Homewardbath GH21-HT Installation & Operation Manual Download Page 13

3.

 

Keypad and steam outlet are installed according to the drawing below.  Steam generator must be installed out 
of the steam enclosure.  The keypad can be installed according to the situation on site.  Drill 

ɸ

20 hole for wire.  

Tear the sticker off keypad and stick it on the wall.   

 

When using the internal temperature sensor of the keypad: 

 

The keypad should be placed shoulder high when occupant will be sitting.   

 

When using the external temperature sensor: 

 

The sensor should be placed shoulder high when occupant will be sitting.   The sensor 

must

 be as far away from the steam outlet as possible. 

 

4.

 

Install the steam outlet on the wall.  The steam outlet is G3/4 thread connector.  Leave 3/16

in 

(30mm) outside 

the wall.  Seal the connector with Teflon tape and connect the steam outlet like drawing below shows.  The gap 
is sealed with high temperature resistant material.  Outlet should be no closer than 10in from the floor and no 
higher that 15in from the floor. 
The steam outlet should be installed face down. Wrap a few circles Teflon tape around the threads of the steam 
pipe, install the steam nozzle and tighten with hands. Do not tighten the steam head onto the steam pipe. It may 

cover the steam head’s output holes.

 

 

Warning: The steam outlet will get very hot!

  It should not be installed near the individual sitting inside.

 

 
Note: Aromatherapy oils are placed in the indentation at the top of the steam nozzle. 
Attention:

 In order to protect the steam nozzle, do not use any tools to tighten that will scratch finish, use a 

little soapy water and soft sponge to wipe, and do not use corrosive chemical solutions or abrasive cleaning 
tools. 

Attention:

 Please consult your distributors of building materials like acrylic, fiberglass or other heat-resistant 

material around the installation and position of steam nozzle. It is suggested that MS-103412 heat resistant 
material is used. 

Summary of Contents for GH21-HT

Page 1: ...Steam Planet Superior Encore Steam Generator Installation Operation Manual 6kW 9kW 12kW 18kW 24kW Rev 6 2022...

Page 2: ...ule Introduction 7 Reset Introduction 7 Choosing the proper location 8 Keypad Diagram 8 Keypad Introduction 9 Dual Keypad Setup 10 Common Installation Problems 11 Suggested Steam Room Layout 11 Instal...

Page 3: ...tering or leaving b The steam head is hot Do not touch the steam head and avoid the steam near the steam head c Prolonged use of the steam system can raise excessively the internal human body temperat...

Page 4: ...er Power Space Voltage Max Current Wire DIA 6kW 140 320ft 220 240V 27 3A 10 ro 6MM 9kW 320 460ft 220 240V 41A 10 ro 6MM 12kW 460 700ft 220 240V 55A 6 ro 10MM 18kW 700 920ft Two 220 240V Lines Two 41A...

Page 5: ...ed 11ft power cable External temperature sensor External temperature sensor foundation 12ft power box extension cable 9 5ft cable for keypad or generator connection 1ft light cable 25ft cable for sing...

Page 6: ...Wiring Diagram...

Page 7: ...V with 2 pin SIM2 54 connector Module Introduction The system consists of power box GH21 PB control module GH21EE Bluetooth module GH21 BT and steam module GS08 HW Power box GH21 PB provides 14v DC Th...

Page 8: ...ft between steam generator and any other object 9 The place where the machine is installed must be accessible for cleaning and possible service work 10 The steam generator should be in a close proximi...

Page 9: ...Keypad Introduction...

Page 10: ...e Icon is highlighted on the keypad the current temperature will be displayed 2 Press and hold the dial in the steam room temperature will be displayed and the thermometer in the display will start to...

Page 11: ...e reading Power box issues Make sure the wiring that connects the power box to the keypad and steam generator is not damaged Suggested Steam Room Layout Installation 1 For wall mounting Steam generato...

Page 12: ...ctor b Drain G1 2 thread connector Must be copper for at least first 3ft from the generator c Steam outlet G3 4 thread connector d Steam line Must use copper Insulate the line with high temp 212 plus...

Page 13: ...ture resistant material Outlet should be no closer than 10in from the floor and no higher that 15in from the floor The steam outlet should be installed face down Wrap a few circles Teflon tape around...

Page 14: ...Circuit Diagram for 6kW 9kW...

Page 15: ...Circuit Diagram for 12kW...

Page 16: ...ning Both openings go to the tank Fill the tank until the solution starts to come out of the steam outlet or the pressure relief valve opening Replace the steam line or the pressure relief valve then...

Reviews: