HomeMatic HmIP-eTRV-C Mounting Instruction And Operating Manual Download Page 35

35

Information about this manual

Information about this manual

Please read this manual carefully before beginning op-
eration with your Homematic IP component. Keep the 
manual so you can refer to it at a later date if you need to. 
If you hand over the device to other persons for use, 
please hand over this manual as well.

Symbols used:

Attention! 

This indicates a hazard.

Please note:

This section contains important additional infor-
mation.

Hazard information

Do not open the device. It does not contain any 
parts that can be maintained by the user. In the 
event of an error, please have the device checked 
by an expert.

For safety and licensing reasons (CE), unauthor-
ized change and/or modification of the device is 
not permitted.

Summary of Contents for HmIP-eTRV-C

Page 1: ...Montage und Bedienungsanleitung Mounting instruction and operating manual Heizkörperthermostat kompakt S 2 Radiator Thermostat compact p 33 HmIP eTRV C ...

Page 2: ...eproduziert werden oder unter Verwendung elektronischer mechanischer oder chemischer Verfahren verviel fältigt oder verarbeitet werden Es ist möglich dass die vorliegende Anleitung noch drucktech nische Mängel oder Druckfehler aufweist Die Angaben in dieser Anleitung werden jedoch regelmäßig überprüft und Korrekturen in der nächsten Ausgabe vorgenommen Für Fehler technischer oder drucktechnischer ...

Page 3: ...2 1 A E C B D ...

Page 4: ...3 4 ...

Page 5: ...5 6 H G F ...

Page 6: ...8 7 I ...

Page 7: ... 16 5 2 2 Stützring 17 5 2 3 Adapter für Danfoss 17 5 3 Adaptierfahrt 21 5 4 Demontageschutz montieren 22 6 Batterien wechseln 23 7 Fehlerbehebung 25 7 1 Schwache Batterien 25 7 2 Befehl nicht bestätigt 25 7 3 Duty Cycle 26 7 4 Fehlercodes und Blinkfolgen 27 8 Wiederherstellung der Werkseinstellungen 29 9 Wartung und Reinigung 30 10 Allgemeine Hinweise zum Funkbetrieb 30 11 Technische Daten 31 12 ...

Page 8: ...assen übergeben Sie auch diese Anleitung Benutzte Symbole Achtung Hier wird auf eine Gefahr hingewiesen Hinweis Dieser Abschnitt enthält zusätzliche wichtige Informationen 2 Gefahrenhinweise Öffnen Sie das Gerät nicht Es enthält keine durch den Anwender zu wartenden Teile Im Fehlerfall lassen Sie das Gerät von einer Fachkraft prüfen Aus Sicherheits und Zulassungsgründen CE ist das eigenmächtige Um...

Page 9: ...fährlichen Spielzeug werden Bei Sach oder Personenschäden die durch un sachgemäße Handhabung oder Nichtbeachten der Gefahrenhinweise verursacht werden über nehmen wir keine Haftung In solchen Fällen er lischt jeder Gewährleistungsanspruch Für Folge schäden übernehmen wir keine Haftung Bitte beachten Sie dass die Regelung der Raum temperatur über den Heizkörperthermostat auf ein Zweirohrheizsystem ...

Page 10: ...eren und Heizphasen auf Ihre individuellen Bedürfnisse anpassen Nach Bedarf können Sie drei verschiedene Heizprofile mit bis zu 6 Heizphasen pro Tag anlegen Der Heizkörperthermostat kann einfach an den Home matic IP Access Point angelernt werden und z B in Ver bindung mit dem Homematic IP Fenster und Türkontakt die Temperatur beim Lüften automatisch abzusenken Zur exakten Regelung der Raumtemperat...

Page 11: ...tagekontakt alarmiert Sie über die Homema tic IP App bei Manipulation oder unbefugtem Öffnen des Batteriefachs Durch den mitgelieferten Demontageschutz ist der Heiz körperthermostat vor Diebstahl und unbefugter Demon tage geschützt Der Demontageschutz ist ideal für den Einsatz in öffentlichen Einrichtungen oder Bürogebäuden und lässt sich einfach ohne zusätzliches Montagematerial am Heizkörpervent...

Page 12: ...ngen zu betreiben Welcher Funktionsumfang sich innerhalb des Systems im Zusammenspiel mit wei teren Komponenten ergibt entnehmen Sie bitte dem Homematic IP Anwenderhandbuch Alle technischen Dokumente und Updates finden Sie stets aktuell unter www eQ 3 de 5 Inbetriebnahme 5 1 Anlernen Bitte lesen Sie diesen Abschnitt erst vollständig bevor Sie mit dem Anlernen beginnen Sie können das Gerät an den A...

Page 13: ...en Homematic IP Access Point ange lernt werden Zum Anlernen des Heizkörperthermostats gehen Sie wie folgt vor Öffnen Sie die Homematic IP App auf Ihrem Smartphone Wählen Sie den Menüpunkt Gerät anlernen aus Öffnen Sie das Schloss des Batteriefachs E mit dem mitgelieferten Vierkantschlüssel s Abbil dung 2 Nehmen Sie den Batteriefachdeckel B ab indem Sie ihn im ersten Schritt nach hinten und im zwei...

Page 14: ...N ein oder scannen Sie den QR Code Die Gerätenummer finden Sie auf dem Aufkleber im Lieferumfang oder direkt am Gerät Warten Sie bis der Anlernvorgang abgeschlossen ist Zur Bestätigung eines erfolgreichen Anlernvor gangs leuchtet die LED C grün Das Gerät ist nun einsatzbereit Leuchtet die LED rot versuchen Sie es erneut Vergeben Sie in der App einen Namen für das Ge rät und ordnen Sie es einem Rau...

Page 15: ...izkörperthermostat angebrachte Metallmutter A ist universell einsetzbar und ohne Zubehör passend für alle Ventile mit dem Gewindemaß M30 x 1 5 mm der gängigsten Hersteller wie z B Heimeier MNG Junkers Landis Gyr Duodyr Honeywell Braukmann Oventrop Schlösser Comap Valf Sanayii Mertik Maxitrol Watts Wingenroth Wiroflex R B M Tiemme Jaga Siemens und Idmar Durch die im Lieferumfang enthaltenen Adapter...

Page 16: ... leichter demontiert werden Die Fixierung des Thermostatkopfes kann unterschiedlich ausgeführt sein Überwurfmutter Schrauben Sie die Überwurf mutter gegen den Uhrzeigersinn ab F Danach können Sie den Thermostatkopf abnehmen H Schnappbefestigungen Sie können so befestigte Thermostatköpfe einfach lösen indem Sie den Verschluss Überwurfmutter ein klein wenig ge gen den Uhrzeigersinn drehen F Danach k...

Page 17: ...oder den beiliegenden Stützring s 5 2 2 Stütz ring auf Seite 17 5 2 2 Stützring Bei den Ventilen einiger Hersteller weist der in das Gerät hineinragende Teil des Ventils nur einen geringen Durch messer auf was zu einem lockeren Sitz des Heizkörper thermostat führt In diesem Fall sollte der beiliegende Stützring I vor der Montage in den Flansch des Geräts eingelegt werden s Abbildung 7 5 2 3 Adapte...

Page 18: ...chfolgende Abbildungen Danfoss RA Die Ventilkörper von Danfoss weisen umlaufend längliche Einkerbungen 1 auf die auch einen besseren Sitz des Adapters nach dem Aufrasten gewährleisten Achten Sie bei der Montage darauf dass die Zap fen im Inneren des Adapters 2 eine deckungs gleiche Position zu den Einkerbungen 1 am Ventil haben Rasten Sie den zum Ventil passen den Adapter vollständig auf Nach dem ...

Page 19: ...pters nach dem Aufrasten gewährleisten Achten Sie bei der Montage darauf dass die Zap fen im Inneren des Adapters 2 eine deckungs gleiche Position zu den Einkerbungen 1 am Ventil haben Rasten Sie den zum Ventil passen den Adapter vollständig auf Auf Ventile vom Typ RAV ist vor der Montage die Stößel verlängerung 3 auf den Ventilstift aufzusetzen ...

Page 20: ...h einen besseren Sitz des Adapters nach dem Aufrasten gewährleisten Achten Sie bei der Montage darauf dass die Zap fen im Inneren des Adapters 2 eine deckungs gleiche Position zu den Einkerbungen 1 am Ventil haben Rasten Sie den zum Ventil passen den Adapter vollständig auf Der Adapter RAVL muss nicht verschraubt werden ...

Page 21: ...kgefahren wur de Motor fährt nicht mehr kann der Heizkörperthermo stat montiert werden s Abbildung 6 Zur Anpassung an das Ventil muss eine Adaptierfahrt durchgeführt werden Gehen Sie dazu wie folgt vor Um die Adaptierfahrt zu starten schließen Sie nach der Montage das Batteriefach E mit dem Vier kantschlüssel s Abbildung 2 3 Die Adaptierfahrt wird alternativ automatisch 3 Minuten nach Errei ...

Page 22: ...lgebers ertönt dieser zusätzlich parallel zur LED Durch Drehen des Batteriefach schlosses mit dem Vierkantschlüssel s Abbildung 2 fährt der Motor zurück zur Ventilstiftendposition 5 4 Demontageschutz montieren Bei Bedarf können Sie den beiliegenden Demontage schutz verwenden um den Heizkörperthermostat vor Diebstahl und unbefugter Demontage zu schützen Für die Montage gehen Sie wie folgt vor Steck...

Page 23: ...heint das Symbol für leere Bat terien in der App tauschen Sie die verbrauchten Batterien gegen zwei neue Batterien des Typs LR6 Mignon AA aus Beachten Sie dabei die richtige Polung der Batterien Um neue Batterien in den Heizkörperthermostat einzule gen gehen Sie wie folgt vor Öffnen Sie das Schloss des Batteriefachs E mit dem mitgelieferten Vierkantschlüssel s Abbil dung 2 ...

Page 24: ...sel Achten Sie nach dem Einlegen der Batterien auf die Blinkfolgen der LED s 7 4 Fehlercodes und Blinkfolgen auf Seite 27 Nach dem Einlegen der Batterien führt der Heizkörper thermostat zunächst für ca 2 Sekunden einen Selbsttest durch Danach erfolgt die Initialisierung Den Abschluss bildet die Test Anzeige oranges und grünes Leuchten Batterien dürfen niemals aufgeladen werden Batterien nicht ins ...

Page 25: ...linkfolgen auf Seite 27 Tauschen Sie in diesem Fall die leeren Batterien gegen zwei neue aus s 6 Batterien wechseln auf Seite 23 7 2 Befehl nicht bestätigt Bestätigt mindestens ein Empfänger einen Be fehl nicht leuchtet zum Abschluss der fehlerhaf ten Übertragung die Geräte LED C rot auf Grund für die fehlerhafte Übertragung kann eine Funk störung sein s 10 Allgemeine Hinweise zum Funkbetrieb auf ...

Page 26: ...Limits nicht mehr senden bis diese zeitliche Begrenzung vorüber ist Gemäß dieser Richtlinie werden Homematic IP Geräte zu 100 nor menkonform entwickelt und produziert Im normalen Betrieb wird der Duty Cycle in der Regel nicht erreicht Dies kann jedoch in Einzelfällen bei der In betriebnahme oder Erstinstallation eines Systems durch vermehrte und funkintensive Anlernprozesse der Fall sein Eine Über...

Page 27: ...h zu groß Überprüfen Sie die Befestigung des Heizkörperther mostats Kurzes oranges Blinken Funküber tragung Sendeversuch bzw Konfi gurationsda ten werden übertragen Warten Sie bis die Übertragung beendet ist 1x langes grünes Leuchten Vorgang bestätigt Sie können mit der Bedienung fortfahren 1x langes rotes Leuchten Vorgang fehlgeschla gen oder Duty Cycle Limit erreicht Versuchen Sie es erneut s 7 ...

Page 28: ...leer Tauschen Sie die Batterien aus s 6 Batterien wechseln auf Seite 23 6x langes rotes Blinken Gerät defekt Achten Sie auf die Anzeige in Ihrer App oder wenden Sie sich an Ihren Fachhändler 1x oranges und 1x grünes Leuchten nach dem Einlegen der Batterien Testanzeige Nachdem die Test anzeige erloschen ist können Sie fortfahren Langes und kurzes oran ges Blinken im Wechsel Aktualisierung der Gerät...

Page 29: ...teriefachdeckel B ab indem Sie ihn im ersten Schritt nach hinten und im zwei ten Schritt nach oben abziehen s Abbildung 3 Entnehmen Sie eine Batterie Legen Sie die Batterie entsprechend der Polari tätsmarkierungen wieder ein s Abbildung 8 und halten Sie gleichzeitig die Systemtaste C für 4 s gedrückt bis die LED schnell orange zu blinken beginnt s Abbildung 4 Lassen Sie die Systemtaste wieder los ...

Page 30: ...iftung können dadurch angegriffen werden 10 Allgemeine Hinweise zum Funkbetrieb Die Funk Übertragung wird auf einem nicht exklusiven Übertragungsweg realisiert weshalb Störungen nicht ausgeschlossen werden können Weitere Störeinflüsse können hervorgerufen werden durch Schaltvorgänge Elektromotoren oder defekte Elektrogeräte Die Reichweite in Gebäuden kann stark von der im Freifeld abweichen Außer ...

Page 31: ...Kurzbezeichnung HmIP eTRV C Versorgungsspannung 2x 1 5 V LR6 Mignon AA Stromaufnahme 100 mA max Batterielebensdauer 3 Jahre typ Schutzart IP20 Verschmutzungsgrad 2 Umgebungstemperatur 0 bis 50 C Abmessungen B x H x T 51 x 98 x 48 mm Gewicht 172 g inkl Batterien Funk Frequenzband 868 0 868 6 MHz 869 4 869 65 MHz Max Funk Sendeleistung 10 dBm Empfängerkategorie SRD category 2 Typ Funk Freifeldreichw...

Page 32: ...räte sind entsprechend der Richtlinie über Elektro und Elektronik Altgeräte über die örtlichen Sammelstellen für Elektronik Altgeräte zu entsorgen Konformitätshinweis Das CE Zeichen ist ein Freiverkehrszeichen das sich ausschließlich an die Behörden wendet und keine Zusicherung von Eigenschaften beinhaltet Bei technischen Fragen zum Gerät wenden Sie sich bitte an Ihren Fachhändler ...

Page 33: ...her in whole or in part nor may it be duplicated or edited by electronic mechanical or chemical means without the written consent of the publisher Typographical and printing errors cannot be excluded However the information contained in this manual is reviewed on a regular basis and any necessary corrections will be implemented in the next edition We accept no liability for technical or typographi...

Page 34: ...ng the radiator thermostat 42 5 2 2 Support ring 43 5 2 3 Adapter for Danfoss 44 5 3 Adaption run 48 5 4 Mounting the disassembly protection 49 6 Replacing batteries 50 7 Troubleshooting 51 7 1 Weak batteries 51 7 2 Command not confirmed 52 7 3 Duty cycle 52 7 4 Error codes and flashing sequences 53 8 Restore factory settings 55 9 Maintenance and cleaning 56 10 General information about radio oper...

Page 35: ...o other persons for use please hand over this manual as well Symbols used Attention This indicates a hazard Please note This section contains important additional infor mation 2 Hazard information Do not open the device It does not contain any parts that can be maintained by the user In the event of an error please have the device checked by an expert For safety and licensing reasons CE unauthor i...

Page 36: ...ge to property or personal injury caused by improper use or the failure to observe the hazard informa tion In such cases any claim under warranty is extinguished For consequential damages we as sume no liability Please note that the room temperature control via the radiator thermostat is designed for a two pipe heating system with one feed and return line per radiator Use in single pipe heating sy...

Page 37: ... profiles with up to 6 heating phases per day The radiator thermostat can simply be connected to the Homematic IP Access Point In connection with the Homematic IP Window Door Contact the temperature is automatically reduced during ventilation For precise regulation of the room temperature a Homematic IP Wall Thermostat or Temperature and Humidity Sensor can measure the actual temperature of a room...

Page 38: ...mpartment With the supplied disassembly protection the radiator thermostat is protected against theft and unauthorised disassembly The disassembly protection is ideal for use in public institutions or office buildings and is easy to in stall on the radiator valve without additional mounting tools Device overview see figure 1 A Metal nut B Battery compartment cover C System button teach in button a...

Page 39: ...ination with other components are described in the Homematic IP Wired Installation Guide All current technical documents and updates are provided at www eQ 3 com 5 Start up 5 1 Teaching in Please read this entire section before starting the teach in procedure You can connect the device either to the Access Point or to the Homematic Central Control Unit CCU2 CCU3 For detailed information about teac...

Page 40: ...roceed as follows Open the Homematic IP app on your smart phone Select the menu item Teach in device Open the lock of the battery compartment E using the supplied four Allen head wrench see figure 2 Remove the battery compartment cover B to the back and downwards to remove it from the device see figure 3 Remove the insulation strip from the battery compartment of the radiator thermostat The teach ...

Page 41: ...ase try again In the app give the device a name and allocate it to a room Do not yet close the battery compartment see 5 3 Adaption run on page 48 5 2 Mounting Please read this entire section before starting to mount the device The Homematic IP Radiator Thermostat is easy to install and can be done without draining heating water or in tervening in the heating system No special tools are re quired ...

Page 42: ...the radiator thermostat In case of visible damage of the existing radiator valve or heating pipes please contact a specialist Remove the old thermostat dial from your radiator valve To do this please proceed as follows Rotate the thermostat dial to the maximum value G anti clockwise see figure 5 The thermostat dial then no longer presses against the valve spig ot making it easier to remove There a...

Page 43: ...t head H After removing the old thermostat dial you can mount the Homematic IP Radiator Thermostat with the metal nut A to the radiator valve see figure 6 If required you can use one of the supplied adapters for Danfoss valves see 5 2 3 Adapter for Danfoss on page 44 or the supplied support ring see 5 2 2 Support ring on page 43 5 2 2 Support ring The valves from different manufacturers may have t...

Page 44: ...valve can be found in the following illus trations Please ensure that you do not trap your fingers between the two halves of the adapter The RA and RAV adapters have been manufactured with pre tension in order to provide a better seat Use a screw driver during installation if necessary and bend it open slightly in the vicinity of the screw see following figures ...

Page 45: ...e adapter is properly seated when it snaps on During installation please ensure that the pins in side the adapter 2 are lined up with the notches 1 on the valve Ensure that a suitable adapter for the valve is properly clipped on After clipping onto the valve body please attach the adapter using the provided screw and nut 1 2 ...

Page 46: ...he adapter is properly seated when it snaps on During installation please ensure that the pins in side the adapter 2 are lined up with the notches 1 on the valve Ensure that a suitable adapter for the valve is properly clipped on The lifter extension 3 must be fitted to the valve pin of RAV valves prior to installation 2 3 1 ...

Page 47: ... which also ensure that the adapter is properly seated when it snaps on During installation please ensure that the pins in side the adapter 2 are lined up with the notches 1 on the valve Ensure that a suitable adapter for the valve is properly clipped on The adapter RAVL does not have to be screwed 2 1 ...

Page 48: ... 3 The adaption run is alternatively started 3 minutes after reaching the valve pin end position Now the radiator thermostat performs the adapting run After the adaption run installation is completed and the device can be individually configured and controlled If the adaption run was initiated prior to installation or if it could not be fully performed the device LED C lights up red up to 10 times...

Page 49: ... the radiator thermostat against theft and unauthorised disassembly For the installation please proceed as follows Place the upper J and lower K shell above the nut or the pre mounted radiator thermostat and allow the parts to snap into place After engaging the upper and lower shell the parts can no longer be separated J K ...

Page 50: ...ery compartment E using the supplied four Allen head wrench see figure 2 Remove the battery compartment cover B to the back and downwards to remove it from the device see figure 3 Remove the empty batteries Insert two new 1 5 V LR6 mignon AA batteries into the battery compartment making sure that you in sert them the right way round see figure 8 Re insert the battery compartment cover and close th...

Page 51: ...mestic waste Instead take them to your local battery disposal point 7 Troubleshooting 7 1 Weak batteries Provided that the voltage value permits it the radiator thermostat will remain ready for operation also if the bat tery voltage is low Depending on the particular load it may be possible to send transmissions again repeatedly once the batteries have been allowed a brief recovery period If the v...

Page 52: ...e transmis sion time of devices in the 868 MHz range The aim of this regulation is to safeguard the operation of all devices working in the 868 MHz range In the 868 MHz frequency range we use the maximum transmission time of any device is 1 of an hour i e 36 seconds in an hour Devices must cease transmission when they reach the 1 limit until this time restriction comes to an end Homematic IP devic...

Page 53: ...on Short red flashing in 10 s intervals Valve drive sluggish or adjustment range too small Please check whether the valve pin is stuck Short red flashing in 10 s intervals Actuating range too wide Please check the fastening if the ra diator thermostat Short orange flashing Radio transmission attempting to transmit con figuration data is transmitted Wait until the transmission is completed 1x long ...

Page 54: ...the last four numbers of the device serial number to confirm see 5 1 Teaching in on page 39 Short orange lighting after green or red confirmation Batteries empty Replace the batter ies see 6 Replac ing batteries on page 50 6x long red flashing Device defec tive Please see your app for error mes sage or contact your retailer 1x orange and 1 x green lighting after inserting bat teries Test display O...

Page 55: ...Open the lock of the battery compartment E using the supplied four Allen head wrench see figure 2 Remove the battery compartment cover B to the back and downwards to remove it from the device see figure 3 Remove a battery Insert the battery ensuring that the polarity is correct see figure 8 while pressing and holding down the system button C for 4s at the same time until the LED will quickly start...

Page 56: ...eaning The device does not require you to carry out any maintenance other than replacing the battery when necessary Enlist the help of an expert to carry out any repairs Clean the device using a soft lint free cloth that is clean and dry Do not use any detergents containing solvents as they could corrode the plastic housing and label ...

Page 57: ...on within buildings can differ greatly from that available in the open air Besides the transmitting power and the reception characteristics of the receiver environmental factors such as humidity in the vicinity have an important role to play as do on site structural screening conditions Hereby eQ 3 AG Maiburger Str 29 26789 Leer Germany declares that the radio equipment type Homematic IP HmIP eTRV...

Page 58: ...rature 0 to 50 C Dimensions W x H x D 51 x 98 x 48 mm Weight 172 g including batteries Radio frequency band 868 0 868 6 MHz 869 4 869 65 MHz Maximum radiated power 10 dBm Receiver category SRD category 2 Typ open area RF range 250 m Duty cycle 1 per h 10 per h Method of operation Type 1 Connection M30 x 1 5 mm Controlling torque 80 N Valve travel 4 3 0 3 mm Maximum travel position 14 3 0 3 mm Mini...

Page 59: ...e dis posed of at local collection points for waste elec tronic equipment in compliance with the Waste Electrical and Electronic Equipment Directive Information about conformity The CE sign is a free trading sign addressed ex clusively to the authorities and does not include any warranty of any properties For technical support please contact your retailer ...