Home Decorators Collection 1007 459 006 Use And Care Manual Download Page 11

WARNING:

 

Perform all leak tests outdoors. 
Extinguish all open flames. 
NEVER leak test when smoking. 
Do not use the fire pit until all connections 
have been leak tested and confirmed no leakage.

 

Push in and turn control knob clockwise to OFF position.

Turn LP cylinder gas valve clockwise to OFF position when appliance is not in use.

HOMEDEPOT.COM/HOMEDECORATORS

Please contact 1-800-986-3460 for further assistance.

SHUTDOWN

Operation (continued)

CAUTION: 

The gas supply must be turned off at the LP gas supply cylinder when this appliance is not in use.

Leak Check

Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three parts water).
Apply several drops of solution where hose attaches to regulator.
Apply several drops of solution where regulator connects to cylinder.

 

Make sure all fire pit and light valves are OFF.
Turn cylinder valve ON.

If bubbles appear at any connection, there is a leak.

Turn cylinder valve OFF.

Regulator / Cylinder

     connection

Hose / Regulator

connection

11

 





If leak is at hose/regulator connection: tighten connection and perform another leak test. If bubbles
continue appearing, the hose should be returned to the place of purchase.
If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform another leak
check. If you continue to see bubbles after several attempts, cylinder valve is defective and should be
returned to cylinder’s place of purchase.
If NO bubbles appear at any connection, the connections are secure.

□□

Immediately remove any spot or stain.

To clean, wash with a mild soap, rinse with water and let air dry.
Do not use strong solvents or bleach as they may damage the surface.

Use an outdoor cover to extend the life of the item.

Care and Maintenance

CAUTION: 

Surfaces of fire pit can remain extremely hot for a period after use. 

Allow 45 minutes to cool down before touching or moving the fire pit.

 

NOTE: Whenever gas connections are loosened or removed, you must perform a complete leak test and 
complete the installation before use.

Summary of Contents for 1007 459 006

Page 1: ...e placed in Home Decorators Collection through the purchase of this fire pit We strive to improvement needs Thank you for choosing Home Decorators Collection Questions problems missing parts Before returning to the store call Home Decorators Collection Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 800 986 3460 HOMEDEPOT COM HOMEDECORATORS Item 1007 459 006 1007 497 702 1...

Page 2: ...r use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING If the information in this manual is not followed exactly a fire or explosion may result in causing property damage personal injury or loss of life WARNING For Outdoor Use Only Installation ...

Page 3: ...iance Any screen or guard removed for servicing the appliance must be replaced prior to operating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required as necessary It is imperative that the control compartments burners and circulat...

Page 4: ...pliance must have a capacity of 20 lb and must be equipped with a Type 1 connector and an OPD overfill protection device See Figure 1 The LP gas supply cylinder to be used must be constructed and marked in accordance with the specification for LP gas cylinders of the U S Department of Transportation DOT or the National Standard of Canada CAN CSA B339 Cylinder Sphere and Tubes for the Transportation ...

Page 5: ...mation go to www p65warnings ca gov WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury This warranty is for the original purchaser and applies to defects in materials and workmanship of your patio furniture provided your unit is maintained with care and used o...

Page 6: ... key 1 AA DD EE BB CC NOTE Hardware not shown to actual size 6 Pre assembly continued PACKAGE CONTENTS Part Description Quantity Part Description Quantity A Front panel 1 B Left panel 1 C Right panel 1 E Connecting rod 1 F Tabletop 1 G H Bracket Lava rocks 1 I Lid 1 D Back panel 1 A B C D E G H I F ...

Page 7: ... side plates with the connecting rod E 7 Assembly HOMEDEPOT COM HOMEDECORATORS Please contact 1 800 986 3460 for further assistance BB AA BB BB AA AA C A D E Attach the front panel A to the Left panel B with bolts AA and gaskets BB Don t tighten fully at this step BB AA B A 1 Installing the front and the left panels 2 Installing the right panel 3 Installing the back panel and the connecting rod C ...

Page 8: ...ce the tabletop F face down on a non abrasive surface Place the four panels of the frame A B C and D on top of the upside down tabletop Align the peg which is mid way down the rod at the top of the back panel D with the hole underneath the tabletop F as shown in the circle Align the holes of the four frame posts with the holes on the four corners of the tabletop F Use bolts CC and gaskets DD to at...

Page 9: ... the LP gas cylinder Hand tighten clockwise only To disconnect the gas hose from LP gas cylinder loosen the connector by turning counterclockwise by hand Install the LP gas cylinder not included to the fixing ring inside the fire pit and fasten with the adjusting screw Open the battery cap on the control panel and install one AAA battery not included Assembly continued 9 D Gently open the back panel...

Page 10: ...r flame lights If fire pit doesn t ignite within a few seconds push and turnthe control knob clockwise to OFF Fan with newspaper or magazine to ensure there is no propane gas in the fire bowl and inside of fire pit Wait 5 minutes repeat the lighting steps as outlined above Adjust flame to desired level with the control knob Lighting operations should comply with Lighting Instruction section Improper li...

Page 11: ...re is a leak Turn cylinder valve OFF Regulator Cylinder connection Hose Regulator connection 11 If leak is at hose regulator connection tighten connection and perform another leak test If bubbles continue appearing the hose should be returned to the place of purchase If leak is at regulator cylinder valve connection disconnect reconnect and perform another leak check If you continue to see bubbles...

Page 12: ...ssing parts Before returning to the store call Home Decorators Collection Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 800 986 3460 HOMEDEPOT COM HOMEDECORATORS Retain this manual for future use ...

Reviews: