5. Setup and Commissioning

5.1. General

To prevent damage to the pump when setting up and in 
operation, the following points are to be followed:

• 

The setup work is to be carried out by qualified staff, 
following the safety provisions.

• 

Before setting up, the pump is to be investigated for 
any damage.

• 

Where there are level control systems, ensure mini-
mum water coverage.

• 

Air pockets in the pump housing and pipework must 
be avoided (by suitable ventilation equipment or by 
slightly slanting the pump).

• 

Protect the pump from frost.

• 

The electricity lines of the pump must be laid in such 
a way that it operates without any risk and it is simple 
to install/remove.

• 

Carry the pump by the handle and drain with a cable 
or a chain into the conveying medium, not by the ca-
ble.

• 

When the ground is muddy prevent stones or similar 
from being located underneath the pump, to prevent 
sinking in.

• 

When using a hose, ensure that it can be laid without 
kinking.

5.2. Installation

Danger from falling!

When installing the pump and its accessories, work 

is done directly on the edge of the basin. If you do 

not pay attention or wear improper footwear, this can 

lead to falls. There is danger of death! Take all the 

safety measures to prevent this.

Fasten the pressure line or the hose onto the pressure 
connection of the pump and lay the pressure line. When 
using a hose or pipe connection with thread, the hose 
sleeve on the pump connector can be trimmed. To guar-
antee optimum conveying power, the pressure line must 
have a diameter of at least ¾“. To prevent reflux of the 
water when the pump is shut down, a nonreturn valve 
must also be fitted in the pressure line. The pressure line 
must be fitted tension-free.

When using a hose, ensure that this is laid without kinks. 
When using accessories, such as a rapid coupling or simi-
lar, for example, ensure that this is sealed with Teflon tape 
to ensure there are no leaks in the conveying power of 
the pump.

Attach a rope or chain to the handle of the pump and use 
this to lower it into the conveying medium. The pump 
must be set down securely on the floor, open any shut-off 
valves.

As the pump may operate with very low pumping heights, 
the pump must be placed on a firm, non-flexible floor. If 
the pump is standing on the flexible floor (e.g. in the plas-
tic tank) the pump sucks firmly to the floor and cannot 
convey fluids.

The sensor switch must be placed onto the floor with the 
electrodes underneath. Ensure that the lower edge of the 
sensor switch housing has direct contact with the floor, 
to ensure it is working perfectly. The overrun time of the 
pump is 4 minutes.

Pumping Height

The pump is equipped with adjustable rubber feet:

• 

1 mm residual water pumping height without sup-
porting feet. To do this, remove the 3 rubber feet 
from the underside of the pump.

• 

2mm residual water pumping height with supporting 
feet. (Condition as supplied).

• 

10 mm residual water pumping height. To do this, re-
move the 3 rubber feet in their opening on the under-
side of the pump, turn 180° and reinsert.

The pumping heights below 3mm are special pumping 
heights and restrict the flow on the suction side due to 
the decreased cross-section. The conveying power of the 
pump is restricted by this effect. The pump achieves full 
power with a pumping height of 3mm.

Installation of a Nonreturn Valve

In most applications, the pumps are used as an emergen-
cy pump and are therefore only rarely put into operation. 
This is why the pump is not equipped with a nonreturn 
valve as standard. The reason for this is that is may effect 
the functioning of the pump under certain conditions. If 
there has been a very long time (months or years) since 
it was last put into operation, then there may be dirt from 
the stagnant water column on the nonreturn valve (which 
was sufficiently contained in the surface water pumped 
when it was last operated) that has deposited on the non-
return valve and prevents it from opening. This particularly 
applies as the pump must be completely ventilated each 
time it is started for the first time after it has been stand-
ing for a long time.

The disadvantage for an installation without nonreturn 
valve, that the water returning from the pipe must be ac-
cumulated with the remaining residual water (mopped up 
or removed by wet vaccuum cleaner) is therefore overrid-
den by a possible failure of the pump in an emergency. 
Because of this, a nonreturn valve must only be fitted for 
applications with frequent operation (at least 1 x week).

Automatic Moisture Sensor Switch for Model C240 WF

The pump is equipped with a moisture sensor switch 
that turns on the pump when the water level is just 4.5 
mm. The pump remains in operation until a residual water 
height of 2mm is reached. The sensor switch is connect-
ed to the pump by a cable.

Mobile Operation

If a hose is used as a pressure line, ensure that this is 
completely emptied before immersing the pump for each 
pumping process. Remaining liquid would still prevent 
ventilation of the pump housing and therefore prevent 
conveying the liquid. For the same reason, before im-
mersing, also do not convey with a pump that is already 
switched on.

Summary of Contents for 9110371

Page 1: ...Version 07 2017 No 00509006 02 Original Betriebsanleitung EN Original Instruction Manual FR Manuel d instructions original NL Originele handleiding C240W F...

Page 2: ...2 9 Schalldruck 08 3 Allgemeine Beschreibung 09 3 1 Verwendung 09 3 2 Einsatzarten 09 3 3 Aufbau 09 4 Verpackung Transport und Lagerung 11 4 1 Anlieferung 11 4 2 Transport 11 4 3 Lagerung 11 4 4 R ckl...

Page 3: ...bsanleitung verbleibt bei der HOMA Pumpenfabrik GmbH Diese Betriebsanlei tung ist f r das Bedienungs Montage und Wartungsper sonal bestimmt Sie enth lt Vorschriften und Zeichnungen technischer Art die...

Page 4: ...on Personen f hren 1 5 3 Wartung Die vorgeschriebenen Wartungs und Inspektionsarbeiten sind regelm ig durchzuf hren und d rfen nur von qualifi zierten und autorisierten Personen durchgef hrt werden Wa...

Page 5: ...romaschinen und Pumpentechnik GmbH Tankweg 27 44147 Dortmund 02 31 98 20 22 0 B hler Antriebstechnik Elektro Maschinen GmbH Wei erlenstr 1G 79108 Freibung Hochdorf 07 61 13 09 70 Glaubrecht Pumpenserv...

Page 6: ...etriebsmittel kann pausenlos unter Nennlast arbei ten ohne dass die zul ssige Temperatur berschritten wird Betriebsart S2 Kurzzeitbetrieb Die Betriebsdauer wird in Minuten angegeben z B S2 20min Das b...

Page 7: ...llstand gekom men sein Der Bediener hat jede auftretende St rung oder Unregelm igkeit sofort seinem Verantwortlichen zu melden Eine sofortige Stillsetzung durch den Bediener ist zwingend erforderlich...

Page 8: ...seinrichtungen ausgestattet Diese Einrich tungen d rfen nicht demontiert oder abgeschaltet wer den Einrichtungen m ssen vor der Inbetriebnahme vom Elektrofachmann angeschlossen und auf eine korrekte F...

Page 9: ...mpenf e ist eine Flachabsaugung auf bis 1mm m glich Schmirgelnde oder andere werkstoffangreifende Stof fe k nnen die Pumpe zerst ren Die Pumpe ist nicht geeignet f r den Einsatz in F rdermedien mit ab...

Page 10: ...i Mediumtemperatur bis 60 C S2 20min S3 40 Zul ssige Mediumtemperatur 60 C Schutzart IPX8 Standart Kabell nge 10 m Spannung 230V 1Ph 50Hz Warnung vor drehendem Laufrad Das drehenden Laufrad nicht anfa...

Page 11: ...htigkeit die F rderleistung der Pumpe vermindert Die Pumpe am Haltegriff mit Seil oder Kette befestigen und daran ins F rdermedium herunterlassen Die Pumpe muss sicher auf dem Boden aufgestellt sein g...

Page 12: ...C240 WF Die Pumpe ist mit einem Feuchtigkeits Sensorschalter ausgestattet der die Pumpe bereits ab einem Wasser stand von 4 5 mm einschaltet Die Pumpe bleibt solange in Betrieb bis eine Restwasserh he...

Page 13: ...nde Punkte sind zu beachten Die Betriebsanleitung muss dem Wartungspersonal vorliegen und beachtet werden Es d rfen nur War tungsarbeiten und ma nahmen durchgef hrt wer den die hier aufgef hrt sind S...

Page 14: ...Bei l ngeren Stillstandszeiten sollte in regelm igen Abst nden monatlich bis viertelj hrlich ein 5 min tiger Funktionslauf durchgef hrt werden Vorsicht Ein Funktionslauf darf nur unter den g ltigen B...

Page 15: ...pr fen und ggf erneuern lassen Ausl sen von Sicherungen Motorschutzschalter und oder ber wachungseinrichtungen Anschl sse vom Fachmann pr fen und ggf ndern lassen Motorschutzschal ter und Sicherungen...

Page 16: ...t unruhig und ger uschvoll Ursache Abhilfe Maschine l uft im unzul ssigen Betriebsbereich Betriebsdaten der Maschine pr fen und ggf korrigieren und oder Betriebsver h ltnisse anpassen Saugstutzen sieb...

Page 17: ...DEUTSCH 17 Notizen Notes...

Page 18: ...3 General Description 23 3 1 Usage 23 3 2 Usage Types 23 3 3 Structure 24 4 Package Transport Storage 25 4 1 Delivery 25 4 2 Transport 25 4 3 Storage 25 4 4 Returning to the supplier 25 5 Setup and C...

Page 19: ...ersonnel It contains technical specifications and diagrams which may not be reproduced or distributed either completely or in part or used for any other purpose without the expressed consent of the ma...

Page 20: ...ted in this operation and maintenance manual and all types of repair work may only be performed by the manufacturer and its authorized service centres 1 5 4 Damage to the product Damage as well as mal...

Page 21: ...on All instructions and information must be observed and followed during the various phases of the product s lifecycle installation operation maintenance transport etc The operator is responsible for...

Page 22: ...ult in fatal injury This work may only be carried out by a qualified electrician Beware of damp Moisture penetrating cables can damage them and render them useless Furthermore water can pen etrate int...

Page 23: ...absolutely prohibited to pump explosive liquids e g gasoline kerosene etc The products are not designed for these liquids 2 9 Sound Pressure Depending on the size and power kW the pump has a sound pr...

Page 24: ...6 Suction screen 7 Cable 8 Handle 9 Sensor 10 Rubber base 3 3 1 Rating Plate 23 50 Nr 1 Ph 1 Model Description 2 Serial Number 3 Frequency 4 Power P1 5 Rated current 6 Speed of Motor 7 Insulation cla...

Page 25: ...t Housing Sealing is provided by three axial shaft seals 4 Package Transport Storage 4 1 Delivery On arrival the delivered items must be inspected for dam age and a check made that all parts are prese...

Page 26: ...f the sensor switch housing has direct contact with the floor to ensure it is working perfectly The overrun time of the pump is 4 minutes Pumping Height The pump is equipped with adjustable rubber fee...

Page 27: ...tion is not necessary as it can always run with the correct direction of rotation 5 7 Type of Activation Types of Activation with Plug Plug the plug in the socket provided for this purpose Pump runs d...

Page 28: ...etc must be checked for correct fitting Loose or defective accessories must be repaired replaced immediately 7 Shutdown 7 1 Temporary shutdown For this type of shutdown the machine remains installed a...

Page 29: ...technical instruc tions and to correct if appropriate Impeller propeller slowed down due to adhesions obstructions and or solids increased power input Switch off machinery secure against restart rest...

Page 30: ...operation Specialist to check connection and to correct if appropriate Wear and tear Replace worn parts Engine mount defective Contact the manufacturer Machine mounted askew Check assembly and use ru...

Page 31: ...English 31 Notizen Notes...

Page 32: ...que 37 3 Description g n rale 37 3 1 Utilisation 37 3 2 Modes d utilisation 37 3 3 Construction 38 4 Emballage transport et stockage 39 4 1 Livraison 39 4 2 Transport 39 4 3 Stockage 39 4 4 Retour 39...

Page 33: ...ion des accidents La pr sente notice d utilisation doit tre en permanence la disposition du personnel op rateur sur le site d utilisation du produit 1 3 Utilisation conforme Les produits Homa r ponden...

Page 34: ...onnes qualifi es et autoris es Tous les travaux de maintenance et tous les types de travaux de r paration qui ne sont pas mentionn s dans la pr sente notice d utilisation ne peuvent tre ex cut s que p...

Page 35: ...tection de niveau 2 S curit Ce chapitre mentionne toutes les consignes de s curit et instructions techniques g n ralement applicables Lors du transport de l installation de l exploitation de la main...

Page 36: ...umidit L introduction d humidit dans le c ble endommage ra le c ble et le rendra inutilisable De plus de l eau peut s introduire dans le local de raccordement ou le moteur et causer des dommages aux b...

Page 37: ...gents explosifs Le pompage d agents explosifs p ex essence k ros ne etc est strictement interdit Les produits ne sont pas con us pour ces agents 2 9 Pression acoustique Selon sa taille et sa puissance...

Page 38: ...tion 8 Norme 9 Hmax hauteur de refoulement max 10 Qmax d bit de refoulement max 11 Temp rature de l agent 12 Tension 13 Ann e de construction 3 3 2 Moteur Le moteur est constitu d un stator et de l ar...

Page 39: ...les l ments sont pr sents En cas d ventuels d fauts il faut pr venir l entreprise en charge du transport ou bien le fabricant le jour m me de la r ception Dans le cas contraire il ne sera pas possible...

Page 40: ...p ex dans un r servoir en mati re synth tique elle s accroche par effet ventouse la surface et ne peut pas pomper Le capteur de d tection doit tre pos sur la surface les lectrodes vers la face inf ri...

Page 41: ...a ma chine Si un flexible est utilis c t pression il doit tre bien rinc l eau claire avant l utilisation afin qu aucun d p t ne puisse entra ner des obstructions Dans l installation immerg e le puisar...

Page 42: ...opri s et tre limin s conform ment aux prescriptions selon la directive 75 439 CEE et d crets selon les art 5a 5b AbfG Loi sur l enl ve ment des d chets Lors des travaux de nettoyage et de maintenance...

Page 43: ...r venir le risque de fragilisation des l ments en lastom re et du rev tement Lors de l entreposage dans des ateliers attention le rayonnement et les gaz qui apparaissent lors du soudage l arc d truise...

Page 44: ...en e pour les r servoirs ou les vannes Amen e bouch e Nettoyer la conduite d amen e les vannes la pi ce d aspiration la tubulure d aspiration et la cr pine d aspiration Rotor h lice bloqu e ou ralenti...

Page 45: ...paritions de traces d usure Remplacer les pi ces us es Palier de moteur d fectueux Contacter l usine Machine soumise des contraintes m caniques lors de son mon tage V rifier le montage utiliser le cas...

Page 46: ...gemene beschrijving 51 3 1 Gebruik 51 3 2 Gebruikstypes 51 3 3 Opbouw 52 4 Verpakking transport en opslag 53 4 1 Aanlevering 53 4 2 Transport 53 4 3 Opslag 53 4 4 Retourneren 53 5 Opstelling en inbedr...

Page 47: ...eel op de werkplek van het product 1 3 Beoogd gebruik De HOMA producten voldoen aan de geldende veilig heidsregels en de stand der techniek Bij toepassing in strijd met het beoogde gebruik kan er leve...

Page 48: ...lificeerde en geautoriseerde perso nen worden uitgevoerd Onderhoudswerkzaamheden en elke vorm van repara tiewerkzaamheden die niet in deze handleiding worden vermeld mogen uitsluitend worden uitgevoer...

Page 49: ...reikt door inbouw van een niveauregistratiesysteem 2 Veiligheid In dit hoofdstuk zijn alle algemeen geldende veiligheids aanwijzingen en technische instructies vermeld Bij trans port opstelling bedrij...

Page 50: ...itsluitend door een gekwa lificeerde elektricien worden uitgevoerd Pas op voor vocht Door het binnendringen van vocht in de kabel raakt de kabel beschadigd en onbruikbaar Daarnaast kan er water in de...

Page 51: ...hting in de vloeistof terechtkomen Gevaar door explosieve vloeistoffen Het verpompen van explosieve vloeistoffen bijv benzine kerosine etc is ten strengste verboden De producten zijn niet ontworpen vo...

Page 52: ...rm 9 Hmax Afvoerhoogte max 10 Qmax Afvoerhoeveelheid max 11 Temperatuur van het op te pompen product 12 Spanning 13 Bouwjaar 3 3 2 Motor De motor bestaat uit een statordeel en de motoras met het loper...

Page 53: ...ringsbewijs of de vrachtbrief 4 2 Transport De producten worden door de fabrikant of de toeleveran cier in een geschikte verpakking aangeleverd Deze sluit normaal gesproken schade bij transport en ops...

Page 54: ...pomp op een vaste niet flexibele bodem worden geplaatst Indien de pomp op een flexibele bo dem bijv in een kunststofcontainer staat zuigt de pomp zich op de bodem vast en kan ze niet afvoeren De sen s...

Page 55: ...oet wor den gereinigd en alle afsluiters moeten worden ge opend Het pomphuis moet overstroomd worden d w z dat het volledig met het medium moet zijn gevuld en dat het geen lucht meer mag bevatten De o...

Page 56: ...n opgevangen en volgens de voorschriften worden af gevoerd volgens richtlijn 75 439 EEG en verordenin gen 5a 5b volgens AbfallGesetz Duitse afvalwet Bij reinigings en onderhoudswerkzaamheden moet de j...

Page 57: ...ing van het huis te voorkomen Let bij opslag in werkplaatsen op het volgende De straling en de gassen die bij het elektrisch lassen ont staan vernielen het elastomeer van de afdichtingen Bij langere o...

Page 58: ...eiding gesloten Afsluiter helemaal openen Waaier propeller geblokkeerd of afgeremd Machine uitschakelen beveiligen tegen opnieuw inschakelen zorgen dat waaier propeller kan draaien Lucht in de install...

Page 59: ...59 Notizen Notes...

Page 60: ...60 Notizen Notes...

Page 61: ...61 Notizen Notes...

Page 62: ...edingte Kontaminierung des Ger tes toxisch nein ja welche Stoffe tzend nein ja welche Stoffe mikrobiologisch nein ja welche Stoffe explosiv nein ja welche Stoffe radioaktiv nein ja welche Stoffe sonst...

Page 63: ...the instruments toxic no yes substance corrosive no yes substance microbiological no yes substance explosive no yes substance radioactive no yes substance other substances no yes substance Legally bi...

Page 64: ...i res corrosives non oui substance mati res micro biologiques non oui substance mati res explosives non oui substance mati res radioactives non oui substance autres substances non oui substance D clar...

Page 65: ...ourneren Contaminatie van het apparaat als gevolg van de toepassing giftig nee ja welke stoffen bijtend nee ja welke stoffen microbiologisch nee ja welke stoffen explosief nee ja welke stoffen radioac...

Page 66: ...66...

Page 67: ...ased the equipment or manufacturer of the equipment Avis DEEE La directive sur les d chets d quipements lectriques et lectroniques DEEE qui est devenue applicable comme loi europ enne le 13 f vrier 20...

Page 68: ...x 49 0 2247 702 44 e Mail info homa pumpen de Internet www homa pumpen de Industriestra e 1 53819 Neunkirchen Seelscheid Telefon 49 0 2247 702 0 Fax 49 0 2247 702 44 e Mail info homa pumpen de Interne...

Reviews: