12/17
ALFA IN a.s ©
www.alfain.eu
8. Press the torch trigger and check, eventually set the working pressure to
4,0 bar on the regulator
A9
.
REQUIREMENTS
FOR SOURCE OF COMPRESSED AIR
1. Delivered air pressure must be max. 8,5 bar and min. 4,0 bar.
2. Air consumption 140 l/min.
3. Compressed air for the plasma must be clean and dry.
4. Pressure dew point +3 °C.
5. Maximum oil content 0.1 mg/m3.
6. Maximal size of solid particles 15 microns.
7. The sufficient size of an air tank is 25 l.
8. No additional oiling if the pressure air is permitted. That could damage the
plasma machine and the cutting torch.
OPTIONAL AIR FILTERS FOR HOMER PLASMACUT 39
To achieve high quality cutting and to avoid serious disturbances to the torch it
is highly advised to include the air filter. The filter needs to be connected to the
machine by means of the hoses adapter.
Pos.
Code
Description
23
4801
Adapter hoses for filter AT 1000
24
5302
Air Filter AT 1000
25
5304
Adapter for AT 1000 PEGAS PLASMA
Fig. 3 – Air filter AT 1000