32
33
replaced with a new Lithium cell of type CR 2016 as
described in the previous chapter.
Make sure that the battery is inserted with proper
polarity.
6.1.3 Behavior after changing batteries
After inserting the battery, the remote control will
run a self-test. This runs for approx. 2 seconds. The
initialization runs next. The completion is indicated
with the LED test display: red, green, orange, each
for a half second. If an error occurs, it is indicated
with red flashing!
One long flash, two
short flashes, pause
(repeated twice)
Battery power too low
One long flash, one
short flash, pause
(infinite)
Remote control
defective
If the battery power is low, as long as the power
level allows, the button actuation is activated and
the remote control is ready for operation. Depending
on the requirements, the battery may recover and
send again many times after a short break. If the
power drops too low when sending, the respective
error code is displayed again.
6.2 Teaching
Please read this section completely before starting
with any teaching!
The remote control supports three different modes
• Operation mode (normal operation)
• Configuration mode (for changing remote control
parameters)
• Teach mode (Teaching HomeMatic components)
Training requires that both devices to be connected
are put into teach mode and the desired channel is
selected for training.
The teach button is located on the back of the
remote control in the bottom left. This button is
located within a recess in the housing so that it
cannot be pressed accidentally.