PREINSTALLATION  CHECKLIST  -  ALL  INSTALLATIONS

 

1.  Check to be sure your power source is capable of handling the 

voltage requirements of the motor, as indicated on the pump 

name plate.

2.  These pumps are not designed or intended to be used to handle 

sewage or effluent.

3.  This pump has been evaluated for use with WATER only.
4.  Maximum continuous operating water temperature for standard 

model pumps must not exceed 104°F (40°C).

Note: Pumps with the "CSA" mark are tested to CSA Standard 

C22.2 No. 108.

REFER TO WARRANTY ON PAGE 2.

PERFORMANCE

Your pump is designed to effectively pump clear all storm and drain 

waters. Although it will usually pass small particles suspended in 

water, grass, heavy mud, sand or pea gravel can clog the pump 

and reduce pump performance. This can usually be cleaned out by 

backflushing with a garden hose through the discharge. The normal 

performance that can be expected is as follows:

HP

GALLONS PER MINUTE AT 

DISCHARGE HEIGHT ABOVE 

PUMPING LEVEL

SHUT-OFF 

HEAD

5 Ft.

10 Ft.

15 Ft.

1/6

15

11

6

19 Ft.

1/4

30

22

12

20  Ft.

FW0697

0611

Supersedes

0810

DO NOT uSE FOR PuMPING OILS, GASOLINE OR ANY PETROLEuM bY-PRODuCTS.

Notice to Installer:  Instructions must remain with installation.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or

inconsistencies.

1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer  before 

using. Do Not remove the test plug in the cover.

2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials 

should be retained for future reference.

1.  Make sure there is a properly installed ground fault circuit 

interrupter (GFCI) protected circuit available.  All pumps are 

furnished with provisions for proper grounding to help protect you 

against the possibility of electrical shock.

2.  Make certain that the ground fault receptacle is within the reach 

of the pump’s power supply cord DO NOT USE AN EXTENSION 

CORD.  Extension cords that are too long or too light do not deliver 

sufficient voltage to the pump motor.  But, more important, they 

could present a safety hazard if the insulation were to become 

damaged or the connection ends were to fall into the sump and 

become wet.

3.  Make sure the pump electrical supply circuit is equipped with fuses 

or circuit breakers of proper capacity.  A separate branch circuit is 

recommended, sized according the National Electrical Code for the 

current shown on the pump name plate.

4.  TESTING FOR GROUND. As a safety measure, each electrical 

outlet should be checked for ground using an Underwriters 

Laboratory Listed circuit analyzer which will indicate if the power, 

neutral and ground wires are correctly connected to your outlet. If 

they are not, call a qualified licensed electrician.          

5.  Installation and checking of electrical circuits and hardware should 

only be performed by a qualified licensed electrician.

6.  FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP 

FROM ITS POWER SOURCE BEFORE HANDLING.

7.  These pumps are supplied with a 3-prong grounded plug to help 

protect you against the possibility of electrical shock.  DO NOT 

UNDER ANY CIRCUMSTANCES REMOVE THE GROUND 

PIN.  The 3-prong plug must be inserted in a mating 3-prong 

fault interrupter receptacle.  If the installation does not have such 

a receptacle, it must be changed to the proper type, wired, and 

grounded in accordance with the National Electrical Code and all 

applicable local codes and ordinances.

8.  Risk of electric shock. This pump has not been investigated for use 

in swimming pool areas.

9.  According to the state of California (Prop 65), this product contains 

chemicals known to the state of California to cause cancer and 

birth defects or other reproductive harm.

SEE bELOW FOR LIST OF CAuTIONS

SEE bELOW FOR LIST OF WARNINGS

INSTALLATION INSTRUCTIONS

MAIL TO:  95 North Oak Street • Kendallville, IN 46755

(260) 347-1600 • 1 (800) 345-9422 • FAX (260) 347-0909 

Quality Products Since 1866!

1/6 HP

115V @ 1.5 Amps

UTHAL

433039

UTFAL

1/4 HP

115V @ 2.5 Amps

2STHAL

473685

2STFAL

115V @1.5 Amps

UTFAL20

115V @2.5 Amps

2STFAL20

MODELS:

138011

Summary of Contents for 1/6 HP

Page 1: ...e is within the reach of the pump s power supply cord DO NOT USE AN EXTENSION CORD Extension cords that are too long or too light do not deliver sufficient voltage to the pump motor But more important they could present a safety hazard if the insulation were to become damaged or the connection ends were to fall into the sump and become wet 3 Make sure the pump electrical supply circuit is equipped...

Page 2: ... 020328 Adapter 020348 022467 Coupling N A 020331 Base 021338 020329 Screen 139492 139492 Mechanical Float Switch KH30 Optional This product is warranted for one year from the date of purchase or two years from the date of manufacture whichever occurs first Subject to the conditions hereinafter set forth the manufacturer will repair or replace to the original consumer any portion of the product wh...

Page 3: ...2 Cerciórese de que el receptáculo de corriente de fuga a tierra se encuentre dentro del radio de alcance del cable de alimentación de la bomba NO USE CABLE DE EXTENSIÓN Los cables de extensión demasiado largos o delgados no entregan suficiente voltaje al motor de la bomba Pero más importante aún es el peligro que se corre si el material aislante se daña o si los extremos de conexión caen dentro d...

Page 4: ...retire el filtro y limpie el área 5 Si es necesario retire los ocho 8 tornillos que unen la base de la caja espiral al motor y limpie la caja espiral PIEZAS DE RECAMBIO Lista de piezas de recambio Descripción Número de pieza Modelo de 1 6 HP Modelo de 1 4 HP Rotor 120334 020328 Adaptador 020348 022467 Acoplador N A 020331 Base 021338 020329 Filtro 139492 139492 Interruptor de flotador mecánico KH3...

Page 5: ...propriée afin de vous protéger contre les décharges électriques 2 Assurez vous que le réceptacle avec disjoncteur de fuite se trouve à proximité et peut accepter le cordon d alimentation de la pompe SANS RALLONGE La plupart des rallonges sont trop longues et de calibre trop faible pour assurer une tension suffisante à la pompe Mais ce qui est plus important encore elles présentent un risque si leu...

Page 6: ...base de la volute au boîtier du moteur et nettoyez la volute PIÈCES DE RECHANGE Liste des pièces de rechange Descripción Numéro de pièce Modèle 1 6 HP Modèle 1 4 HP Turbine 120334 020328 Adaptateur 020348 022467 Raccord N A 020331 Base 021338 020329 Tamis 139492 139492 Interrupteur pour flotteur mécanique KH30 Optionnel Ce produit est garanti pendant la période expirant la première un an après la ...

Reviews: