NATURAL GAS CONVERSION
Natural gas conversion must be performed only by natural gas provider or a service company.
1. Disconnect the propane hose from the gas valve (see Figure 12).
Caution:
The propane tank shall be shut off prior to disconnecting the propane hose, before proceeding with the
conversion.
2. Unscrew and disconnect the propane orifice from the bellows (see Figure 13). Propane orifice (2.21 mm diameter
size) is painted with red mark.
3. Replace the propane orifice withs the natural gas orifice and screw the natural gas orifice to the bellows tightly.
Then connect and tighten the natural gas orifice to the inlet tube (see Figure 14). The Natural gas orifice
(4.18 mm diameter size ) is painted with a black mark.
propane orifice
bellows
propane orifice
bellows
inlet tube
bellows
natural gas orifice
gas valve
propane hose