Programming the Essex Keypad

Note

: If the User ID, or User Code/PIN has already been assigned, you will hear one long beep when #  is  entered.

In this case, choose a different User ID /  PIN, or see the instructions for changing or deleting codes. 

DEFAULT USER CODE & MASTER CODE IS “123#”

        1            

The default Master Code is

“123”

.

This can be changed to a unique code 3 - 8 digits long

        2            Enter

*

3 1 2 3 #

                                                                                                      Double Beep      Fast Flash

Solid

        3            Enter 

#

                                                                                                                   Double Beep      Fast Flash

Slow Flash

        4            Enter new master code, followed by

#

                                                                     Triple Beep         Fast Flash

Solid

        5            Enter 

* *

                                                                                                                   Double Beep

        6            EXAMPLE:  old code is 123, new code is 456    

3 1 2 3 # 1 # 4 5 6 # 

* *

Set Master Code

STEP       ACTION                                                                     BEEP          Red LED

Green LED

        1            Remove power 

        2            Jumper the “CONFIG”  pins on the rear of the keypad  .     V = 12

        3            Apply 12 VDC power to red and black wires                                                             Quadruple Beep     Flash       

Solid

        4            Enter 

9 9

followed by

#

                                                                                            Double Beep          Flash                   Solid   

        5            Enter  

2 1 4

followed by

#

                                                                                      Triple Beep            Flash

Solid

        6            Remove power

        7            Remove “CONFIG” jumper

        8            Reapply  power

  STEP    ACTION                                                                     BEEP          Red LED

Green LED

Set Keypad Illumination to 

ON ALL OF THE TIME

TYPE 6.2.0.5-RF

Page 6

Summary of Contents for 400-S12-VIK

Page 1: ...trol Essex stand alone 12 button keypad 1 relay plus 2 grounding outputs external relays required 500 users 12 VDC power supply included INSTALLATION INSTRUCTIONS 501 E Goetz Ave Santa Ana Ca 92707 ww...

Page 2: ...ired from 12v positive to contact common for DC power to strike Essex Keypad Wiring DC Out for Gate Strike Page 2 Type 6 2 0 5 RF NOTE Talk Battery switch must be in ON position when the C 1000B is us...

Page 3: ...when the C 1000B is used w o a CO line input Gate Motor VIKING Model C 1000B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 EARTH GND PHONE LINE INPUT LINE OUT TO PHONES KEYLESS CONTACT DOOR BOX 1 DO...

Page 4: ...ON 10 ON ON 30 C 1000B Door Controller Programming 1 Disconnect the PHONE LINE INPUT 2 Slide the TALK BATTERY switch to the ON position 3 Move DIP SWITCH 2 from OFF to ON 4 Connect a phone to termina...

Page 5: ...ition 2 Move DIP SWITCH 2 from ON to OFF 3 Re connect the PHONE LINE INPUT and LINE OUT TO PHONES Return to normal use mode Step Action OPERATION OF C 1000B ANSWER A CALL FROM DOORBOX When the phones...

Page 6: ...Beep Fast Flash Slow Flash 4 Enter new master code followed by Triple Beep Fast Flash Solid 5 Enter Double Beep 6 EXAMPLE old code is 123 new code is 456 3 1 2 3 1 4 5 6 Set Master Code STEP ACTION B...

Page 7: ...Triple Beep Slow Flash Slow Flash 10 Enter Double Beep X 2 Set User Codes STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step Master Code 123 is used as an example 2 Ente...

Page 8: ...e programming Triple Beep Slow Flash Slow Flash 7 Enter Double Beep X 2 Deleting User Codes using User Code PIN STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step In thi...

Page 9: ...Double Beep Slow Flash Slow Flash 4 Enter the desired activation time in Seconds followed by Triple Beep Slow Flash Solid 5 Enter to exit 6 Example 2 10 10 second activation time Setting Main Relay O...

Page 10: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Reviews: