background image

16

17

Note:

Slight temperature variations may be observed 

(+/- 0.3 – 0.5°F or +/- 0.2 – 0.3°C) in consecutive
measurements. This is common to all types of thermometers.

• Always take the temperature in the same ear, as readings

may differ from one ear to another.

• The ear must be free from excessive earwax buildup or

other obstructions in order to take an accurate reading.
Note that you should never attempt to clean inside ears,
however, as this may result in damage to the eardrum or
surrounding tissues. Remove only excess earwax that can
be reached with a washcloth. Consult a physician if you
suspect excess earwax is present within the ear.

• Ear temperatures may be influenced by external factors,

including:

• An ear that has been rested upon or covered
• General exposure to extreme hot or cold temperatures
• Recent bathing or swimming
• Use of hearing aids or ear plugs 

It is recommended that measurement occur at least 20
minutes after these circumstances are no longer present.

• This ear thermometer is for use in human ears only. Do not

use for oral, rectal, or axillary temperature measurement.

SPECIAL SITUATIONS IN WHICH THE EAR
THERMOMETER SHOULD NOT BE USED

• Pain of any kind is noted during use.
• Blood or drainage is present in the external ear canal.

• Deformities of the ear canal or face exist that prohibit the

thermometer from being properly inserted into the ear canal.

• Ear medication or ear drops have been placed in the ear canal.
• Ear infection of any kind is present.
• Individual has been bathing or swimming, as this may lead to

injury of ear tissue, as well as inaccurate readings.

CARE, MAINTENANCE & CLEANING

• Clean the unit carefully with a soft, dry cloth. Do not use any

gas, strong detergent, or solvents to clean the device.

• Clean the waterproof probe with a cotton swab moistened

with rubbing alcohol. 

• Never attempt to insert any object into the probe tip.
• Do not immerse the unit in water as this will result in damage

to the unit. Waterproof portion of unit is limited to probe tip.

• Do not subject the ear thermometer to extreme temperatures,

humidity, moisture, and direct sunlight.

• Do not disassemble the ear thermometer. If in need of repair,

refer to the warranty section of this manual.

• Do not subject the ear thermometer to extreme shocks (do

not drop on floor).

• When not in use, keep thermometer in its storage case and

out of the reach of children. If the thermometer will not be
used for three months or more, remove battery.

• The thermometer is calibrated by the manufacturer. If you

have questions about the use of your thermometer, please
contact HoMedics Consumer Relations at 1-800-466-3342.

Summary of Contents for THERA-P TE-120

Page 1: ...señado fabricado aprobado y o autorizado o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI IMPLÍCITA INCLUYENDO NINGUNA GARANTÍA DE COMERCIALIZACIÓN O APTITUD NI NINGUNA OTRA OBLIGACIÓN POR PARTE DE LA COMPAÑÍA CON RESPECTO A PRODUCTOS CUBIERTO...

Page 2: ...aking a temperature Thermometer should be used in a dry ear canal Gentle force should be used when inserting the probe into the ear Excessive force may injure the ear canal or eardrum Do not expose the monitor to extreme high or low temperatures very high humidity or direct sunlight Handle product with care and avoid dropping Do not immerse the unit in water or other liquids Do not disassemble or ...

Page 3: ...rate to 0 4 F 0 2 C See Product Specifications p 19 for more information Deluxe One Second Ear Thermometer How does this product work This ear thermometer is a delicate and high tech electronic device designed to measure body temperature This unit provides accurate and reliable temperature readings by detecting infrared heat from the eardrum and surrounding tissue The thermometer takes 512 scans o...

Page 4: ...temperature to determine your normal temperature range in order to determine when a fever is present Classification of a temperature as a fever also varies by age This product is not intended as a substitute for consultation with a physician Contact your physician if you feel an illness is present with or without a fever A physician should be consulted if any of the following conditions are presen...

Page 5: ...ult temperature of 00 after battery power is restored and until a measurement is taken When the low battery symbol appears on the display the battery should be replaced When the low battery symbol appears with the Lo symbol Figure 5 the battery must be replaced in order for the ear thermometer to function NOTE Do not discard used lithium batteries in trash Please turn in at an official collection ...

Page 6: ...commended for general use in order to preserve battery life Modes can be changed at any time before or after measurement Do not change modes during measurement as the accuracy of the reading may be affected MEMORY RECALL This thermometer will automatically store the last 20 measurements in memory The most recent reading will automatically display when the unit is turned on Each new temperature rea...

Page 7: ... of the ear thermometer into the ear canal within two seconds Figure 8 It is important that the probe tip be well positioned within the ear canal Measurement time for the actual reading is approximately one second 6 A beep will indicate the end of the measurement Results of the temperature measurement will be displayed In NIGHT MODE the display will illuminate for five seconds and the thermometer ...

Page 8: ...onds between readings to ensure accuracy Use the ear thermometer at room temperature as extremes in environmental temperature can impact accuracy Unit should be stored at room temperature Before use the unit must be at room temperature for at least 30 minutes Clean the waterproof probe with a cotton swab moistened with rubbing alcohol between readings Always keep rubbing alcohol cleaners away from...

Page 9: ... drainage is present in the external ear canal Deformities of the ear canal or face exist that prohibit the thermometer from being properly inserted into the ear canal Ear medication or ear drops have been placed in the ear canal Ear infection of any kind is present Individual has been bathing or swimming as this may lead to injury of ear tissue as well as inaccurate readings CARE MAINTENANCE CLEA...

Page 10: ...C Low battery warning Battery power is low Replace battery see Inserting and Replacing Batteries Low battery warning with Lo symbol Battery power is too low for the thermometer to function Replace battery immediately see Inserting and Replacing Batteries PRODUCT SPECIFICATIONS Model Number Model Number TE 120 Power Source DC 3 Volt lithium battery CR2032 Battery Life 1 700 Measurements in day mode...

Page 11: ...fications is not covered under this warranty THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY HOMEDICS SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL CONSEQUENTIAL OR ...

Page 12: ...edida de la temperatura pg 34 Situaciones especiales en las cuales no debe usarse en termómetro auricular pg 36 Cuidado mantenimiento y limpieza pg 37 22 23 IMPORTANTES INSTRUCCIONES DESEGURIDAD Cuando utiliza su termómetro auricular siempre se deben seguir ciertas precauciones básicas Por favor lea y aténgase a todas las instrucciones y advertencias antes de usar este producto Guarde estas instru...

Page 13: ...mente fiebre Termómetro Auricolar Deluxe Lectura en Un Segundo Cómo funciona este artículo Este termómetro auricular es un dispositivo delicado y de alta tecnología diseñado para medir la temperatura corpórea Esta unidad proporciona lecturas de temperatura precisas y confiables registrando el calor infrarrojo del tímpano y del tejido que lo rodea Este termómetro escanéa 512 veces el tímpano y el t...

Page 14: ...a clasificación de la temperatura como fiebre también varía con la edad Este producto no es entendido como un sustituto de una consulta médica Si cree que está enfermo con o sin fiebre consulte a su médico Es necesario consultar al médico si se presenta cualquiera de las siguientes condiciones Vómito diarrea cambios en la respiración actividad o en el apetito irritabilidad estado letárgico o somno...

Page 15: ... mientras la unidad está encendida y presione inmediatamente el botón MEMORY para cambiar entre las escalas Una vez 28 29 Figura 5 Aviso de Batería Baja seleccionada la escala deseada presione el botón Scan para tomar una lectura nueva o dejar que la unidad se apague automáticamente y luego enciéndala otra vez para observar memoria USANDO EL MODO DAY Y NIGHT día y noche El Night Mode modo de noche...

Page 16: ... dos segundos RECUPERAR MEMORIA EN PANTALLA Este termómetro almacena automáticamente las últimas 20 medidas en memoria Cuando se enciende la unidad la lectura más reciente aparece automáticamente en pantalla Cada nueva lectura de temperatura ingresa en memoria como el récord más reciente En el modo de memoria aparece una flecha a la derecha con el número del récord en memoria como se indica abajo ...

Page 17: ... C Si la medida queda debajo de este rango la unidad indica Lo Fig 10 Si queda arriba de este rango la unidad indica Hi Fig 11 5 Inserte la punta de la sonda del termómetro auricular en el canal auricular en menos de dos segundos Fig 8 Es importante posicionar bien la punta de la sonda en el canal auricular El tiempo de medida de la lectura es de aproximadamente un segundo 6 Un pitido indicará el ...

Page 18: ... libre de depósitos excesivos de cera y otras obstrucciones Sin embargo observe que usted no debería tratar nunca de limpiar el interior del oído pues esto podría resultar en daños al tímpano o al tejido que lo rodea Quite sólo el exceso de cera que puede alcanzarse con un paño Consulte a su médico si sospecha tener exceso de cera en el oído La unidad indica Err si la temperatura operativa no qued...

Page 19: ... de Relaciones con el consumidor de HoMedics al teléfono 1 800 466 3342 Las temperaturas del oído pueden sufrir la influencia de factores externos incluyendo El oído sobre el cual se ha descansado o ha estado cubierto Exposición general a temperaturas extremas calientes o frías Baño o natación recientes Uso de dispositivos auxiliares para oír o tapones para el oído Se recomienda tomar la medida no...

Page 20: ... de la temperatura se encuentra por debajo del rango de medida debajo de 50 F 10 C Rango Operacional El rango de medida es de 50 F 122 F 10 50 C Si tiene o sospecha tener cualquier problema de salud póngase en contacto con su médico La sonda no está posicionada correctamente en el oído Asegúrese de que la sonda esté posicionada correctamente en la apertura del canal auricular La sonda impermeable ...

Reviews: