101568

SPECIFICATIONS

150,000
Propane Vapor Only

1.6
7.0

10 psi
Tank Pressure

13" WC
9.75" WC
550
3,450 RPM,
  1/8 HP
120 V/60 Hz
2.2
Direct Spark, Interrupted Type
.13/.15

27
36
36 x 14.5 x 20

Output Rating (BTU/Hr)
Fuel
Fuel Consumption

Gallons/Hour
Pounds/Hour

Supply Pressure To Regulator

Minimum (for purposes of
    input adjustment)
Maximum

Regulator Outlet Pressure

(Factory Preset)

Manifold Pressure
Hot Air Output  (CFM Approx)
Motor

Electric Input
Amperage
Ignition
Ignitor Gap (Inches)
Weight (Pounds)

Heater
Shipping

Size - L x W x H (Inches)

Power Cord
120 VAC

Motor

Green

Solenoid
Valve

L or 1

M or 3

S or 2

Red

On/Off
Switch

Safety
Control

G

V

VR ACR AC

Black

Black

White

Green

White

Black

Black

Black

White

Blue

Blue

Blue

Blue

Insulated
Connector

Thermal

Switch

Orange

Green

Ignitor

Fuse (If Equipped)

Relay

Position of
Leads May
Vary

Note: Some models do not
have a fuse.

WIRING

DIAGRAM

Summary of Contents for HP155A

Page 1: ...N BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER OWNERS MANUAL PROPANE CONSTRUCTION HEATER Man Reading Icon HSYMBOL2 Read all Safety Operating and Maintenance Instructions I...

Page 2: ...use which may be made of our heaters Check with your local fire safety authority if you have questions about heater use Other standards govern the use of fuel gases and heat producing products for specific uses Your local authorities can advise you about these Carbon Monoxide Poisoning Some people are more affected by carbon monoxide than others Early signs of carbon monoxide poisoning resemble th...

Page 3: ...by the State of California as a reproductive toxin under Proposition 65 For indoor use only Do not use heater outdoors Do not use heater in occupied dwellings or in living or sleeping quarters Do not use heater below ground level Propane gas is heavier than air If a leak occurs propane gas will sink to the lowest possible level Keep appliance area clear and free from combustible materials gasoline...

Page 4: ... Inlet Connector Lower Shell 1 Remove all packing items applied to heater for shipment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage If heater is damaged promptly inform dealer where you bought heater UNPACKING Fan Guard Figure 1 HP155A ...

Page 5: ...he combustion chamber This air is heated and provides a stream of clean hot air The Ignition System The direct spark ignitor DSI sends voltage to the ignitor The ignitor ignites the fuel and air mixture The Safety Control System This system causes the heater to shut down if the flame goes out Cool Air In Back Figure 2 Cross Section Operational View Hose Regulator Assembly Solenoid Valve DSI Nozzle...

Page 6: ...our local propane gas dealer will help you select the proper supply system The minimum surrounding air temperature rating for this heater is 20 F 29 C Temperature F At Tank WARNING Review and understand the warnings in the Safety Information Section pages 2 and 3 They are needed to safely operate this heater Follow all local codes when using this heater Hose Regulator Vent pointing down POL Fittin...

Page 7: ... Connector VENTILATION WARNING Follow the minimum fresh outside air ventilation require ments If proper fresh outside air ventilation is not provided carbon monoxide poisoning can occur Provide proper fresh outside air ventilation before running heater Provide a fresh air opening of at least four and one half 4 5 square feet Provide extra fresh air if more heaters are being used Example A 150 000 ...

Page 8: ...cord 51 to 100 feet long use 16 AWG rated cord 101 to 200 feet long use 14 AWG rated cord 4 Plug extension cord into a 120 volt 60 hertz three hole grounded outlet 5 Open propane supply valve on propane tank s slowly Note If not opened slowly excess flow check valve on propane tank may stop gas flow If this happens close propane supply valve and open again slowly 6 Turn on off switch to the ON pos...

Page 9: ... 5 of Standard for Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and or CAN CGA B149 2 Follow all local codes 2 Place plastic cover caps over brass fittings on inlet connector and hose regulator assembly 3 Store in dry clean and safe place Do not store hose regulator assembly inside heater combustion chamber 4 When taking heater out of storage always check inside of heater Insects...

Page 10: ...ther maintenance is needed for ignitor Fan IMPORTANT Remove fan from motor shaft before removing motor from heater The weight of the motor resting on the fan could damage the fan pitch 1 Remove upper shell see above 2 Use 1 8 hex wrench to loosen setscrew which holds fan to motor shaft 3 Slip fan off motor shaft 4 Clean fan using soft cloth moistened with kerosene or solvent 5 Dry fan thoroughly 6...

Page 11: ...egulator Outlet Pressure Factory Preset Manifold Pressure Hot Air Output CFM Approx Motor Electric Input Amperage Ignition Ignitor Gap Inches Weight Pounds Heater Shipping Size L x W x H Inches Power Cord 120 VAC Motor Green Solenoid Valve L or 1 M or 3 S or 2 Red On Off Switch Safety Control G V VR ACR AC Black Black White Green White Black Black Black White Blue Blue Blue Blue Insulated Connecto...

Page 12: ...68 33 2 1 31 12 26 43 9 32 10 11 38 29 20 21 6 7 6 5 3 30 37 34 Note Screws are standard hardware items 40 28 7 15 17 27 8 14 36 39 4 8 13 25 23 16 20 35 22 24 18 19 41 42 42 ILLUSTRATED PARTS BREAKDOWN HP155A ...

Page 13: ...h 1 24 03326 20 Screw 4 40 x 1 2 2 25 01086 30 Hex Nut 4 40 2 26 03326 48 Lower Shell Model HP155A 1 27 03326 18 Side Cover 1 28 01086 42 On Off Switch 1 29 01086 13 Relay Kit 1 30 01145 18 Screw 8 32 x 1 4 2 31 00529 44 Handle 1 32 00529 12 Screw 10 16 x 3 4 2 33 03326 17 Fan Guard 1 34 01086 12 Motor Relay Support Bracket Assy 1 35 00529 13 Strain Relief Bushing 1 36 A 03326 23 Power Cord 1 37 0...

Page 14: ...____________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ ___________________________________...

Page 15: ...____________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________ ___________________________________...

Page 16: ...IS NUMBER OVERSEAS OFFICES NETHERLANDS HOMELITE ATLANTIC HDQS Europe Africa and Middle East Haverstraat 24 2153 GB Nieuw Vennep The Netherlands AUSTRALIA HOMELITE PACIFIC LIMITED HEADQUARTERS 22 Terra Cotta Drive Blackburn 3130 Victoria Australia FRANCE HOMELITE S A R L Z I du Vert Galant Rue du Chateau Rue de la Garenne 95310 Saint Quen L Aumone France CANADIAN OFFICES HOMELITE CANADA LIMITED 185...

Reviews: