LED IMPORTANT SAFETY INSTRUCTIONS 

 

 
 
 

 
 

 

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and 
other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.   

 

Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. 

 

Installation and service of luminaires should be performed by a 

qualified licensed electrician

.  

 

Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation 
and any hazards involved.  Regular fixture maintenance programs are recommended.  

 

It will occasionally be necessary to clean the outside of the refractor/lens.  Frequency of cleaning will depend on ambient 
dirt level and minimum light output which is acceptable to user.  Refractor/lens should be washed in a solution of warm 
water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.  Should optical assembly 
become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.  

 

DO NOT INSTALL DAMAGED PRODUCT!  

This luminaire has been properly packed so that no parts should have been 

damaged during transit. Inspect to confirm.  Any part damaged or broken during or after assembly should be replaced.

 

 

Recycle: For information on how to recycle LED electronic products, please visit 

www.epa.gov

.     

 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency 

to meet in connection with installation, operation, or maintenance.  Should further information be desired or should 
particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be 
referred to Acuity Brands Lighting, Inc.  
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! 

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION 

 

 

Disconnect or turn off power before 

installation or servicing. 

 

Verify that supply voltage is correct by 

comparing it with the luminaire label 

information. 

 

Make all electrical and grounded 

connections in accordance with the National 

Electrical Code (NEC) and any applicable 

local code requirements. 

 

All wiring connections should be capped 

with UL approved recognized wire 

connectors. 

 

WARNING 

RISK OF ELECTRIC SHOCK 

 

 

Allow lamp/fixture to cool before handling. 

Do not touch enclosure or light source. 

 

Follow all manufacturer’s warnings, 

recommendations and restrictions for: driver 

type, burning position, mounting 

locations/methods, replacement and 

recycling.    

 

 

 

 

 

 

WARNING 

RISK OF BURN 

 

 

 

Wear gloves and safety glasses at all times 

when removing luminaire from carton, 

installing, servicing or performing 

maintenance. 

 

Avoid direct eye exposure to the light source 

while it is on. 

 

CAUTION 

RISK OF INJURY 

 

 

 

Keep combustible and other materials that 

can burn, away from lamp/lens.   

 

Do not operate in close proximity to 

persons, combustible materials or 

substances affected by heat or drying.  

 

 

CAUTION 

RISK OF FIRE 

Summary of Contents for Petrolux LED Low Bay Adapter

Page 1: ...D electronic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes this matter sho...

Page 2: ...on Unless individual product specifications deem otherwise Never connect an LED product directly to a dimmer packs occupancy sensors timing devices or other related control devices LED fixtures must be powered directly off a switched circuit Unless individual product specifications deem otherwise Do not restrict fixture ventilation Allow for some volume of airspace around fixture Avoid covering LE...

Page 3: ...er les produits électroniques à DEL visitez le site www epa gov Ces instructions ne prétendent pas couvrir tous les détails ni toutes les variantes de ces appareils ni prévoir toutes les éventualités pouvant survenir lors de leur installation leur utilisation et leur entretien Pour obtenir plus d informations ou pour résoudre des problèmes insuffisamment traités par rapport aux besoins de l achete...

Page 4: ... matériau pouvant limiter le refroidissement par conduction ou par convection À moins que des spécifications particulières au produit ne l exigent Ne pas dépasser la température ambiante maximale de service admissible N utiliser le luminaire qu à son emplacement prévu Décharge électrostatique DES Une DES peut endommager les luminaires à DEL Un équipement personnel de mise à la terre doit être port...

Page 5: ...rk OH 43058 3004 740 345 9631 2 Installation 2 1 Tools and Materials Required TABLE 1 Installation Tools and Materials DESCRIPTION USE 5 16 socket Shield Bracket Screw 3 8 socket Closure Screw 2 2 Existing Luminaire Removal 2 2 1 Disconnect power to luminaire location 2 2 2 Remove existing luminaire keeping mounting cover in place Mounting cover must be suitable to support PXLW luminaire See table...

Page 6: ... ground connections to the luminaire wires in accordance with local codes inside PXLW luminaire wiring chamber Bypass any existing fuses fuseholders or photocells Use purple and grey wires on PXLW luminaire to make dimming connections if provided See section 4 for backup battery option Cap any leads from PXLW luminaire or existing wiring that are not in use 3 1 5 If mounting the PXLW luminaire to ...

Page 7: ...dirt and debris using a soft clean cloth A mild detergent and water may be used if necessary CAUTION DO NOT USE ABRASIVE CLEANERS ON OPTICAL SURFACES THEIR USE MAY RESULT IN THE LOSS OF OPTICAL EFFICIENCY MISE EN GARDE NE PAS UTILISER DE NETTOYANT ABRASIF SUR DES SURFACES OPTIQUES LEUR UTILISATION PEUT ENTRAÎNER UNE PERTE D EFFICACITÉ OPTIQUE 6 3 Optic Replacement Figure 6 6 3 1 Disconnect power t...

Page 8: ...nts using Holophane approved replacement parts 6 4 4 Examine the condition of electrical cover gasket and gasket joint surfaces 6 4 5 Re connect electrical components 6 4 6 Close luminaire and tighten closure screw to torque specified in Figure 1 A 7 Limited Warranty and Limitation of Liability The Holophane limited warranty and limitation of liability is published in the Terms and Conditions docu...

Page 9: ... WL SA UN N A Type 1 GH CE W ST P B C D A Appleton Mercmaster II ARAPMM2 PXLHARAPMM2 LPA 75 LPC 75 LPWB 75 LPS 125 N A N A Type 2 LPA 100 LPC 100 LPWB 100 LPS 150 Appleton Mercmaster III ARAPMM3 PXLHARAPMM3 KPA 75 100 KPC 75 KPWB 75 KPS 125 N A N A Type 2 KPAF 75 100 KPC 100 KPWB 100 KPS 150 KPCH 75 100 KPST 125 KPST 150 Killark Certilite ARKL PXLHARKL VMA2B VMX2B VMB2B VMD4B N A N A Type 3 VMA 2 ...

Page 10: ...10 P a g e IM 456 A Figure 7 Wiring Diagrams ...

Page 11: ...11 P a g e IM 456 A ...

Page 12: ...12 P a g e IM 456 A Figure 8 Mounting Cover Examples Type 1 Mounting Screw Type 2 Mounting Screw Type 3 Mounting Screw ...