ASSEMBLY
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
26
BS 210TOP / BS 275TOP
12.2
Power supply
ATTENTION
When working with non-grounded machines:
Severe injury or even death may arise though electrocution!
Therefore: The machine must be operated at a grounded power socket
The connection of the machine to the electric power supply and the following checks have to be
carried out by a respectively trained electrician only.
1.
The electronic connection of the machine is designated for operation with a grounded power
socket!
2.
The mains supply must be secured with 16A:
3.
If the connector plug doesn’t fit or if it is defect, only qualified electricians may modify or
re-new it!
4.
The grounding wire should be held in green-yellow.
5.
A damaged cable has to be exchanged immediately!
6.
Check, whether the feeding voltage and the Hz comply to the required values of the
machine. A deviation of feeding voltage of ±5% is allowed (e.g.: a machine with working
voltage of 380V can work within a voltage bandwidth of 370 till 400V.
7.
After connecting, check the right running direction!
8.
Make sure that a possible extension cord is in good condition and suitable for the
transmission of power. An undersized cord reduces the transmission of power and heats up.
9.
A damaged cable must be replaced immediately
NOTICE
Operation is only allowed with safety switch against stray
current (RCD max. stray current of 30mA)
NOTICE
Use only permitted extension cable with cross-section
the one in the following table declared.
Voltage
Extension
Cross-section
220 V-240 V
50 Hz
<27 m
1,5 mm
2
<44 m
2,5 mm
2
<70 m
4,0 mm
2
<105 m
6,0 mm
2
Plug 400V:
5-wire:
with
N-conductor
4-wire:
without
N-conductor
Summary of Contents for BS 210TOP
Page 79: ......