HOLZMANN Maschinen GmbH www.holzmann-maschinen.at
Strana 36
D 510F
14.1.1
Error - Codes
ERROR - CODES
Error Code Error Solution
01
Hardware Protection Mode
Possible damage to electronic controller
Turn off the machine and re-start once the
digital display has cleared.
If error code still appears the controller
hardware may be damaged and customer
services should be contacted.
02
Software Protection Mode
Possible damage to electronic controller
software
Turn off the machine and re-start once the digital
display has cleared. If error code still appears the
controller software may be damaged and
customer services should be contacted.
03
Low Voltage Abnormality
Protection Mode
Voltage is lower than 165V
It is normal for this error code to appear for a
short period after turning the machine off.
If it appears during operation, turn off the
machine and re-start once the digital display has
cleared.
If error code is still shown the power supply
must be checked and corrected if neccesary.
06
Spindle Direction Protection Mode
The spindle direction has been changed
during operation
Turn off the machine and re-start once the digital
display has cleared.
07
High Voltage Abnormality
Protection Mode
Voltage is higher than 265V
Turn off and and re-start the machine. If error
code still appears, check and correct the power
supply.
08
Motor Speed Protection Mode
Motor speed has been increased sharply,
indicating possible user error.
Turn off the machine and re-start. If error code
still appears, the motor of controller may be
damaged.
MANY POTENTIAL SOURCES OF ERROR CAN BE CLEARED BY THE EXPERTLY CONNECTION TO
THE ELECTRICITY GRID.
Summary of Contents for D 510F