BASIC OPERATION

Local Control

The button on the ZDP100 allows the user to

Turn ON, OFF or DIM and BRIGHTEN the load attached to the controlled outlet.

Include or exclude the module from the Z-Wave system

When a controller prompts you to “Send Node ID” or to “Press Button on Unit”, quickly tap  the button on the ZDP100
once to satisfy those instructions.  Further operation of button:

 Tapping button toggles the load attached

Pressing and holding the button will dim or brighten the load attached.

Operation Note

When a light bulb reaches the end of it’s life and burns out, it sometimes creates a momentary short circuit.  The
high current that results may cause the dimmer to respond by turning off.   Should this happen, replace the bulb
with a new one.  The dimmer can now be operated to restore power to the light.

Remote Control

The ZDP100 will respond to BASIC and MULTILEVEL commands that are part of the Z-Wave system. Refer to
your controller’s instructions as to whether your controller can transmit those commands.

See the information in the section titled 

Version

for a complete list of commands the ZDP100 will support.

ADVANCED OPERATION

Protection

The ZDP100 supports the Protection Command.

The ZDP100 can be set to any one of 3 

Protection

 modes by a wireless controller. Refer to your controller for

information on how to set the various modes of Protection. Some controllers may only be able to set certain settings
of Protection.

There are 3 modes of Protection:

1.  No Protection

2.  Child Protection

3.  Button on ZDP100 totally disabled

When Protection is set to “

No Protection

” mode, the ZDP100 works normally.

When Protection is set to “Child Protection” mode, you will have to press the button 3 times rapidly to toggle the
attached load.  Tap the button twice then press and hold it to dim or brighten the attached load. The ZDP100
operates normally if controlled by a wireless controller.

When Protection is set to “

Enable Total Protection

” mode, the button will not work. You will be able to turn the load

on and off only with a wireless controller, however the button can still be used to access the Z-Wave network for
programming.

All On/All Off

The ZDP100 supports the ALL ON/ ALL OFF commands.

The ZDP100 can be set to respond to ALL ON and ALL OFF commands 4 different ways.

Refer to your controller for information on how to set the ZDP100 to operate in the manner you desire. Some
controllers may be only able to set certain settings of ALL ON/ALL OFF response.

The 4 different ways the ZDP100 can be setup to respond to ALL ON and ALL OFF commands are:

•   

ZDP100 will not respond to ALL ON or the ALL OFF command.

•   

ZDP100 will respond to ALL OFF command but will not respond to ALL ON command.

•   

ZDP100 will respond to ALL ON command but will not respond to ALL OFF command.

•   

ZDP100 will respond to ALL ON and the ALL OFF command.

Summary of Contents for ZDP100

Page 1: ...an 300 watts To reduce the risk of electric shock this product has a grounding type plug that has a third grounding pin This plug will only fit into a grounding type power outlet If the plug does not fit into the outlet contact a qualified electrician to install the proper outlet Do not change the plug in any way WARNING Plugging a non resistive load such as florescent lighting or a device with a ...

Page 2: ... wireless controller Refer to your controller for informationonhowtosetthevariousmodesof Protection Somecontrollersmayonlybeabletosetcertainsettings of Protection There are 3 modes of Protection 1 No Protection 2 Child Protection 3 Button on ZDP100 totally disabled When Protection is set to No Protection mode the ZDP100 works normally When Protection is set to Child Protection mode you will have t...

Page 3: ...rying to transmit The ZDP100 will only request an update when a transmission fails SPECIFICATIONS Power 120 VAC 60 Hz Signal Frequency 908 42 MHz Maximum Load 300 W for incandescent lamps only Note A minimum 25 watt load is recommended for the load sense feature and dimming capabilities of this product to operate properly Range Up to 100 feet line of sight between the Wireless Controller and or th...

Page 4: ...ff and on the user is encouraged to try to correct the interfer ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help IC NOTICE This Cl...

Page 5: ...ule DO NOT use a CFL compact fluorescent light bulb The light module works like a dimmer switch and will not function properly with CFL and LED bulbs or electric devices with motors like fans Make sure that lamp switch is in the ON position Pass through three prong outlet 1500 watts maximum is NOT controlled by the system and functions as a standard electrical outlet 2 Max 300W Incandescent Z Wave...

Page 6: ......

Reviews: