Installing Instructions

1. Remove demineralization cartridge from packaging and 

let it soak in water for 10 minutes.

2. Remove the tank from humidifier base.  (Fig. 3)
3. 

Place 1 demineralization cartridge down into left 
side matching slot in the humidifier base.

 (Fig 9)

4. Place the tank back on the base, making sure the tank is 

firmly seated. (Fig. 7)

Cleaning and Care

CAUTION: 

Before cleaning the unit, turn power off and 

unplug unit from the outlet.

Tank Cleaning

Remove the water tank from the humidifier base by 
lifting it by the handle from the main unit. Unscrew 
the tank cap; wipe the tank with a soft cloth then 
rinse it with clean water. (Fig. 10)
Suggestion: Clean the water tank once every two to 
three weeks, depending on your water conditions.

Ultrasonic Nebulizer Cleaning

Put small amount of mild dish soap on the surface 
of the ultrasonic nebulizer, then pour in some water 
and soak for 5 minutes. Brush clean with soft bristle 
brush (not included) and rinse. (Fig. 11)

Surface Cleaning

Clean the surface of the unit with a clean damp  
soft cloth. (Fig. 12)

Fig.10 

Fig.12

Fig.11

PROBLEM

POSSIBLE CAUSE

SOLUTION

Power Light is off

• Unit is not plugged in

• No power at unit

• Plug unit in

• Press the POWER button 

to turn the power on

• Check circuits, fuses, try a 

different outlet

SoundSpa will not  

turn on

• Unit is not plugged in

• Volume is down too low

• No sound selection has 

been made

• Sleep Mode cycle is over

• Plug unit in

• Turn the SOUNDSPA 

POWER/VOLUME knob 

clockwise to increase 

volume

• Press a sound selection 

button to choose a sound

• Use the SOUNDSPA 

POWER/VOLUME knob to 

turn the SoundSpa OFF, 

then back ON again.

Peculiar Odor

• If new unit

• If unit is in use, the odor 

may be a dirty tank or old 

tank water

• Open the water tank cap 

and keep it in a shady and 

cool place for 12 hours

• Empty the old water,  

clean the tank and fill  

with clean water

Excessive Noise

• Unit is not level

• Low water level

• Place unit on a flat,  

even surface

• Check the water level. Refill 

the tank if the water is low

White Dust Accumulation • Hard water used

• Demineralization Cartridge 

needs replacement

• Use distilled water and a 

Demineralization Cartridge

• Replace Demineralization 

Cartridge

Troubleshooting

Fig. 8

Fig. 9 

Summary of Contents for HUM-PED1

Page 1: ...Mist Humidifier with Built In SoundSpa El manual en espa ol empieza a la p gina 13 P l e ase Take A Moment N o w Register Your Product At www homedics com register Your valuable input regarding this...

Page 2: ...valids or disabled persons Use this appliance only for its intended use as described in this manual Do not use attachments not recommended by HoMedics specifically any attachments not provided with th...

Page 3: ...of reach from children Do not allow children to use the appliance without supervision Unique Features and Specifications Ultrasonic Technology This humidifier uses ultrasonic high frequency technology...

Page 4: ...ver turn the SOUNDSPA POWER VOLUME knob counter clockwise to the OFF position then back ON When the SoundSpa is turned back on the default SUMMER NIGHT sound will begin playing To return to normal ope...

Page 5: ...ent the harder your water is the greater the potential for white dust The white dust is not caused by a defect in the humidifier but is due only to minerals suspended in the water Demineralization Car...

Page 6: ...n the surface of the unit with a clean damp soft cloth Fig 12 Fig 10 Fig 12 Fig 11 PROBLEM POSSIBLE CAUSE SOLUTION Power Light is off Unit is not plugged in No power at unit Plug unit in Press the POW...

Page 7: ...onditions whatsoever that are beyond the control of HoMedics This warranty is effective only if the product is purchased and operated in the country in which the product is purchased A product that re...

Reviews: