33
Behaviour after power recovery
7
Behaviour after power recovery
After the device has been inserted to a socket or after pow-
er recovery the pluggable switch performs a self-test/re-
start (approx. 2 seconds). The device LED flashes orange
and green briefly (LED test display). The LED will flash if
an error is detected during this test (see “8.3 Error codes
and flashing sequences” on page 34). This is repeated
continuously and the device does not perform its function.
If the test is completed without errors, the device transmits
a wireless telegram containing its status information.
8
Troubleshooting
8.1
Command not confirmed
If at least one receiver does not confirm a command, the
device LED lights up red at the end of the failed trans-
mission process. The failed transmission may be caused
by radio interference (see “11 General information about
radio operation” on page 37). This may be caused be
the following:
• Receiver cannot be reached.
• Receiver is unable to execute the command (load
failure, mechanical blockade, etc.).
• Receiver is defective.