Figure 2 

 

 

GR2120 

 

2.4  Architectural Arm Mounting

 

 

2.4.1 

Loosen the screw holding the wire chamber cover in place 

and remove the cover. 

2.4.2 

   Start one of the mounting bolts in the hole that corresponds 

to the keyway in the fitter. 

2.4.3 

Place supplied gasket between arm and pole. See Figure 3. 

2.4.4 

Line up the keyway with this bolt and use it to hang the 

fixture.  See Figure 3. 

2.4.5 

Tighten the bolts from 15-17 ft-lbs. 

2.4.6 

Follow steps 2.2.5.

 

 

Figure 3 

 

 

GR2119 

 

2.5 Photocontrol Option

 

Skip to next step if unit does not have a photocontrol receptacle.  
 

2.5.1 

Locate the photocontrol receptacle on the top of the unit and 

remove protective cover.  Loosen the two screws and rotate the 
receptacle until it points north.  Retighten the screws. Install a twist-on 
type photocontrol into the receptacle. 

 

2.6 Tilt Adjustment 
 
2.6.1 

Loosen the tilt adjustment bolts until the body of the fixture is 

free to rotate on the flange of the fitter.

 

2.6.2 

Using the top of the fitter flange as a guide, rotate the fixture 

body to the desired tilt setting.  See figure 4.

 

2.6.3 

Tighten the bolts to 20 ft-lbs

 

 
 
Figure 4 

 

GR2121

 

 

 

3 MAINTENANCE 
 

 

3.1  Cleaning of Luminaire

 

 

3.1.1 

Wipe off exterior dirt and debris using a soft clean cloth.  A mild 

detergent and water may be used if necessary. 
 

CAUTION 

DO NOT USE ABRASIVE CLEANERS ON OPTICAL 
SURFACES.  THEIR USE MAY RESULT IN THE LOSS OF 
OPTICAL EFFICIENCY. 

  

3.2 Electrical Component Replacement 
 
3.2.1 

Disconnect power to the unit prior to opening and performing 

any maintenance

.

 

3.2.2 

Access to the LED modules should be performed by qualified 

personnel experienced with solid state lighting only.  Contact factory 
for support. 

3.2.3 

Surge Protector Replacement:  See Figure 5.  Locate the surge 

protector.  Disconnect the surge protector via the wiring quick 
disconnects.  Remove the screws holding the surge protectors in place 
and retain.  Carefully remove the surge protector and install the new 
Holophane approved surge protectors in the same orientation with the 
original screws.  Re-connect the surge protectors’ quick disconnects.   

3.2.4 

LED Driver Replacement:  Before removing components, 

disconnect driver input and output leads nearest the driver via the 
quick disconnects.  Remove the (4) driver screws to remove the driver 
from the electrical door; retain screws for reuse.  Install new 
Holophane approved driver and tighten screws securely.  Reconnect 
all driver input and output leads.   