![Home Automation INC. Omni IIe Owner'S Manual Download Page 71](http://html1.mh-extra.com/html/home-automation/inc-omni-iie/inc-omni-iie_owners-manual_2149224071.webp)
Pro-Link also has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Link
searches through all 64 text messages for a matching message. If one is found, the
When Message Received
event button
corresponding to the matching message is activated.
Pro-Link determines that a message has been received when:
•
One or more characters have been received followed by 100 ms of silence
•
One or more characters followed by a carriage return character are received
•
One or more characters followed by a line feed character are received
It is not necessary to enter the terminating carriage return or line feed character as part of the message name.
Switch Press Event Buttons (CentraLite)
When a button is pressed on a CentraLite keypad, the "When Switch" program is activated.
Pressing the 9 (SWITCH) key allows you to select the "When Command" for a switch pressed activated event.
You are first prompted to enter the switch number:
SWITCH NUMBER:
1-127
↓
Enter the switch number followed by the ' # ' key.
Edit Program Command
Selecting 2 (CMD), from the
Edit Program
menu, allows the commanded action for the program to be specified. The following
menu is displayed:
1=CONTROL 2=SECURITY
3=BUTTON 4=ALL
↓
5=TEMP 6=ENERGY
8=MESSAGE
↑
After the command is specified, the display returns to the
Edit Program
menu:
Program Control Commands
Press the 1 (CONTROL) key to command lights and appliances. Specify the desired command - See
Control
.
Porch
Light
(Unit
Name)
0=OFF
1=ON
2=DIM
3=BRT
↓
Porch
Light
(Unit
Name)
4=LVL
5=RMP
9=TIM
#=STA
↑
If the selected unit is part of a House Code that is configured to use the Compose Format, the second page of the menu is
modified to allow Scene commands. Consequentially, the Level and Ramp Commands are removed from the menu.
Entry
Lights
(Unit
Name)
4=SCN 9=TIM #=STA
↑
Page 63