Home Automation Omnistat RC-100B Owner'S Manual Download Page 12

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

13- 

HOLD

 

 

HOLD

 is displayed when the system is in Hold mode.

 

 

FILTER REMINDER

 

 
Your thermostat logs the amount of time your heating and cooling 
system has been running and gives you a reminder when it's time to 
replace your filter.

   

 

" F I L

 

t

 

will be displayed every four seconds in the place of the 

time display when it is time to change you filter.  To clear the 
reminder, press the Prog key.  The display will return to normal in 10 
seconds.  Don't forget to change your filter! 

 

ANTICIPATION 

 
Your thermostat has a sophisticated control system designed to keep 
you comfortable while saving energy.  Part of the control system is a 
feature called "anticipation", which anticipates the need to turn the 
system on or off before the temperature is actually at the setting. 
 
As humans, we perceive temperature as a combination of heat in the 
air and heat radiated from the walls and surroundings.  The thermostat 
also measures a combination of air and wall temperature.  When 
heating, the air temperature rises faster than the wall temperature.  The 
thermostat will turn the heat off briefly to prevent overheating the air 
while the wall temperature catches up.  Your comfort is assured 
without overshooting the heat setting, which wastes energy. 
 
In summer, the thermostat will periodically run the cooling system to 
circulate the air and remove humidity when the temperature is close, 
but not above the cool setting.  You will be more comfortable at a 
higher cool setting, which saves energy. 
 
Remember to allow some time for the thermostat to adapt to a new 
setting. 
 

Summary of Contents for Omnistat RC-100B

Page 1: ...O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Owner s Manual RC 100B RC 100BZ Heat Pump 2 Stage Heat 1 Stage Cool Document Number 13R00 3 May 2007 AUTO DAY COOL P ...

Page 2: ...d found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules This product generates and can radiate radio frequency energy Due to its low power design it is unlikely to interfere with radio and TV communications If it is suspected of doing so the user is encouraged to try to correct the problem by reorienting the receiver s antenna moving the receiver away fr...

Page 3: ... PUMPS 2 ENERGY EFFICIENT CONTROL 3 OPERATION 4 DISPLAY 7 FILTER REMINDER 9 ANTICIPATION 9 SETTING THE CURRENT TIME AND DAY 10 PROGRAMMING 10 SETTING TIME SCHEDULES 12 DAY NIGHT MODE 13 PROGRAMMABLE ENERGY SAVER MODE PESM 13 SYSTEM MODE 14 AUTOMATIC TIME UPDATE 14 ...

Page 4: ...of being controlled both locally and by remote control It offers programmability stand alone operation and robust communications with automation systems utility control systems and personal computers There are several items that can be configured at the time of installation These items have a check box for your installer to indicate which features are used in your system As an EPA ENERGY STAR Part...

Page 5: ...ectric heating While some heat pumps use outside air as their source of heat others use the heat available under the ground or in a water well These are called air source ground source or water source heat pumps respectively The RC 100 is capable of controlling all of these types of heat pumps In extremely cold conditions the heat pump may require assistance from another source of heat known as au...

Page 6: ... heat pumps should not be set back for periods of time less than 4 to 6 hours The RC 100 has microprocessor intelligence that continually monitors the performance of the heat pump and uses the auxiliary heat only when necessary If the RC 100 determines that the heat pump is able to heat at a rate of 5 degrees per hour or better the auxiliary heat will not be used If the heat pump is unable to heat...

Page 7: ...at will guide you through normal operation of your thermostat 2 Hold Press the Hold key to set the system into Hold mode In Hold mode the thermostat will not change its settings by program When hold mode is first turned on the RC 100 will use the auxiliary heat to get to the heat setting as quickly as possible Once the temperature is at or very near the heat setting or if the temperature is alread...

Page 8: ... the cooling system responds to maintain your desired cooling setting In Auto mode your thermostat will automatically switch between heat and cool to maintain your desired heating and cooling settings In Emergency Heat mode displayed as EM HEAT the thermostat will turn off the heat pump and use the auxiliary heating to maintain the temperature setting This mode should only be used if the heat pump...

Page 9: ... 8 Aux Heat Indicator The AUX HEAT indicator green glows when the auxiliary heat is on 9 Check Indicator The CHECK indicator red may be used to indicate a malfunction of the heat pump or for some other condition Your installer will explain its use Note To check your desired setting without changing it press the up or down arrow key or once ...

Page 10: ...ngs 2 Time Display Shows the current time of day 3 DESIRED DESIRED is displayed when the temperature display shows the desired temperature setting 4 OUTSIDE OUTSIDE will be displayed when the temperature display shows the outdoor temperature The outdoor temperature will be displayed every 4 seconds FAN AUTO MORN DAY EVE NITE REMOTE HOLD EM HEAT OFF COOL OUTSIDE DESIRED A ...

Page 11: ...T is displayed when the system is in Heat mode EM HEAT is displayed when the Emergency Heat is on 9 FAN FAN is displayed when the fan is set to run continuously 10 OFF OFF is displayed when the system is in the Off mode 11 REMOTE REMOTE is displayed when the last command received by the thermostat was sent by a remote system 12 Period Indicators MORN DAY EVE or NITE is displayed when scheduled tem...

Page 12: ... the need to turn the system on or off before the temperature is actually at the setting As humans we perceive temperature as a combination of heat in the air and heat radiated from the walls and surroundings The thermostat also measures a combination of air and wall temperature When heating the air temperature rises faster than the wall temperature The thermostat will turn the heat off briefly to...

Page 13: ...nk 1 Use the arrow keys to change the hour 2 Press the Prog key to advance to minutes 3 Use the arrow keys to change minutes 4 Press the Prog key to advance to day of week 5 Use the arrow keys to set the day of week 1 Monday 7 Sunday Press the Mode key when complete or simply wait 8 seconds for the display to return to normal ...

Page 14: ...lly exit programming mode after 20 seconds of no key activity When programming a time for the Morning Day Evening or Night period the time will be increased or decreased in 15 minute increments If the up arrow is pressed at 11 45 PM or the down arrow is pressed at 12 00 AM the time display will be blank indicating that no scheduled temperature changes will be made for that period Your thermostat w...

Page 15: ...sh 1 Use the arrow keys to change the scheduled time for the displayed period MORN DAY EVE or NITE 2 Press the Prog key to advance to the next item 3 Use the arrow keys to change the desired cool setting 4 Press the Prog key to advance to the next item 5 Use the arrow keys to change the desired heat setting 6 Press the Prog key to advance to the next period ...

Page 16: ...and is sent from a remote location You can use the arrow keys to override the temperature settings or press the Hold key to prevent any future remote changes Follow the procedure shown in Programming Mode to change the programmed DAY and NITE settings PROGRAMMABLE ENERGY SAVER MODE PESM Your thermostat can be configured to allow a remote system to override it The thermostat sends the temperature t...

Page 17: ...ture settings are changed at the thermostat REMOTE will no longer be displayed Press the Hold key to prevent thermostat programs or the remote system from changing temperature settings HOLD will be displayed at the thermostat AUTOMATIC TIME UPDATE The thermostat time will automatically be updated by the connected automation system POWER OUTAGES The thermostat will restart the heating cooling syste...

Page 18: ...sed to plan changes to the current schedule WEEKDAYS SATURDAYS SUNDAYS MORN 6 00 AM 8 00 AM 8 00 AM COOL 78 78 78 HEAT 70 70 70 DAY 8 00 AM COOL 85 85 85 HEAT 62 62 62 EVE 6 00 PM COOL 78 78 78 HEAT 70 70 70 NITE 10 00 PM 11 00 PM 10 00 PM COOL 82 82 82 HEAT 62 62 62 WEEKDAYS SATURDAYS SUNDAYS MORN COOL HEAT DAY COOL HEAT EVE COOL HEAT NITE COOL HEAT ...

Page 19: ......

Page 20: ...in this warranty are the sole and exclusive remedies therefor In no event shall HAI be liable for incidental expenses or consequential loss or damages Any implied warranties including warranties of merchantability and fitness for particular use or purpose is limited to a period of two 2 years from purchase date This warranty gives you specific legal rights and you may have other legal rights which...

Reviews: