Homa Barracuda GRP 111 Installation And Operation Instruction Manual Download Page 10

 

10

Contents

 

 

Contents Page 

  1.    EC Declaration of Conformity 

10 

  2.    Safety Warnings 

11 

  2.1. General instructions 

11 

  2.2. General Safety Precautions 

11 

  3.    Applications and Technical 
         Description 

11 

  3.1. Applications 

11 

  3.2. Technical Data 

11 

  3.3. Operation Conditions 

11 

  3.4. Explosive Enviroments 

11 

  4.    Warranty 

11 

  5.    Transport and Storage 

12 

  6.    Electrical Connection 

12 

  6.1. Connection of 1 Ph-Motors 

12 

  6.2. Connection of 3 Ph-Motors 

12 

  6.3. Temperature Sensors 

12 

  6.4. Oil-chamber Seal Condition Sensors 

12 

  6.5. Check of Direction of Rotation 

13 

  7.    Installation 

13 

  7.1. Submerged Base Stand Installation 

13 

  7.2. Submerged Installation with Auto- 
         Coupling 

13 

  7.3. Automatic Float Switch Control 

13 

  8.    Start-Up 

13 

  9.    Maintenance and Repair 

14 

10.    Fault Finding Chart 

14 

11.    Warranty Conditions and Warranty  
         Receipt 

15 

13.    Wiring diagrams 

22 

14.1. GRP 16 – GRP 50 

22 

14.2. GRP 56 – GRP 111 

22 

14.3. Starter Connection 

23 

14.    Dimensions 

24 

14.1. Submerged Base Stand 

24 

14.2. Submerged Installation with Auto- 
         Coupling 

25 

15.    Order Sheet for Spare Parts 

26 

16.    Spare Part List and Drawings 

28 

16.1. Spare Part List 

28 

16.2. Spare Part Drawings 

30-33 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1. Declaration of Conformity 

 

EC Declaration of conformity in line with the EC Ma-
chinery Directive 89/392/EEC, Appendix IIA 

 
We, HOMA Pumpenfabrik GmbH, Industriestrasse 1,  
D-53819 Neunkirchen-Seelscheid, hereby declare that in 
respect to their design and construction the following 
pump types, in the form in which they are marketed by us, 
conform to the relevant fundamental safety and health 
requirements of the EC Machine Directives: 
 

GRP 16 

GRP 22 

GRP 26 

GRP 36 

GRP 44 

GRP 50 

GRP 56 

GRP 76 

GRP 111 

 

EC-Directives to which the pumps conform: 

EC Machinery Directive 

98/  37/EEC 

EC Directive, electromagnetic 
compatibility 

89/336/EEC  

as amended 

92/  31/EEC  

as amended 

93/  68/EEC  

EC Low Voltage Directive 

1)

 

73/  23/EEC  

EC Directive, explosion-
prooved operating material 

2)

 

94/    9/EEC 

EC Directive, construction 
products 

89/106/EEC 

 
Relevant harmonized industrial standards: 

ES 60335-2-41

1)

 ES 

60335-1

1)

  ES 60034 Part 5 

ES 60204 Part 1

1)

  ES 61000-6-1  ES 61000-6-2 

ES 61000-6-3 

ES 61000-6-4  ES 55014-1 

ES 55014-2 

ES 61000-3-2  ES 61000-3-3 

ES 12050 1-4 

ES 292 

ES 50014/18/19/20

2)

 

 

Specially applied national standards and technical 
specifications (other applied standards for general 
mechanical engineering are deposited at the con-
struction office):

 

ISO 9906 

DIN 24250 

 
 
 
 
 
 

(Dr. Klaus Hoffmann, 

Management) 

01.10.2004 

HOMA Pumpenfabrik GmbH 

 
 

1)

 does not apply to Ex models 

2)

 only applies to Ex models 

 
 
 
 
 
 
 
 

Established:     Totzke  Index: 

            0 

Date: 

01.06.2004  Current number:     CE  1

 

Summary of Contents for Barracuda GRP 111

Page 1: ...Montage und Bedienungsanleitung Installation and Operation Instruction Manual Montage en Bedrijfsinstrukties 01 2005 Baureihe Series Serie Barracuda GRP...

Page 2: ...Pagina 24 Seite 28 Page 28 Pagina 29 DEUTSCH ENGLISH NEDERLANDS Elektroanschluss Electrical connection Elektrische aansluitingen Bauma e Dimensions Afmetingen Ersatzteilliste und Ersatzteilzeichnunge...

Page 3: ...OMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid erkl ren hiermit dass die Pumpentypen GRP 16 GRP 22 GRP 26 GRP 36 GRP 44 GRP 50 GRP 56 GRP 76 GRP 111 aufgrund Ihrer Konzipierun...

Page 4: ...ten aus dieser Bedienungsanleitung nicht eingehalten werden nicht haften F r Zubeh rteile gelten die gleichen Bestimmungen 3 Einsatz und Technische Beschreibung 3 1 Einsatz der Pumpen Beim Einsatz der...

Page 5: ...60 330 30 450 GRP 26 W Ex 100 320 50 450 6 2 Anschluss 3Ph Motoren Barracuda GRP Pumpen mit 3Ph Motoren m ssen an ein Schaltger t mit Motorschutzschalter angeschlossen werden Original HOMA Schaltger...

Page 6: ...ellung Den Bodenst tzring mit Schrauben am Saugstutzen der Pumpe befestigen 90 Anschlu winkel bzw bogen am Druckstutzen der Pumpe befestigen Druckleitung montieren Absperrschieber und R ckschlagklappe...

Page 7: ...den die durch unser Ger t verursacht werden und auf unsachgem en Reparaturversuchen beruhen welche nicht vom Herstellerwerk oder einer autorisierten Fachwerkstatt durchgef hrt wurden oder wenn bei ei...

Page 8: ...l uft aber der Motorschutzschalter l st nach kurzem Betrieb aus Motorschutzschalter zu niedrig eingestellt Einstellung nach den Daten auf dem Pumpentypenschild vornehmen Erh hte Stromaufnahme aufgrund...

Page 9: ...er Stra e 76 Akazienweg 16 01796 Pirna 68809 Neulussheim 0 35 01 52 34 48 0 62 05 3 11 12 PAW Pumpen Aggregate GbR Giese Pumpentechnik Kleine Basch tzer Str 3 Belsemer Steg 14 02625 Bautzen 72131 Ofte...

Page 10: ...line with the EC Ma chinery Directive 89 392 EEC Appendix IIA We HOMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid hereby declare that in respect to their design and constructi...

Page 11: ...Description 3 1 Applications If the pump is used for cleaning or maintenance of swimming pools make sure that no persons stay in the swimming pool during operation of the pump and that the pump is se...

Page 12: ...each of the stator windings is connected to one pump cable wire The wires are marked U1 U2 V1 V2 W1 W2 For star delta start the pump must be connected to an appropriate starter box see fig 2 and 3 If...

Page 13: ...ed procedures and without exposing the pipe to distortion or tension Insert the guide rails in the ring of the auto coupling base and adjust the length of the rails by cutting them accurately to the g...

Page 14: ...il becomes greyish white like milk if it contains water This may be the result of defective shaft seal In this case leave the condition of the shaft seals by a HOMA Service to examine The oil should b...

Page 15: ...defeated by a streng tech nical end control before delivery If the unit still gives an occasion for a legitimated complain you have the claim of an appropriated correction free of charge Warranty rep...

Page 16: ...lage II A Wij HOMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid verklaren hiermee dat de pomp typen GRP 16 GRP 22 GRP 26 GRP 36 GRP 44 GRP 50 GRP 56 GRP 76 GRP 111 Op grond van...

Page 17: ...p dat wij volgens de product aansprakelijkheidswet niet aansprakelijk zijn voor schade welke door onze machines veroorzaakt worden wanneer de aanwijzingen en voorschriften uit deze gebruiksaanwijzing...

Page 18: ...oeten aan een schakelkast met motorbeveiligingsschakelaar aangesloten worden Originele HOMA schakelkasten zijn als toebehoor leverbaar Bij toepassing van andere schakelkasten dient men voor de keuze v...

Page 19: ...g De pomp aan de handgreep met een touw of ketting in de vloeistof laten zakken Als de pomp in modder of op een ongelijke bodem wordt opgesteld is het raadzaam de pomp op bakstenen te plaatsen 7 2 Nat...

Page 20: ...INELE ONDERDELEN verwerkt zijn Voor appendages gelden dezelfde regels Voor elke arbeid de pomp van de elektro aansluiting loskoppelen om inschakeling van de pomp tijdens de werkzaamheden uit te sluite...

Page 21: ...n uitbouwkosten van de voor garantie in aanmerking komende machine op de bedrijfslocatie reiskosten van het reparatiepersoneel van en naar de bedrijfslocatie als mede transportkosten zijn geen bestand...

Page 22: ...Temperature sensors approx 140 C Teperatuurvoelers ca 140 C S1 S2 Dichtungs berwachung lkammer Oil chamber seal condition sensor Dichtingscontrole Oliekamer Abb 2 Fig 2 Anschlussdiagramm Standardmotor...

Page 23: ...bereitete Motoren Alle Wicklungsenden ber Anschlusskabel zug nglich Dreieckschaltung der Wicklung Starter Connection Direct on Line DOL Start for Star Delta prepared Motors Delta Connection of Sta tor...

Page 24: ...26 Ex 618 165 350 191 R 2 AG BSP 2 M 150 350 36 HD Ex 655 165 350 191 R 2 AG BSP 2 M 150 350 44 Ex 695 180 350 199 R 2 AG BSP 2 M 150 350 25 50 Ex 695 180 350 199 R 2 AG BSP 2 M 150 350 25 GRP 56 Ex...

Page 25: ...ISO Pipe 2 ISO 292 Rohr 1 ISO Pipe 1 ISO 87 563 625 1000 297 76 Ex 790 182 728 300 170 Rohr 2 ISO Pipe 2 ISO 292 Rohr 1 ISO Pipe 1 ISO 87 563 625 1000 297 111 Ex 862 182 728 300 170 Rohr 2 ISO Pipe 2...

Page 26: ...Nr Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 15 Order Sheet for Spare Parts To HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47 7 02 44 Pump type see pump label Ye...

Page 27: ...efoon 0183 622212 Fax 0183 620193 Pompentype Typeplaatje Bouwjaar Typeplaatje Gedetailleerde onderdelenlijst 1 Pos Nr Beschrijving Aantal 2 Pos Nr Beschrijving Aantal 3 Pos Nr Beschrijving Aantal 4 Po...

Page 28: ...g 999 xx Ersatzteile f r Schaltger t 722 Anschlu stutzen 16 Spare part list and drawings 16 1 Spare part list ATTENTION The following list contains parts that do not correspond to every pump type For...

Page 29: ...bord 410 Dichtingklep voor RFV 836xx Klemmenbord 411xx Dichtingsring bijv 411 01 02 voor olie plug 411 03 837 Bedrijfscondensator 412xx O ring 838 Schakelkast 420 Keerring 838 09 Startrelais 420 01 Ke...

Page 30: ...30 16 2 Ersatzteilzeichnung Spare part drawings Onderdelentekening GRP 16 GRP 16 Ex GRP 16 B GRP 16 B Ex...

Page 31: ...31 GRP 22 GRP 26 GRP 22 Ex GRP 26 Ex GRP 36 GRP 36 Ex...

Page 32: ...32 GRP 44 GRP 50 GRP 44 Ex GRP 50 Ex...

Page 33: ...33 GRP 56 GRP 76 GRP 111 GRP 56 Ex GRP 76 Ex GRP 111 Ex GRP 56 U GRP 76 U GRP 111 U GRP 56 U Ex GRP 76 U Ex GRP 111 U Ex...

Page 34: ...Notizen Notes...

Page 35: ...35...

Page 36: ...36...

Reviews: