3.  Input your age. The age figure of the previous setting will be displayed on LCD and 

it will be blinking. 

Press (

)/(

) button to increase /decrease the displayed age. Press (MODE) button to 

confirm displayed age. 

4. Input your gender. The gender icons will be blinking. 

Press (

)/(

) button to toggle between male and female icons.

Press (MODE) button to confirm all the settings with 1 long beep.

5.   “    ” icon will be displayed. Step on the scale with bare feet. Stand still while the unit 

measures your weight. The weight will display for 2 seconds. Remain on the scale.

6.  Then it will start to measure body fat. The measurement pattern will be shown on the

display during BFA measurement. 

7.  The BFA measurement finishes with 1 long beep. The fat percentage, weight, age, and 

sex will be shown on the display for 4 seconds, then turn off. 

Battery Installation

1.  Uses one 9-Volt alkaline battery (not included). 
2.  Remove Battery Compartment Cover on the bottom of the scale and insert 

battery into the 9-Volt battery snap.

3.  The scale needs to be initialized before first use or after battery replacement: 

Press lightly on the scale platform. The display will show “

OOOO

”, then the scale 

will automatically turn off. Your scale is now ready for use.

4.  Replace the battery when “

Lo

” is displayed.

5.  Remove the battery if the product is not used for a long time.

Instructions for Use

Weight Reading Only

1.  Select (lb/in) or (kg/cm) by the slide switch on the bottom of the scale.
2.  Place the Analyzer/Scale on a firm, flat surface to achieve best accuracy.
3.  Step onto the scale; stand still while the scale computes your weight. 

4.  Your weight will be shown on the LCD display as shown below. 

5.  The scale turns off by itself after use.

Body Fat Measuring Operation

You must have bare feet to make this measurement. To get the most accurate and 
consistent reading, wipe your feet with a damp cloth, leaving them slightly moist before
stepping on scale. You must remove your shoes and socks before proceeding with
Step 5. 
You have approximately 5 seconds to step on the scale in step 5 before it
automatically shuts-off to conserve the battery. 
1.  Before stepping on scale. Press (ON) button to enter BFA mode. The height figure 

of the previous setting will be displayed on LCD. The height figure will be blinking.

2.  Input your height. Press (

)/(

) button to increase /decrease the displayed height.

Press (MODE) button to confirm displayed height.

WEIGHT

LB

HEIGHT

"

'

AGE

AGE

WEIGHT

LB

MODE

%

LB

R

MODE

   

 

 

 

     

 

 

 

     

 

 

 

             

 

 

 

   

Summary of Contents for Body Fat Monitor

Page 1: ... Válida únicamente en los EE UU HoMedics Inc garantiza este producto contra defectos en material y mano de obra mientras esté en vida el comprador original a partir de la fecha original de compra con las excepciones que se detallan a continuación Esta garantía de producto de HoMedics no cubre daños causados por un uso inadecuado abuso accidente la conexión de accesorios no autorizados la alteració...

Page 2: ...splay will show OOOO then the scale will automatically turn off Your scale is now ready for use 4 Replace the battery when Lo is displayed 5 Remove the battery if the product is not used for a long time Instructions for Use Weight Reading Only 1 Select lb in or kg cm by the slide switch on the bottom of the scale 2 Place the Analyzer Scale on a firm flat surface to achieve best accuracy 3 Step ont...

Page 3: ... BFA Body Fat Analyzer mode it will automatically turn off in 10 seconds 9 The Body Fat Display Graph at the bottom of the screen will show your general condition See General Information About Body Fat for Recommended Body Fat Levels Body Fat Measuring Operation Using Memory optional This product features 10 personal memory settings allowing users to store height age and gender for frequent use To...

Page 4: ...t determine this as a reference point before measuring progress in a health program You must wait several hours before taking a body fat reading when drinking coffee or alcohol taking diuretic medications or exercising These all affect your level of hydration and the accuracy of this analyzer Precautions 1 OVERLOAD WARNING remove the weight immediately when the scale displays Err2 otherwise perman...

Page 5: ...66 3342 Manual de Instrucciones Balanza y analizador de la grasa corporal Cómo funciona el analizador de la grasa corporal y balanza Este instrumento utiliza BIA Análisis Bioeléctrico de Impedancia BIA es uno de los métodos más precisos de medir la grasa corporal Simplemente envía una señal inofensiva a través de la grasa y la masa muscular de su cuerpo Este método calcula tanto su peso personal c...

Page 6: ...as medias y los zapatos Tiene aproximadamente 5 segundos para pararse sobre la balanza en el Paso 5 antes de que ésta se apague automáticamente para conservar la batería 1 Antes de pararse sobre la balanza Presione el botón de encendido ON para ingresar al modo BFA Analizador de grasa corporal El número de la configuración anterior indicando la altura se mostrará en la pantalla El número correspon...

Page 7: ...Sports 8 Si el producto no se utiliza luego de ingresar al modo BFA analizador de grasa corporal se apagará automáticamente a los 10 segundos 9 La Gráfica de Exhibición de la Grasa Corporal en la parte inferior de la pantalla exhibirá su condición general Vea Información general acerca de la grasa corporal para los Niveles recomendados de grasa corporal Operación de medición de la grasa corporal u...

Page 8: ... ligeramente húmedos antes de pararse sobre la balanza 2 Mensaje en pantalla de Err0 Error de inicialización Se aconseja al usuario tomar nuevamente la medida para un resultado preciso 3 Mensaje en pantalla Err1 Uso incorrecto o cuerpo inestable Tome la medida nuevamente 4 Mensaje en pantalla Err2 Advertencia de sobrecarga Retire el peso de inmediato de lo contrario se ocasionará un daño permanent...

Reviews: