Insert the heat pipe assembly (the end of the exhaust joint) into the back panel vent slot

(push to the left) and complete the assembly (as shown in figure 1). 
1.2 Installation of window sealing plate components 
1

Half open the window

and mount the window sealing plate assembly to the window (as

shown in Fig.2 and Fig.3).Components can be placed in horizontal and vertical direction. 
2

Pull various components of the window sealing plate assembly open, adjust their opening 

distance to bring both ends of the assembly into contact with the window frame, and fix 
various components of the   
assembly.1.2 Install the window sealing plate assembly 
Notes: 
1

the flat end of the exhaust pipe joints must be snapped into place.

2)The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep the
ventilation of the exhaust pipe not blocked. 

      Figure 2 

Figure 3 

1.3 Install the body 
1

Move the machine with installed heat pipe and fittings before the window, and the

distance between the body and walls or other objects shall be least 50 cm (as shown in 
Fig.4)

.

 

Figure4 

2

Elongate the exhaust pipe and snap the flat end of the exhaust pipe joints into the hole of 

the window sealing plate assembly (as shown in Fig.5 and Fig.6) . 

Notes

 

Summary of Contents for 823-013V70

Page 1: ...ASSEMBLY INSTRUCTION INcjg002_UK 823 013V70 READ AND SAVE THIS INSTRUCTION FOR FUTURE USE ...

Page 2: ... 3 II Features and Components 5 6 III Control Setting 7 IV Protection function 8 9 V Installation and adjustment 9 11 VI Drainage Instructions 11 12 VII Maintenance 12 13 VIII Unit Storage 13 IX Troubleshooting 13 20 X Addendum 21 ...

Page 3: ...liance shall be installed operated and stored in a room with a floor area larger than 10 m2 6 Keep any required ventilation openings clear of obstruction 7 Servicing shall be performed only as recommended by the manufacturer 8 The appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation 9 Any person who is involved with working...

Page 4: ...e make sure that it is in an upright position The machine should stay away from gasoline flammable gas stoves and other heat sources Don t disassemble overhaul and modify the machine arbitrarily otherwise it will cause a machine malfunction or even bring harm to persons and properties To avoid danger if a machine failure occurs ask the manufacturer or professionals to repair it Do not install and ...

Page 5: ...nt Storage package protection should be constructed For example mechanical damage to the equipment inside the package won t cause a leak of the refrigerant charge The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations II Features and Components 1 Features New look compact structure streamlined machine aristocratic atmosphere With cooling d...

Page 6: ...6 2 Components Window Sealing Plate Assembly Exhaust Pipe Assembly ...

Page 7: ...ing mode 3 Fan Speed Selection Key In cooling mode press the key to select high or low wind speed operation In fan mode press the key to select high or low wind speed operation In dehumidifying mode pressing the key is invalid and the fan will forcibly choose low wind speed operation 4 Up Key and Down Key press the two keys to change the setting temperature or setting time operate as follows While...

Page 8: ...el is as follows Instructions of key operation of the high quality remote control are as follows 1 Power press the key to turn on or turn off the machine 2 Timer press the key to set timing 3 Down press the key to lower temperature and timing set value 4 Mode press the key to switch among cooling fan dehumidifying mode 5 Up press the key to turn up temperature and timing set value 6 Fan press the ...

Page 9: ...automatic defrosting function Defrosting can be achieved through four way valve reversing 3 4 Protection Function of the Compressor To increase the service life of the compressor it has a 3 minute delay booting protection function after the compressor is turned off V Installation and adjustment 1 Installation Warning before using the mobile air conditioning keep it upright for at least two hours T...

Page 10: ...ly into contact with the window frame and fix various components of the assembly 1 2 Install the window sealing plate assembly Notes 1 the flat end of the exhaust pipe joints must be snapped into place 2 The pipe cannot be distorted nor has substantial turning greater than 45 Keep the ventilation of the exhaust pipe not blocked Figure 2 Figure 3 1 3 Install the body 1 Move the machine with install...

Page 11: ...ses or this may cause a malfunction Exhaust host must be not blocked otherwise it may cause overheating VI Drainage Instructions This machine has two drainage methods manual drainage and continuous drainage 1 Manual drainage 1 When the machine stops after the water is full turn off the machine power and unplug the power plug Notes Please move the machine carefully so as not to spill the water in t...

Page 12: ...rainage cover 2 Continuous drainage Optional only applicable to dehumidifying mode as shown in figure 1 Unscrew the drainage cover and unplug the water plug 2 Set the drainage pipe into the water outlet 3 Connect the drainage pipe to the bucket VII Maintenance Cleaning before cleaning and maintenance turn off the machine and unplug the plug 1 Clean the surface Clean with surface of machine with a ...

Page 13: ...irectly tilt the body to discharge the water into other containers 2 Turn on the machine adjust it to low wind ventilation mode and maintain this state until the drainage pipe becomes dry so as to keep the inside of the body in a dry state and prevent it from mildewing 3 Turn off the machine unplug the power plug and wrap the power cord around the wrapping post install the water plug and the drain...

Page 14: ...rking adequately sealed or intrinsically safe 5 Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand Have a dry powder or CO2 fire extinguisher adjacent to the charging area 6 No ignition sources No person carrying out work in relation to a refrigeration system whi...

Page 15: ...nst being so corroded 9 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If the fault cannot be corrected immediately but it is necessary to continue opera...

Page 16: ...specified by the manufacturer Other parts may result in the ignition of refrigerant in the atmosphere from a leak 4 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans 5 Detection...

Page 17: ...ess may need to be repeated several times Compressed air or oxygen shall not be used for this task Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved then venting to atmosphere and finally pulling down to a vacuum This process shall be repeated until no refrigerant is within the system When the final OFN charge is ...

Page 18: ... a manifold so that refrigerant can be removed from various parts of the system f Make sure that cylinder is situated on the scales before recovery takes place g Start the recovery machine and operate in accordance with manufacturer s instructions h Do not overfill cylinders No more than 80 volume liquid charge i Do not exceed the maximum working pressure of the cylinder even temporarily j When th...

Page 19: ... be removed ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppliers Only electric heating to the compressor body shall be employed to accelerate this process When oil is drained from a system it shall be carried out safel...

Page 20: ...n 17 62 The cooling effect is not good There is direct sunlight Pull the Curtain Doors or windows are open there are a lot of people or in cooling mode there are other sources of heat Close doors and windows and add new air conditioning The filter screen is dirty Clean or replace the filter screen The air inlet or outlet is blocked Clear obstructions Big Noise The air conditioning is not placed on...

Page 21: ...nd related circuitry Note If problems not listed in the table occur or recommended solutions do not work please contact the professional service organization X Addendum Schematic diagram for air conditioning The specific technical parameters of the machine shall be subject to the nameplate on the product Treatment Don t put the abandoned machine with other unsorted waste together Such waste shall ...

Page 22: ......

Reviews: