HOMCOM 820-274 Operation Instruction Download Page 4

9.Do not remove button parts of the warmer.
10.This warmer is only suitable for use in the room.
11.After dust removal, the oil left on the surface should be removed.

IV.Warning

1. If the supply cord is damaged, it must be replaced by the manufacturer or its service 
agent or a similarly qualified person in order to avoid a hazard.
2. The heat must not be located immediately below a socket-outlet.
3. Don’t use this heater in the immediate surroundings of bath, a shower or a swimming 
pool.
4. This heater is filled with a precise quantity of special oil. Repairs requiring opening of 
the oil container are only to be made by the manufacturer or his service agent who should 
be contacted if there id an oil leakage.
5. Regulations concerning the disposal of oil when scrapping the appliance have to be 
followed. Please, don't throw away and be burnt on purpose.
6. WARNING: In order to avoid overheating do not cover the heater.
7. This appliance is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they 
have been given supervision or instruction concerning use of the appliance by a person 
responsible for their safety.
8. Children should be supervised to ensure that they do not play with the appliance.

Correct Disposal of this product

This marking indicates that this product should not be disposed with other household
wastes throughout the EU. To prevent possible harm to the environment or human
health from uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device, please use the
return and collection systems or contact the retailer where the product was purchased.
They can take this product for environmental safe recycling.

Type

Number

of

radiating

fins

Rated
voltage
(V)

Frequency
(Hz)

Rated
power
input (W)

Power in
Level

(W)230V

Power in
Level

(W)230V

Total input

power in

Level

(W)230V

HD984-R5Q

5

220-240

50/60

910-1100

400

600

1000

HD984-R7Q

7

220-240

50/60

1370-1630

600

900

1500

HD984-R9Q

9

220-240

50/60

1830-2180

800

1200

2000

HD984L-R11Q

11

220-240

50/60

2000-2400

1000

1200

2200

HD984B-R11Q

11

220-240

50/60

2290-2720

1000

1500

2500

HD984B-R13Q

13

220-240

50/60

2290-2720

1000

1500

2500

HD984B-R15Q

15

220-240

50/60

2560-3050

1200

1600

2800