TyPE 6.2.0.8-RF

Programming the Essex Keypad

* Note

: If the User ID, or User Code/PIN has not been assigned, you will hear one long beep 

when #  is entered.  

1

The Master Code is necessary to do this step.

In this example, the Master Code is 123

2

Enter 

*

1 1 2 3 

#

Double Beep          Slow Flash 

Solid

3

Enter 

5

#

Double Beep 

Slow Flash 

Slow Flash

4

Enter User Code/PIN to be changed, followed by 

#

Double Beep          Slow Flash 

Fast Flash

5

Enter new User Code/PIN, followed by

#

Double Beep          Slow Flash 

Fast Flash

6

Enter 

#

to complete  programming

Triple Beep

Slow Flash       Slow Flash

7

Enter 

* * * *

Double Beep X 2

Deleting User Codes - using User Code/PIN  

STEP

ACTION                                                                     BEEP          Red LED

Green LED

1

The Master Code is necessary to do this step.

In this example, the Master Code is 123

2

Enter

*

1 1 2 3 

#

Double Beep

Slow Flash

Solid

3

Enter 

#

Double Beep          Slow Flash

Slow Flash

4

Enter 1st User ID to be deleted (1-500), followed by 

#

Triple Beep             Slow Flash

Fast Flash

5

Enter 2nd User ID to be deleted (1-500), followed by 

#  

Triple Beep

Slow Flash 

Fast Flash

.                                     

6

Enter 

* * * *

Double Beep X 2

Deleting User Codes  - using User ID  

STEP

ACTION                                                                     BEEP          Red LED

Green LED

N

N

N

N

Example for deleting user code # 456-  

* 1 1 2 3 # 5 # 4 5 6 # 7 8 9 # # * * * *  

Example for deleting user ID 1 and 2-  

* 1 1 2 3 # 4 #1 # 2 # * * * *  

Summary of Contents for 400-S12-PAN2

Page 1: ...er supply included INSTALLATION INSTRUCTIONS 501 E Goetz Ave Santa Ana Ca 92707 www eholovision com Ph 714 434 6904 Fax 800 362 0002 HOLOVISION Not Used 12 VDC input for camera and keypad NO COM NC re...

Page 2: ...ack which can be created when power is removed from the strike Loop is required from 12v positive to contact common for DC power to strike Essex Keypad Wiring DC Out for Gate Strike Page 2 Type 6 2 0...

Page 3: ...Contact Closure for Gate Operation Page 3 Type 6 2 0 8 RF To Phones Refer to manual pages 6 8 for details Cut for NO Contact Closure AC Loop for Strike Gate Motor PAN 2 9V DC NOTE This connection is...

Page 4: ...Beep Fast Flash Slow Flash 4 Enter new master code followed by Triple Beep Fast Flash Solid 5 Enter Double Beep 6 EXAMPLE old code is 123 new code is 456 3 1 2 3 1 4 5 6 Set Master Code STEP ACTION B...

Page 5: ...Triple Beep Slow Flash Slow Flash 10 Enter Double Beep X 2 Set User Codes STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step Master Code 123 is used as an example 2 Ente...

Page 6: ...e programming Triple Beep Slow Flash Slow Flash 7 Enter Double Beep X 2 Deleting User Codes using User Code PIN STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step In thi...

Page 7: ...Double Beep Slow Flash Slow Flash 4 Enter the desired activation time in Seconds followed by Triple Beep Slow Flash Solid 5 Enter to exit 6 Example 2 10 10 second activation time Setting Main Relay O...

Page 8: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Reviews: