator

Please take a few minutes and register your purchase with Honda. 
You can register:
• By completing and mailing the registration card on the back cover of 

this book

• Going on-line to powerequipment.honda.com and clicking on 

Product Registration

• By scanning the QR code

Before Using Your Generator

All Generator operators must read the following sections:
• FOR YOUR SAFETY (

page 2

)

• GENERATOR SAFETY(

page 2

)

• BEFORE EACH USE (

page 5

)

• OPERATION (

page 7

)

• STARTING THE ENGINE (

page 7

)

• STOPING THE ENGINE (

page 8

)

• MAINTENANCE SCHEDULE (

page 10

)

 WARNING

Gasoline is highly flammable and explosive.
You can be burned or seriously injured when handling 

fuel. 
• Stop the engine and let it cool before refueling
• Keep heat, sparks, and flame away
• Refuel only outdoors
• Wipe up spills immediately

OIL FILLER 
CAP/DIPSTICK

OIL FILLER NECK

UPPER LIMIT

UPPER LEVEL MARK (RED)
(Do not overfill)

FUEL TANK CAP

Summary of Contents for EG2800i

Page 1: ...Air Index 16 Controls 6 Air Cleaner 12 Specifications 16 Features 6 Spark Plug 12 Wiring Diagram 17 OPERATION 7 Sediment Cup Cleaning 13 AVOIDING FUEL RELATED PROBLEMS 18 Safe Operating Instructions 7...

Page 2: ...table power requirements Other uses can result in injury to the operator or damage to the generator and other property Most injuries or property damage can be prevented if you follow all the instructi...

Page 3: ...ignite some materials Keep the generator at least 3 feet 1 meter away from buildings and other equipment during operation Do not enclose the generator in any structure Keep flammable materials away f...

Page 4: ...ctane rating of 86 or higher containing no more than 10 ethanol E10 or 5 methanol by volume Refer to page 11 for additional fuel recommendations 1 Remove the fuel tank cap 2 Add fuel slowly to prevent...

Page 5: ...for signs of damage Check each control for proper operation Check that all nuts bolts and screws are tightened Check the air filter page 12 and oil level page 11 Check the fuel level page 7 Starting w...

Page 6: ...OFF position to reduce voltage changes ON Recommended to minimize fuel consumption and further reduce noise levels when less than a full load is applied to the generator OFF The Eco Throttle system d...

Page 7: ...ings and other equipment Do not operate the generator in an enclosed structure Do not place flammable objects close to the engine or locate the generator near flammable materials Starting the Engine T...

Page 8: ...wer cord can create a potential for electrical shock If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn it off immediately Disconnect the appliance and determine whet...

Page 9: ...able to your individual needs and use Remember that an authorized Honda servicing dealer knows your generator best and is fully equipped to maintain and repair it To ensure the best quality and reliab...

Page 10: ...able failures Item Action Before each use 5 hours of use or first month 25 hours of use or every 3 months 50 hours of use or every 6 months 100 hours of use or every year 250 hours of use or every 2 y...

Page 11: ...e DISTRIBUTOR S LIMITED WARRANTY If your equipment will be used on an infrequent or intermittent basis please refer to the fuel section of the STORAGE chapter page 13 for additional information regard...

Page 12: ...inside Never try to brush off dirt brushing will force dirt into the fibers 5 Foam Air Filter Wash the foam air filter in a solution of household detergent and warm water then rinse thoroughly or wash...

Page 13: ...el Position the generator so that its base is level on the bed of the transport vehicle Tie the generator down with rope or straps Keep the tie down rope or straps away from the controls Do not operat...

Page 14: ...cover A nonporous cover will trap moisture around the generator promoting rust and corrosion Removing from Storage Check your generator as described in BEFORE EACH USE on page 5 If the engine cylinder...

Page 15: ...ontrol systems to reduce the emissions of carbon monoxide oxides of nitrogen and hydrocarbons Additionally Honda fuel systems utilize components and control technologies to reduce evaporative emission...

Page 16: ...tended 300 hours 0 80 cc 500 hours greater than 80 cc 1000 hours 225 cc and greater EG2800i Lightweight inverter generator with Eco Throttle Length 16 9 in 430 mm Width 17 6 in 448 mm Overall height 1...

Page 17: ...17 Wiring Diagram...

Page 18: ...k it before each use A properly maintained air filter will help prevent dirt from entering the carburetor The small passages inside the carburetor can become blocked 3 to 4 Weeks Before Next Use Reaso...

Page 19: ...detailed description of the problem Honda Publications These publications will give you information for maintaining and repairing your generator Owner s Manual Keep this owner s manual handy so you c...

Page 20: ...w limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above exclusions and limitations may not apply to you...

Page 21: ...place other engine components damaged by a failure of any warranted part during the warranty period The use of replacement parts not equivalent to the original parts may impair the effectiveness of yo...

Page 22: ...22 NOTES...

Page 23: ...ne Complete and mail the postage paid card shown below Complete and submit the on line form at powerequipment honda com Scan the QR code below and then complete and submit the on line form commercial...

Page 24: ...ick Submit It s that simple Power Equipment Division American Honda Motor Co Inc 4900 Marconi Dr Alpharetta GA 30005 9956 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES Product Registration BUSIN...

Reviews: