background image

IMPORTANT PRODUCT NOTICES AND 

SAFETY INSTRUCTIONS

•  This is a home healthcare product only and is solely intended 

for sports and recreational use. It is not intended to serve as a 

substitute for the advice of a physician or medical professional.

•  The readings from this pulse oximeter are for reference only. 

Consult a healthcare professional for interpretation of your 

pulse oximeter measurements. Contact a physician if you 

have or suspect any medical problem. Do not change your 

medications without the advice of your physician or healthcare 

professional.

•  The pulse display is not suitable for checking the frequency of 

pacemakers.

•  Use the pulse oximeter only for its intended use.
•  Please keep this device away from children. Small parts such 

as battery and battery door could be hazardous if swallowed.

•  The lanyard could cause strangulation in conditions when 

twisted around the neck.

•  This pulse oximeter should not be used where alarms are 

required when taking measurements. 

•  For greatest accuracy, wait 10 minutes after exercising, 

bathing, eating, drinking beverages with alcohol or caffeine, or 

smoking to measure blood oxygen level.

•  Use only 3.6V “

½ AA” Lithium battery for power supply.   

•  If there is any damage to the product, including blurring of the 

LCD display, please contact HoMedics Consumer Relations at 

1-800-466-3342.

•  Do not use cellular phones or other radio frequency producing 

devices near the working device as it may interfere with proper 

operation of the pulse oximeter.

•  Not for use by or on persons under the age of 18 years old.

CARE, MAINTENANCE & CLEANING

•  Use a cotton swab with isopropyl alcohol solution (70%) to clean 

the inside of the finger sleeve or the outside of the unit.

•  Do NoT use any other liquid or sprays on the oximeter for 

cleaning purposes.

•  Under normal usage conditions, this device does not require 

calibration or technical maintenance other than infrequent 

replacement of the battery.

•  Leaky batteries can damage the unit. Remove the battery 

when the unit will not be used for a long time.

•  This product should only be used on the fingers.
•  Do NoT disassemble this device. If in need of repair, refer to 

the warranty section of this manual.

•  Do NoT use the product if the finger sleeve changes color or 

is no longer able to secure on finger.

•  Do NoT subject this device to extreme shocks (do not drop 

on floor).

•  Do NoT drop or insert any object into any opening.
•  Do NoT immerse the unit in water as this will result in damage 

to the unit.

•  Do NoT subject this device to extreme temperatures, 

humidity, moisture, or direct sunlight. Protect from dust.

•  If the unit is stored near freezing, allow it to acclimate to room 

temperature before use.

•  This monitor may not meet its performance specifications if 

stored or used outside of these temperature and humidity 

ranges:

TROUBLESHOOTING

If any abnormality arises during use, please check the following points:

ABOUT PULSE OXIMETERS

This pulse oximeter uses optimetrix™ technology, which utilizes 

revolutionary optical sensor technology to measure both blood 

oxygen saturation ( Spo

2

%) levels and pulse rate. By placing the 

finger into the sleeve and one-touch of a button, this device will 

send both red and infrared lights into the skin to collect data and 

display your blood oxygen and pulse rate.

NAME/FUNCTION OF EACH PART

Finger Sleeve

Multi-directional 

Button

LCD Display

Battery 

Compartment

Other Accessories Included:
•  1 “½ AA” Lithium Battery 

(included in the unit)

•  Storage Pouch
•  Lanyard

Storage Environment 

Temperature

-4°F ~ 158°F

(-20°C ~ 70°C)

Humidity: Less than 95% 

non-condensing

Operation Environment 

Temperature
39°F ~ 107°F

(4°C ~ 42°C)

Humidity: Less than 95% 

non-condensing

DISPLAY EXPLANATIONS

Signal 

Strength 

Indicator

Pulse Rate

Blood oxygen 

Level

Sensor Off Indicator: Appears when the finger 
has been removed from the finger sleeve.

Weak Battery Symbol: Flashes when battery 
should be replaced.

Pulse Rate: Shows the pulse rate per minute.

/

START

STOP

3

/

START

STOP

3

SYMPTOMS

POSSIBLE 

CAUSES

CORRECTION

Pulse Rate or 

Spo

2

 is not 

appearing.

Position of the 

finger is not 

correct.

Reposition the finger into the 

correct position and measure 

again.

The pulse 

oximeter will 

not power on.

Battery has 

run down.

Replace the battery with a 

single 3.6V “

½ AA” Lithium 

battery.

Screen 

orientation is 

upside down.

Viewing angle 

needs to be 

adjusted.

Press the 

Multi-directional 

button 

 for up to 2 seconds 

and the screen will rotate 180°.

LIMITED TWO YEAR WARRANTY

HoMedics sells its products with the intent that they are 

free of defects in manufacture and workmanship for a 

period of two years from the date of original purchase, 

except as noted below. HoMedics warrants that its prod-

ucts will be free of defects in material and workmanship 

under normal use and service. This warranty extends 

only to consumers and does not extend to Retailers.
To obtain warranty service on your HoMedics product, 

contact a Consumer Relations Representative by tele-

phone at 1-800-466-3342 for assistance. Please make 

sure to have the model number of the product available.
HoMedics does not authorize anyone, including, but 

not limited to, Retailers, the subsequent consumer 

purchaser of the product from a Retailer or remote 

purchasers, to obligate HoMedics in any way beyond 

the terms set forth herein. This warranty does not cover 

damage caused by misuse or abuse; accident; the 

attachment of any unauthorized accessory; alteration to 

the product; improper installation; unauthorized repairs 

or modifications; improper use of electrical/power 

supply; loss of power; dropped product; malfunction 

or damage of an operating part from failure to provide 

manufacturer’s recommended maintenance; transporta-

tion damage; theft; neglect; vandalism; or environmental 

conditions; loss of use during the period the product is 

at a repair facility or otherwise awaiting parts or repair; 

or any other conditions whatsoever that are beyond the 

control of HoMedics. This warranty is effective only if 

the product is purchased and operated in the country in 

which the product is purchased. A product that requires 

modifications or adoption to enable it to operate in 

any other country than the country for which it was 

designed, manufactured, approved and/or authorized, 

or repair of products damaged by these modifications is 

not covered under this warranty.
THE WARRANTY PROVIDED HEREIN SHALL BE THE 

SOLE AND EXCLUSIVE WARRANTY. THERE SHALL 

BE NO OTHER WARRANTIES EXPRESS OR IMPLIED 

INCLUDING ANY IMPLIED WARRANTY OF MERCHANT-

ABILITY OR FITNESS OR ANY OTHER OBLIGATION 

ON THE PART OF THE COMPANY WITH RESPECT TO 

PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS 

SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL, 

CONSEQUENTIAL OR SPECIAL DAMAGES. IN NO 

EVENT SHALL THIS WARRANTY REQUIRE MORE THAN 

THE REPAIR OR REPLACEMENT OF ANY PART OR 

PARTS WHICH ARE FOUND TO BE DEFECTIVE WITHIN 

THE EFFECTIVE PERIOD OF THE WARRANTY. NO 

REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS 

FOR DEFECTIVE MATERIALS ARE NOT AVAILABLE, 

HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT 

SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACE-

MENT.
This warranty does not extend to the purchase of 

opened, used, repaired, repackaged and/or resealed 

products, including but not limited to sale of such 

products on Internet auction sites and/or sales of 

such products by surplus or bulk resellers. Any and all 

warranties or guarantees shall immediately cease and 

terminate as to any products or parts thereof which are 

repaired, replaced, altered, or modified, without the prior 

express and written consent of HoMedics.
This warranty provides you with specific legal rights. 

You may have additional rights which may vary from 

state to state. Because of individual state regulations, 

some of the above limitations and exclusions may not 

apply to you.
For more information regarding our product line in the 

USA, please visit: www.homedics.com.

HoMedics and Optimetrix are registered trademarks of HoMedics, LLC.

©2012 HoMedics, LLC. All Rights Reserved.

IB-PX100

PX-100 Pulse Oximeter: Part# 90350000

Cat# 10957800

REPLACING BATTERY

1.  The battery compartment is located 

on the top of the unit. Remove battery 

cover by pressing down and sliding 

the battery cover off. (fig. 1) 

2.  Install or replace the battery according 

to the polarity indicator located inside 

the compartment. Use only 3.6V  

½ AA” sized Lithium batteries. (fig. 2)

3.  Replace the battery cover by inserting 

it back into place. (fig. 3)

Replace the batteries if:
•  The weak battery symbol appears on 

the display.

•  Nothing appears on the display after 

the finger is inserted into the sleeve 

and the button is pressed.

Note: Batteries are hazardous waste. Do 

not dispose of them together with the 

household garbage.

Fig. 2

Fig. 3

Fig. 1

MEASUREMENT 

PROCEDURE

If you are using this pulse oximeter for the 

first time, please remove the pull tab from 

the battery door.
1.  Hold the pulse oximeter so that the 

picture of the finger nail on the finger 

sleeve is facing up.

2.  Gently place any finger into the finger 

sleeve as shown in the diagram  

(fig. A). Slightly press on the sides of the 

finger sleeve to ease the finger inside.

3.  Turn the hand over so that the LCD 

screen is now facing you and your 

finger is pointed up (fig. B).

4.  Push the 

Multi-directional button 

 

to initiate readings (fig. C).

5.  Continue to vertically hold the pulse 

oximeter to enable readings 

6.  To change the direction of the LCD 

screen display by 180°, press the 

Multi-

directional button 

 for up to two (2) 

seconds.

Note:
•  Signal strength should be greater than 

one bar to indicate a proper reading  

(fig. D).

•  In the event of weak signal strength, 

please switch fingers and/or hand and 

try again.

•  For greatest accuracy, limit hand motion 

during measurement.

•  When the finger is removed, the pulse 

oximeter will turn off after 10 seconds. 

Fig. A

Fig.B

Fig.C

Fig.D

For service or repair, 

do not return this unit 

to the retailer. Contact 

HoMedics Consumer 

Relations at:

Email:

cservice@ 

homedics.com

Phone:

1-800-466-3342

Business Hours:

8:30am-7pm ET

Monday-Friday

Distributed by

®

Distributed by

®

Distribuido por

HoMedics, LLC 

3000 Pontiac Trail 

Commerce  

Township, MI 

48390

Printed in China

    PRODUCT SPECIFICATIONS

Effective Measuring Range
Saturation

70 to 99%

Pulse Rate

40 to 250 bpm

Resolution 

1 digit

Accuracy 
Saturation (70%-99%)

±2% or ±2 digits

Pulse Rate

±3% or ±3 digits

Display
Saturation

2 characters

Pulse Rate

3 characters

Signal Indications:

Flashing Heart Icon, Sensor ‘off’ 

and Signal intensity strength, 

battery indication - near empty 

Power Requirements

3.6V “½ AA” size Lithium battery

Battery life

up to 300 Hours

        Type BF Applied Part        Spot Measurement No alarms

SpO2

Pl

ea

se

 Ta

ke A Moment

 N

ow

Register 

Your Product At:

 www.homedics.com/register

Your valuable input regarding this 

product will help us create  

the products you will  

want in the future. 

Deluxe Pulse Oximeter

Note: When changing the orientation of the screen, the pulse 

rate will be shown on the top near the blinking Pulse Rate Icon, 

and the blood oxygen level will be shown on the bottom of the 

LCD display.

Spo

2

Reviews: