HomeMatic HM-LC-BI1PBU-FM Installation And Operating Manual Download Page 69

69

12  Maintenance and cleaning

The product does not require any maintenance. 

Enlist the help of an expert to carry out any re

-

pairs. 

The device features an internal miniature fuse 
to protect the electronics against current over-
load. If the device is overloaded and the fuse 
blows, it can only be replaced by our service 
department!

The mains voltage must be disconnected be-
fore the device is removed (trip the miniature 

circuit-breaker)! Only qualified electricians (to 

VDE 0100) are permitted to carry out work on 
the 230 V mains. 

Summary of Contents for HM-LC-BI1PBU-FM

Page 1: ...d Bedienungsanleitung S 2 Installation and operating manual p 38 Funk Rollladenaktor 1 fach f r Markenschalter Unterputzmontage Wireless Shutter Actuator 1 channel for brand switch systems flush mount...

Page 2: ...werden Es ist m glich dass das vorliegende Handbuch noch drucktechnische M ngel oder Druckfehler aufweist Die Angaben in diesem Handbuch werden jedoch regelm ig berpr ft und Korrekturen in der n chst...

Page 3: ...on 16 7 1 Installation des Homematic Unterputz Rollladenaktors 18 8 Bedienung 24 8 1 Einfache Bedienung ber Tastwippe 24 8 2 Anlernen 24 8 3 Bedienfunktionen nach Anlernen 30 9 Werkseinstellungen wied...

Page 4: ...geben Sie auch diese Bedienungs anleitung Benutzte Symbole Achtung Hier wird auf eine Gefahr hin gewiesen Hinweis Dieser Abschnitt enth lt zus tzliche wichtige Informationen Hinweis Dieser Abschnitt e...

Page 5: ...n nicht damit zu spielen Lassen Sie das Verpackungsmaterial nicht achtlos liegen Plastikfolien t ten Styroporteile etc k nnten f r Kinder zu einem gef hrlichen Spielzeug werden Das Ger t darf nur f r...

Page 6: ...nnungsnetz zul ssig Arbeiten am 230 V Netz d rfen nur von einer Elektrofachkraft nach VDE 0100 erfolgen Dabei sind die gel tenden Unfallverh tungsvorschriften zu beach ten Zur Vermeidung eines elektri...

Page 7: ...alten geeignet Belasten Sie den Aktor nur bis zur angege benen Leistungsgrenze Eine berlastung kann zur Zerst rung des Ger tes zu einem Brand oder zu einem elektrischen Schlag f hren Der Aktor ist nur...

Page 8: ...llladenaktor eignet sich zur Installation innerhalb der im Haus montierten Un terputzdosen Er ist f r den Anschluss von Unterputzleitungen f r Wechselspannungsmotoren f r Rollladen Jalousien und Marki...

Page 9: ...ppt den Motor Bei einem langen Tastendruck wird der Motor so lange in die ent sprechende Richtung gefahren bis die Taste wieder losgelassen wird oder die Endlage erreicht ist Die Adapter f r verschied...

Page 10: ...10 unver ndert da vorhandene Rahmen und Wippen weiter genutzt werden k nnen B Config Taste A Anschlussklemmen...

Page 11: ...rh ltlich Wippadapter f r weitere Hersteller sind in Vorbereitung In Ausnahme f llen kann eine Anpassung der Wipphalterungen oder Rahmen der verschiedenen Hersteller durch S gen oder Feilen erforderli...

Page 12: ...12 Adapter f r Berker B1 Arsys K1 Adapter f r Berker B2 S1 Modul 2 B1 B3 B7 Q1 Adapter f r Busch Jaeger BJ Duro 2000 SI SI Linear Reflex SI SI Linear carat future linear solo Busch axcent alpha...

Page 13: ...f r Jung J1 LS 990 LS design LS plus CD 500 CD universal CD plus Adapter f r Jung J2 A 500 A creation A plus AS 500 AS universal Adapter f r Kopp K Alaska Athenis Ambiente Europa Paris Objekt HK 05 M...

Page 14: ...dapter f r Gira GD Standard Adapter f r Gira 55 G System 55 Standard 55 E2 Event Espirit Adapter f r d wi Popp D Architaste Arcada Trend Standard Quadro Plus2000 EverLuxe Forever ProLuxe Quadro PrimaL...

Page 15: ...nsumfang sich damit ergibt und welche Zusatzfunktionen sich im Homematic System im Zusammenspiel mit weiteren Komponenten ergeben entnehmen Sie bitte dem Homematic WebUI Handbuch Alle technischen Doku...

Page 16: ...mit den grundlegenden Anforde rungen und den anderen relevanten Vorschriften der Richtlinie 1999 5 EG befindet Die vollst ndige Konformit tserkl rung finden Sie unter www homematic com 7 Installation...

Page 17: ...feststellen Erden und Kurz schlie en benachbarte unter Spannung stehen de Teile abdecken oder abschranken Auswahl des geeigneten Werkzeuges der Messger te und ggf der pers nlichen Schutz ausr stung Au...

Page 18: ...putz Rollladenaktors Zugelassene Leitungsquerschnitte zum Anschluss an den Unterputz Aktor sind Starre Leitung mm2 Flexible Leitung mit und ohne Aderendh lse mm2 0 75 1 50 0 75 1 50 Bitte notieren Sie...

Page 19: ...ss Motor AB 2 Anschluss Motor AUF L Anschluss Au enleiter Die Installationsschritte sind entsprechend der Installationsanleitung vorzunehmen Bitte beachten Sie dabei die Gefahrenhinweise entsprechend...

Page 20: ...nenfalls die Wippe vom Rahmen des entsprechenden Schalters ab Ziehen Sie anschlie end den Rahmen mitsamt Klemm Haltest ck vom Schalter ab Das Klemm Haltest ck kann in Abh ngigkeit vom Hersteller trans...

Page 21: ...itt 5 Schlie en Sie den Au enleiter an An schlussklemme L an Schritt 6 Schlie en Sie den Neutralleiter an Anschlussklemme N an Schritt 7 Schlie en Sie den Neutralleiter des Motors an den Neutralleiter...

Page 22: ...Adapter auf der Wippe Schritt 10 Schalten Sie die Haussicherung des Stromkreises wieder ein Schritt 11 Jetzt k nnen beispielsweise Sender oder eine Zentrale an den Aktor angelernt werden siehe Kapite...

Page 23: ...den Rahmen an den Home matic Unterputz Rollladenaktor Platzieren Sie den Adapter dabei so dass die beiden Rasternasen in die vorhandenen Langl cher passen Bitte beachten Sie dass zwischen den Homemat...

Page 24: ...ale anlernen Ein kurzer Tastendruck der oberen oder unteren Wippenh lfte f hrt den Rollladen in die obere bzw untere Endposition Ein kurzer Tastendruck in die entgegengesetzte Richtung stoppt den Moto...

Page 25: ...n Homematic Ger ten kommunizieren kann muss das Ger t zun chst an gelernt werden Sie k nnen den Rollladenaktor direkt an andere Homematic Ger te z B eine Homematic Fernbedienung oder an die Homematic...

Page 26: ...ie den Anlernmodus wieder verlassen Bringen Sie nun das Ger t an das Sie den Rollla denaktor anlernen wollen gem der zugeh rigen Bedienungsanleitung in den Anlernmodus und w hlen ggf die gew nschte Ka...

Page 27: ...ernen neuer Ger te an die Zentrale erfolgt ber die Homematic Bedienoberfl che WebUI Sobald eine Komponente an eine Zentrale an gelernt ist kann sie nur noch ber diese mit anderen Komponenten verkn pft...

Page 28: ...Der Anlernmodus ist f r 60 Sekunden aktiv Das Info feld zeigt die aktuell noch verbleibende Anlernzeit Versetzen Sie innerhalb dieser Anlernzeit den Roll ladenaktor in den Anlernmodus indem Sie kurz m...

Page 29: ...osteingang wie im folgenden Abschnitt Neu ange lernte Ger te konfigurieren beschrieben 8 2 3 Neu angelernte Ger te konfigurieren Nachdem Sie Ihr Ger t an die Homematic Zentrale angelernt haben wird es...

Page 30: ...urzer Tastendruck entgegen Fahrtrichtung Fahrt stoppen langer Ta stendruck Fahren f r Tastendruckdauer Dabei ergibt sich das gleiche Verhalten wie beim Bedienen ber die Ger te Wippe Taste Verhalten Ku...

Page 31: ...itten Schritt 1 Entfernen Sie die Wippe aus dem Wippadapter Schritt 2 Halten Sie mit einem schmalen spitzen Gegenstand z B Kugelschreiber die Config Taste B f r mindestens 4 Se kunden gedr ckt bis die...

Page 32: ...Blinken Anlernmodus Schnelles Blinken Reset Einmal lang einmal kurz Sende Limit Duty Cycle erreicht Einmal lang zweimal kurz Ger t defekt 10 2 Anzeige des Betriebszustandes Sobald der Motor eingeschal...

Page 33: ...llte dabei ein Fehler festgestellt werden so wird dieses durch Blinken der LED dargestellt Dieses wiederholt sich kontinuierlich und das Ger t nimmt seine eigentliche Funktion nicht auf Damit bei Span...

Page 34: ...ung zum Schutz der Elektronik vor zu gro er Strombelastung Sollte das Ger t berlastet werden und die Sicherung ausl sen darf sie nur von unserem Service ersetzt werden Vor Ausbau des Ger tes unbedingt...

Page 35: ...art Motorlast Relais 1x Wechsler 1x Schlie er Funkfrequenz 868 3 MHz Empf ngerkategorie SRD Category 2 Typ Funk Freifeldreichweite 200 m Duty Cycle 1 pro h Schutzart IP20 Schutzklasse II Leistungsart...

Page 36: ...t nicht im Hausm ll entsorgen Elektro nische Ger te sind entsprechend der Richtlinie ber Elektro und Elektronik Altger te ber die rtlichen Sammelstellen f r Elektronik Altger te zu entsorgen Das CE Ze...

Page 37: ...37...

Page 38: ...hical and printing errors cannot be excluded However the information contained in this manual is reviewed on a regular basis and any necessary cor rections will be implemented in the next edition We a...

Page 39: ...allation 52 7 1 Installing the Homematic flush mounted blind actuator 54 8 Start up 59 8 1 Simple operator functions using connected pushbutton 59 8 2 Teaching in 60 8 3 Operating functions after teac...

Page 40: ...for use please hand over the operating manual as well Symbols used Attention This indicates a hazard Note This section contains additional important information Note This section contains additional...

Page 41: ...toy do not allow children to play with it Do not leave packaging material lying around plastic films bags pieces of polystyrene etc can be dangerous in the hands of a child The device may only be used...

Page 42: ...0 V 50 Hz AC supply Only qualified electricians to VDE 0100 are permitted to car ry out work on the 230 V mains Applicable ac cident prevention regulations must be complied with whilst such work is be...

Page 43: ...evice has not been designed to support safety disconnection Do not exceed the capacity specified for the actuator Exceeding this capacity could lead to the destruction of the device fires or electric...

Page 44: ...ave been adjusted correctly Before connecting the actuator is connected remove the fuse from the fuse box The device has not been designed to support safety disconnection 3 Function The Homematic flus...

Page 45: ...nted shutter actuator manually using the rocker at any time Pressing the relevant button briefly moves the connected motor to the corresponding limit position Briefly pressing the button for the oppos...

Page 46: ...ation to a minimum The design colour and finish of switches that have already been installed does not change since existing the frames and rockers can continue to be used B Config button A Connecting...

Page 47: ...e as accessories rocker adapters for other manufacturers are in preparation In exceptional cases the rocker holders or frames from the different manufacturers may need to be sawn or filed for adaptati...

Page 48: ...48 Adapter for Berker B1 Arsys K1 Adapter for Berker B2 S1 Modul 2 B1 B3 B7 Q1 Adapter for Busch Jaeger BJ Duro 2000 SI SI Linear Reflex SI SI Linear carat future linear solo Busch axcent alpha...

Page 49: ...for Jung J1 LS 990 LS design LS plus CD 500 CD universal CD plus Adapter for Jung J2 A 500 A creation A plus AS 500 AS universal Adapter for Kopp K Alaska Athenis Ambiente Europa Paris Objekt HK 05 M...

Page 50: ...dapter for Gira GD Standard Adapter for Gira 55 G System 55 Standard 55 E2 Event Espirit Adapter for d wi Popp D Architaste Arcada Trend Standard Quadro Plus2000 EverLuxe Forever ProLuxe Quadro PrimaL...

Page 51: ...hat can be made available in this way and the supplementary functions provided by the Homematic system when it is combined with other components are described in the Homematic WebUI Manual All current...

Page 52: ...on site structural screening conditions eQ 3 AG hereby declares that this device conforms with the essential requirements and other relevant re gulations of Directive 1999 5 EC The full declaration of...

Page 53: ...nect from mains Safeguard from swit ching on again Check that system is deenergi sed Earth and short circuit Cover or cordon off neighbouring live parts Select suitable tool measuring equipment and if...

Page 54: ...atic flush mounted blind actuator Permitted cable cross sections for connecting to the flush mounted actuator are Rigid cable mm2 Flexible cable with and without ferrule mm2 0 75 1 50 0 75 1 50 Before...

Page 55: ...connection DOWN 2 Motor connection UP L Phase conductor connection The installation steps must be carried out in accordance with the installation instructions Please note the safety instructions as pe...

Page 56: ...e frame of the relevant switch Then pull the frame off the switch together with the clamping retaining piece The clamping retaining piece can be transparent grey or black depending on the manufacturer...

Page 57: ...L Step 6 Connect the neutral conductor to con necting terminal N Step 7 Connect the neutral conductor of the motor to the neutral conductor of the house installation Step 8 Secure the Homematic flush...

Page 58: ...can now be taught in at the blind ac tuator see Chapter 8 2 Teaching in auf Seite 57 Step 12 Now secure the rocker to the radio actuator with the adapter and hold the frame at the Homematic flush mou...

Page 59: ...e Homematic central control unit 8 Start up 8 1 Simple operator functions using con nected pushbutton The actuator is ready for operation as soon as it has been installed You can a use it as a convent...

Page 60: ...lease read this entire section before starting the teach in procedure Before being able to use your device with QIVICON it has to be taught in to your QIVICON Home Base Therefore please log in to My Q...

Page 61: ...g ballpoint pen to start the 20 se cond teach in mode again Flashing of the LED in the Config button indicates that teach in mode is active Now put the device you wish to teach in the actuator into t...

Page 62: ...veniently controlled and configured connected directly to other devices or used in central control programs via the Homematic software WebUI Therefore your actuator has to be taught in to the Homemati...

Page 63: ...the right hand side of the screen To activate teach in mode click Teach in HM in the next window Teach in mode remains activated for 60 seconds An information box shows how much teach in time remains...

Page 64: ...Once you have taught in your actuator to the Home matic Central Control Unit it will be moved to the inbox Here you must configure the device and its associated channels in order to make them availab...

Page 65: ...n is released Press the button as follows to trigger the corresponding re sponse Button Response Press and release UP button Move to RETRACTED limit position Press and release DOWN button Move to EXTE...

Page 66: ...old down the Config button B for at least 4 seconds with a narrow pointed object e g a ballpoint pen until the LED in button starts to flash slowly Now release the button again Step 3 Press the button...

Page 67: ...ong one short Transmit limit duty cycle reached One long two short Device defective 10 2 Operating status display The device LED lights up permanently as soon as the motor is switched on Once the actu...

Page 68: ...its function If the test is completed without errors the actuator transmits a wireless telegram containing its status information To prevent all actuators from transmitting at the same time when powe...

Page 69: ...l miniature fuse to protect the electronics against current over load If the device is overloaded and the fuse blows it can only be replaced by our service department The mains voltage must be disconn...

Page 70: ...geover contact 1x NO contact Radio frequency 868 3 MHz Receiver category SRD category 2 Typ open area RF range 200 m Duty cycle 1 per h Degree of protection IP20 Protection class II Cable type cross s...

Page 71: ...not dispose of the device with regular do mestic waste Electronic equipment must be disposed of at local collection points for waste electronic equipment in compliance with the Waste Electrical and El...

Page 72: ...72 Bevollm chtigter des Herstellers Manufacturer s authorised representative eQ 3 AG Maiburger Stra e 29 26789 Leer GERMANY www eQ 3 de...

Reviews: