background image

13

3. Pump draining (Only applicable to HME020391N)

-  Remove the continuous drain hose from the unit. 

Replace the plastic cover of the continuous drain hose 

outlet tightly.

-  Attach the pump drain hose (Outer diameter: 1/4”; 

length: 16.4 ft) to the pump drain hose outlet. The 

insert depth should not be less than 0.59 inch. 

Lead the drain hose to the floor drain or a suitable 

drainage facility.

Reinstall the 

plastic cover

Pump drain  hose outlet 

(Only applicable to 

HME020391N)

Pump drain hose

-   Press 

Pump

 button to pump the water. When the 

bucket is full, the pump will start to work. It is normal 

that the pump makes loud noises at first 3~5 minutes 

of work. 

REMOVING THE COLLECTED WATER (CONT.)

Note:

 

-  Make sure the connection is tight and there is 

no leaking. 

-  If the pump hose drops when removing the 

bucket, you must install the pump hose to the 

unit before replacing the bucket into the unit.

-  The maximum pumping elevation is 16.4 ft.

Note:

 Do not use the pump when the outdoor 

temperature is equal to or less than 32°F (0°C), 

otherwise the water will freeze, causing the water 

hose to block up and the dehumidifier may be 

damaged. 

Operation

Pump hose drops

Reinstall  pump   

hose properly

Summary of Contents for HME020006N

Page 1: ...E020030N HME020006N HME020031N HME020391N Thank you for purchasing our quality appliance Please be sure to read the entirety of this user manual carefully prior to use of the product If you have any questions regarding the use of this product please call 1 800 898 3002 ...

Page 2: ... in In the event this product malfunctions or customer believes it is defective the customer should contact Customer Service and retain the defective product pending further instructions Defective product should be clearly marked or stored where it cannot be used again by mistake Failure to retain the product may impede hOme s ability to correct any legitimate problem and may limit the extent to w...

Page 3: ...Important Safety Instructions Parts Description Operation Care Cleaning Troubleshooting Warranty Warning Contact Us 6 7 8 9 13 14 15 16 16 16 TABLE OF CONTENTS ...

Page 4: ......

Page 5: ... appliance Congratulations Don t forget to register your product at homelabs com reg for updates coupons and other relevant information Although greatly appreciated product registration is not required to activate any warranty ...

Page 6: ... water 16 Place the dehumidifier on a level sturdy section of the floor 17 Do not cover the intake or exhaust openings of the dehumidifier with cloths or towels 18 Do not clean the appliance with any chemicals or organic solvent e g Ethyl acetate gasoline 19 This appliance is not intended for locations near to flammable or combustible gas 20 Care should be taken when using the dehumidifier in a ro...

Page 7: ...supply cord is damaged it must be replaced by qualified personnel Please contact Customer Service in order to avoid hazard Prior to cleaning or other maintenance the dehumidifier must be disconnected from the supply mains Do not install the dehumidifier in a location that may be exposed to combustible gas If combustible gas accumulates around the dehumidifier it may cause fire If the dehumidifier ...

Page 8: ...p Drain Hose 1pc Only for the dehumidifier with pump feature Power Cord Storage Bracket 1pc Water Level Window Handle both sides Air intake Grille Air Filter Continuous drain Hose Outlet Power Cord Storage Bracket Pump drain hose outlet Only applicable to HME020391N Power Cord Pump drain hose Power Plug Air Outlet Grille ...

Page 9: ...e dehumidifier with water in the bucket The dehumidifier may tip over and spill water Operation PLACEMENT SMART FUNCTIONS Auto Defrost When frost builds up on the evaporator coils the compressor will cycle off and the fan will continue to run until the frost disappears Auto Restart If the dehumidifier shuts off unexpectedly due to power being cut the dehumidifier will restart with the previous fun...

Page 10: ...e timer settings repeat the above operations Press or hold and buttons to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The selected time will register in 5 seconds and the system will automatically revert back to display the previous humidity setting To cancel a timer adjust the timer ...

Page 11: ...OST The appliance is on Defrost mode Operation CONTROL PANEL CONT LED display Shows the set humidity level from 35 to 85 or auto start stop time 0 24 while setting then shows the actual 5 accuracy room humidity level in a range of 30 RH Relative Humidity to 90 RH Relative Humidity Error Codes AS Humidity sensor error ES Temperature sensor error Protection Codes P2 Bucket is full or bucket is not i...

Page 12: ...ter hose to block up and the dehumidifier may be damaged water outlet Remove the plastic cover by counter clockwise rotation Female threaded end Water hose Note Make sure the connection is tight and there is no leaking Lead the water hose to the floor drain or a suitable drainage facility the drainage facility should be lower than the drain outlet of the dehumidifier Be sure to run the water hose ...

Page 13: ...Press Pump button to pump the water When the bucket is full the pump will start to work It is normal that the pump makes loud noises at first 3 5 minutes of work REMOVING THE COLLECTED WATER CONT Note Make sure the connection is tight and there is no leaking If the pump hose drops when removing the bucket you must install the pump hose to the unit before replacing the bucket into the unit The maxi...

Page 14: ...the bucket Clean the bucket with water and mild detergent every two weeks 3 Clean the air filter Clean the filter with potable water at least once every 30 days 4 Storing the dehumidifier Store the dehumidifier when it will not be used for a long time After turning off the dehumidifier wait one day until all water in the internal of the dehumidifier flows into the bucket and then empty the bucket ...

Page 15: ...front or back of the dehumidifier The humidity level may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 41 F 5 C There is a kerosene heater or something giving off water vapor in the room The air filter is clogged The dehumidifier is tilted instead of upright as it should be The floor surface is not level This is normal T...

Page 16: ...you register your product on our website homelabs com reg Although greatly appreciated the product registration is not required to activate any warranty and product registration does not eliminate the need for the original proof of purchase The warranty becomes void if attempts at repair are made by non authorized third parties and or if spare parts other than those provided by hOme are used You m...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ... 2020 hOmeLabs LLC 37 East 18 Street 7th Floor New York NY 10003 1 800 898 3002 help homelabs com homelabs com help All rights reserved hOme Printed in China For Household Use Only ...

Reviews: