HoMedics THERA-P BPA-200 Manual Download Page 2

2

1

Important Notes Regarding Your 
Blood Pressure Measurement  . . . . . . . . . . . . .23
Recalibration Service  . . . . . . . . . . . . . . . . . . . .25
Care, Maintenance & Cleaning . . . . . . . . . . . . .26
Potential for Radio/Television Interference  . .28
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . .29
Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . .30
Lifetime Limited Warranty  . . . . . . . . . . . . . . . .31

TABLE OF CONTENTS

INTRODUCTORY INFORMATION:
Important Product Notices and Safety
Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
About Blood Pressure  . . . . . . . . . . . . . . . . . . . .5

What is Blood Pressure?
Why Measure Your Blood Pressure?

Blood Pressure Standard  . . . . . . . . . . . . . . . . . .5
How This Blood Pressure Monitor Works . . . . .7

USAGE INFORMATION:
Name/Function of Each Part . . . . . . . . . . . . . . . .8
Display Explanations  . . . . . . . . . . . . . . . . . . . . .9
Installing Batteries  . . . . . . . . . . . . . . . . . . . . . .11
Using the AC Adapter  . . . . . . . . . . . . . . . . . . . .12
Date & Time Set Procedure  . . . . . . . . . . . . . . .13
Applying the Cuff  . . . . . . . . . . . . . . . . . . . . . . .14
Measurement Procedure  . . . . . . . . . . . . . . . . .17
Risk Category Indicator  . . . . . . . . . . . . . . . . . .20
Recalling Values from Memory  . . . . . . . . . . . .22
Clearing Values from Memory  . . . . . . . . . . . . .23

Summary of Contents for THERA-P BPA-200

Page 1: ...do al no cumplimiento del mantenimiento recomendado por el fabricante da os durante el transporte robo descuido vandalismo condiciones clim ticas p rdida de uso en el per odo durante el cual el produc...

Page 2: ...mportant Product Notices and Safety Instructions 3 About Blood Pressure 5 What is Blood Pressure Why Measure Your Blood Pressure Blood Pressure Standard 5 How This Blood Pressure Monitor Works 7 USAGE...

Page 3: ...h arrythmias This device may have difficulty determining the proper blood pressure for individuals with diabetes poor circulation of blood kidney problems or for users who have suffered from a stroke...

Page 4: ...high blood pressure are very common High blood pressure dangerously correlates with cardiovascular diseases Therefore blood pressure monitoring is important for identifying those at risk BLOOD PRESSUR...

Page 5: ...ur systolic pressure diastolic pressure and pulse readings Based upon your measurement results the monitor s Risk Category Indicator will alert you if your reading falls into the pre hypertension stag...

Page 6: ...Indicator Display Symbols START STOP No Symbol START STOP Pulse Rate Measurement Error Measure again Wrap the cuff correctly and keep arm steady during measurement Measurement Error Measurement resul...

Page 7: ...he back of the unit as shown below 2 Please use only the AC adapter included with this monitor AC Adapter Input 120V 60Hz Output 12V DC 500mA Connect AC adapter here INSTALLING BATTERIES Note It is re...

Page 8: ...ner Press the Set button again to confirm the entry and the screen will show a blinking number representing the minutes 3 Change the time and date as described in Step 2 above using the button to chan...

Page 9: ...d of your elbow on the inside of your right arm Identify where the pulse can be felt the strongest This is your main artery Very Important Proper cuff size is critical to accurate measurement This cuf...

Page 10: ...g the measurement do not talk or move your arm or hand muscles See page 23 for additional notes regarding your blood pressure measurement 1 Press the User Select Button to choose User 1 or User 2 Afte...

Page 11: ...lso press the START STOP button to turn the unit off 2 To interrupt the measurement you may press the START STOP recommended M User Select or Date Time Set buttons The cuff will deflate immediately af...

Page 12: ...you consult your physician START STOP 1 Press the User Select button 2 Choose User 1 or User 2 3 Press the M button to access the memory 4 The monitor will first display the calculated average applied...

Page 13: ...ouch cuff or monitor during measurement procedure It is suggested that you take your measurements at the same time each day and use the same arm for consistency Users should wait a minimum of 5 minute...

Page 14: ...l information contact HoMedics Consumer relations at 1 800 466 3342 CARE MAINTENANCE CLEANING 1 Clean the blood pressure monitor body and cuff carefully with a slightly damp soft cloth Do not press Do...

Page 15: ...nstalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Page 16: ...mbol shown on display Inflation pressure exceeding 300 mmHg Switch the unit off then measure again E3 error symbol shown on display Data error Remove and reload the batteries CA Appears on display Rec...

Page 17: ...intenance transportation damage theft neglect vandalism or environmental conditions loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair or any other...

Page 18: ...r qu medir la presi n sangu nea Est ndar de presi n sangu nea 37 C mo funciona este monitor de presi n sangu nea 39 INFORMACI N DE USO Nombre Funci n de cada pieza 40 Explicaciones de la pantalla 41 I...

Page 19: ...Este dispositivo puede tener dificultad para determinar la correcta presi n sangu nea para las personas con diabetes mala circulaci n trastornos renales o usuarios que han sufrido una apoplej a La pan...

Page 20: ...ra peligrosa con las enfermedades cardiovasculares Por lo tanto controlar la presi n sangu nea es importante para identificar a las personas en riesgo EST NDAR DE PRESI N SANGU NEA El U S Department o...

Page 21: ...ca presi n diast lica y de pulso En base a los resultados de la medici n el Indicador de Categor a de Riesgo del monitor lo alertar si su lectura se encuentra en las categor as prehipertensi n etapa 1...

Page 22: ...opera el monitor S mbolo de pilas bajas aparece cuando tiene que cambiar las pilas S mbolo de pulso muestra los pulsos por minuto Importante Bolet n de Salud Vea la p gina 53 para obtener m s informac...

Page 23: ...que se suministran son de prueba nicamente puede que se descarguen antes que las pilas que compra en la tienda Reemplace las pilas en pares Saque las pilas cuando la unidad no est en uso durante much...

Page 24: ...n meros y el bot n Set para confirmar las definiciones 4 Reaparecer un 0 cuando el monitor de presi n sangu nea est listo para medir nuevamente presione el bot n hora intermitente aumento de la hora c...

Page 25: ...brazalete con otra circunferencia P ngase en contacto con Relaciones con el Consumidor de HoMedics para ver tama os adicionales de brazalete 48 47 3 Retire la ropa apretada de la parte superior del b...

Page 26: ...cansado ni extenuado cuando realiza la medici n Durante la medici n no hable ni mueva los m sculos del brazo ni la mano Vea la p gina 56 para obtener notas adicionales con respecto a la medici n de su...

Page 27: ...el bot n de START STOP COMENZAR DETENER para apagar la unidad 2 Para interrumpir la medici n puede presionar los botones START STOP COMENZAR DETENER recomendado M Selecci n del usuario o Configurar f...

Page 28: ...as 5 Cada vez que presiona el bot n M se recuperar una lectura previa La ltima lectura ser la primera en recuperarse START STOP START STOP START STOP STA ST BOLET N DE SALUD IMPORTANTE Este dispositiv...

Page 29: ...azalete ni el monitor durante el procedimiento de medici n Le sugerimos que tome las mediciones todos los d as a la misma hora y en el mismo brazo para establecer una coherencia Los usuarios deber n e...

Page 30: ...IEZA 1 Limpie el cuerpo del monitor de presi n sangu nea y el brazalete con cuidado con un pa o suave apenas h medo No lo apriete No lave el brazalete ni utilice un limpiador qu mico para limpiarlo Nu...

Page 31: ...ndo las instrucciones puede causar interferencia peligrosa en las comunicaciones de radio Sin embargo no hay garant as de que no se produzca interferencia en una instalaci n en particular Si el produc...

Page 32: ...Aparece el s mbolo de error E1 en la pantalla Irregularidad en el circuito de aire Puede que el tubo del brazalete no est correctamente conectado al monitor Verifique la conexi n del brazalete Mida nu...