Honda EG2800i Owner'S Manual Download Page 6

6

Controls

Fuel Valve Lever

The fuel valve lever is 
located between the 
fuel tank and 
carburetor.
The fuel valve lever 
must be in the ON 
position for the engine 
to run.
After stopping the 
engine, turn the fuel 
valve lever to the OFF 
position.

Choke Rod

The choke rod opens and 
closes the choke valve in the 
carburetor.
Pulling the choke rod to the 
CLOSED position enriches the 
fuel mixture for starting a cold 
engine.
Pushing the choke rod to the OPEN position provides the correct fuel 
mixture for operation after starting, and for restarting a warm engine.

Engine Switch

The engine switch controls the 
ignition system.
OFF - Stops the engine.
ON - Running position, and for 
starting with the recoil starter.

Recoil Starter

Pulling the starter grip 
operates the recoil starter to 
crank the engine.

NOTICE

Do not allow the starter grip 
to snap back against the 
engine. Return it gently to prevent damage to the starter.
Do not let the starter rope rub against the generator body, or the rope 
will wear out prematurely.

AC Circuit 
Protector

The AC circuit protector 
will automatically switch 
to OFF if there is a short 
circuit or a significant 
overload of the 
generator at the 20A 
receptacles. If an AC 
circuit protector 
switches OFF 
automatically, check that 
the appliance is working 
properly and does not exceed the rated load capacity of the circuit 
before resetting the AC circuit protector ON.

ECO THROTTLE

® 

Switch

The Eco Throttle system 
automatically reduces engine 
speed when loads are turned 
off or disconnected. When 
appliances are turned on or 
reconnected, the engine 
returns to the proper speed to 
power the electrical load.
If high electrical loads are connected simultaneously, turn the Eco 
Throttle switch to the OFF position to reduce voltage changes.

ON: 

Recommended to minimize fuel consumption and further reduce 

noise levels when less than a full load is applied to the generator.

OFF:

 The Eco Throttle system does not operate. Generator operates 

at full speed.

Features

Output Indicator

The output indicator (green) is 
illuminated when the generator 
is operating normally. It 
indicates that the generator is 
producing electrical power at 
the receptacles.
In addition, the output indicator 
has a simplified hour meter 
function. When you start the 
engine, the indicator blinks according to the generator’s cumulative 
operating hours as follows:

Overload Alarm 
(Indicator)

If the generator is overloaded 
(in excess of 2.8kVA), or if there 
is a short circuit in a connected 
appliance, the overload alarm 
(red) will come ON. The 
overload alarm (red) will stay 
ON, and after about 4~10 seconds, current to the connected 
appliance(s) will shut off, and the output indicator (green) will go OFF. 
However, the engine will continue to run.

Oil Alert

®

 

Indicator/Check

The Oil Alert system is 
designed to prevent engine 
damage caused by an 
insufficient amount of oil in the 
crankcase. Before the oil level 
in the crankcase can fall below 
a safe limit, the Oil Alert indicator/check (red) comes on and the Oil 
Alert system automatically will stop the engine (the engine switch will 
remain in the ON position).
If the engine stops or the Oil Alert indicator/check (red) comes on 
when you pull the starter grip, check the engine oil level (

page 11

before troubleshooting in other areas.

OFF

ON

FUEL 
VALVE 
LEVER

CHOKE ROD

OPEN

CLOSED

ENGINE 
SWITCH

OFF

ON

STARTER 
GRIP

AC CIRCUIT 
PROTECTORS

OFF

ON

PUSH 
TO 
RESET

20A RECEPTACLES

• No blinks: 0~100 hours

• 3 blinks: 300~400 hours

• 1 blink: 100~200 hours

• 4 blinks: 400~500 hours

• 2 blinks: 200~300 hours

• 5 blinks: 500 or more hours

ECO-THROTTLE 
SWITCH

OFF

ON

OUTPUT 
INDICATOR 
(GREEN)

OVERLOAD 
ALARM (RED)

OIL ALERT 
INDICATOR/
CHECK (RED)

Summary of Contents for EG2800i

Page 1: ...Air Index 16 Controls 6 Air Cleaner 12 Specifications 16 Features 6 Spark Plug 12 Wiring Diagram 17 OPERATION 7 Sediment Cup Cleaning 13 AVOIDING FUEL RELATED PROBLEMS 18 Safe Operating Instructions 7...

Page 2: ...table power requirements Other uses can result in injury to the operator or damage to the generator and other property Most injuries or property damage can be prevented if you follow all the instructi...

Page 3: ...ignite some materials Keep the generator at least 3 feet 1 meter away from buildings and other equipment during operation Do not enclose the generator in any structure Keep flammable materials away f...

Page 4: ...ctane rating of 86 or higher containing no more than 10 ethanol E10 or 5 methanol by volume Refer to page 11 for additional fuel recommendations 1 Remove the fuel tank cap 2 Add fuel slowly to prevent...

Page 5: ...for signs of damage Check each control for proper operation Check that all nuts bolts and screws are tightened Check the air filter page 12 and oil level page 11 Check the fuel level page 7 Starting w...

Page 6: ...OFF position to reduce voltage changes ON Recommended to minimize fuel consumption and further reduce noise levels when less than a full load is applied to the generator OFF The Eco Throttle system d...

Page 7: ...ings and other equipment Do not operate the generator in an enclosed structure Do not place flammable objects close to the engine or locate the generator near flammable materials Starting the Engine T...

Page 8: ...wer cord can create a potential for electrical shock If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn it off immediately Disconnect the appliance and determine whet...

Page 9: ...able to your individual needs and use Remember that an authorized Honda servicing dealer knows your generator best and is fully equipped to maintain and repair it To ensure the best quality and reliab...

Page 10: ...able failures Item Action Before each use 5 hours of use or first month 25 hours of use or every 3 months 50 hours of use or every 6 months 100 hours of use or every year 250 hours of use or every 2 y...

Page 11: ...e DISTRIBUTOR S LIMITED WARRANTY If your equipment will be used on an infrequent or intermittent basis please refer to the fuel section of the STORAGE chapter page 13 for additional information regard...

Page 12: ...inside Never try to brush off dirt brushing will force dirt into the fibers 5 Foam Air Filter Wash the foam air filter in a solution of household detergent and warm water then rinse thoroughly or wash...

Page 13: ...el Position the generator so that its base is level on the bed of the transport vehicle Tie the generator down with rope or straps Keep the tie down rope or straps away from the controls Do not operat...

Page 14: ...cover A nonporous cover will trap moisture around the generator promoting rust and corrosion Removing from Storage Check your generator as described in BEFORE EACH USE on page 5 If the engine cylinder...

Page 15: ...ontrol systems to reduce the emissions of carbon monoxide oxides of nitrogen and hydrocarbons Additionally Honda fuel systems utilize components and control technologies to reduce evaporative emission...

Page 16: ...tended 300 hours 0 80 cc 500 hours greater than 80 cc 1000 hours 225 cc and greater EG2800i Lightweight inverter generator with Eco Throttle Length 16 9 in 430 mm Width 17 6 in 448 mm Overall height 1...

Page 17: ...17 Wiring Diagram...

Page 18: ...k it before each use A properly maintained air filter will help prevent dirt from entering the carburetor The small passages inside the carburetor can become blocked 3 to 4 Weeks Before Next Use Reaso...

Page 19: ...detailed description of the problem Honda Publications These publications will give you information for maintaining and repairing your generator Owner s Manual Keep this owner s manual handy so you c...

Page 20: ...w limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above exclusions and limitations may not apply to you...

Page 21: ...place other engine components damaged by a failure of any warranted part during the warranty period The use of replacement parts not equivalent to the original parts may impair the effectiveness of yo...

Page 22: ...22 NOTES...

Page 23: ...ne Complete and mail the postage paid card shown below Complete and submit the on line form at powerequipment honda com Scan the QR code below and then complete and submit the on line form commercial...

Page 24: ...ick Submit It s that simple Power Equipment Division American Honda Motor Co Inc 4900 Marconi Dr Alpharetta GA 30005 9956 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES Product Registration BUSIN...

Reviews: