background image

 

 

IM-182 

Caution 

Field application of Pipe Thread Sealant is 

required.  Failure to properly apply pipe thread 

sealant could cause this unit to leak. 

 
Figure 2 

 

 

GR1060

 

2.2.3 

Loosen ballast assembly door screw, remove two hinge 

screws at the rear of the ballast assembly door on the outside of the 
arm to remove ballast assembly door. 

2.2.4

  Connect the wires from the optical assembly to the wires 

from the arm assembly.  Connect green wire to green wire, white 
wire to white wire, and black wire to black wire. 

2.2.5 

With ballast assembly door removed, attach and level 

luminare to the pole using mounting bolt pattern at the rear of the 
arm assembly. On units using a tenon fitter tighten set screws at the 
base of the tenon fitter to 10-12 foot pounds. See figure 3. 

2.2.6

 Connect electrical supply wires to the terminal block inside the 

arm assembly. The terminals are marked “L1” (line1). “G” (Ground). 
“L2” (line2). If one of the supply wires is electrically neutral, it should 
be connected to terminal “L2”.  

2.2.7

 Open the wire chamber cover by loosening the door screw.  

Connect the male wiring harness connector from the optical assy.  to 
the female wiring harness connector from the ballast assy. close the 
ballast compartment door and tighten the screw. See figure 4. 

2.2.8

 Tighten door screw on ballast assembly door to 10-12 foot 

pounds. See figure 4. 

2.2.9

 Open lamp chamber by loosening the refractor door screw 

and swing down refractor. Refer to Figure 1. 

 
3. MAINTENANCE

 

 
3.1 Relamping and Cleaning. 
3.1.1

 Wipe off exterior dirt and debris. 

3.1.2

 Open lamp chamber by loosening the refractor door 

screw and swing down refractor. Refer to Figure 1. 

3.1.3

 Remove lamp. 

3.1.4

 Wipe out the refractor interior with a clean dry cloth. 

3.1.5

 Install new lamp of correct wattage and type. Tighten 

the lamp carefully but securely. 

3.1.6

 Close lamp chamber by swinging up the refractor and 

tightening the refractor door screw. 

3.1.7

 Energize the luminaire. Check for proper operation.  

3.2 Replacement Ballast Assembly. 
3.2.1

 Loosen ballast door screw at optical assembly end of 

luminaire. Refer to Figure 4. 

Figure 3 

 

 

GR1101

 

Figure 4 
 

 

GR2004 

3.2.2

 Swing down ballast assembly door with one hand and use 

other hand to disconnect the male wiring harness connector. 

3.2.3 

Remove ballast assembly door refer to section 2.2.3 

3.2.4

 Unscrew (2) ballast mounting strap screws located to the rear 

of the ballast assembly door they are the screws attaching the ballast 
strap to the door assembly, remove ballast. 

3.2.5

 Unpack replacement ballast assembly. Check voltage 

leads. 

3.2.6

 Replace the ballast assembly and reinstall the ballast-

mounting strap. 

3.2.7

 Reconnect the male wiring harness connector to the female 

wiring harness connector, reattach the ballast door assembly and 
swing ballast assembly door completely closed 

3.2.8

 Tighten ballast door screw to 10-12 ft.-lbs. 

3.2.9

 Energize the luminaire. Check for proper operation. 

 

4. Limited Warranty and Limitation of Liability 

The Holophane limited warranty and limitation of liability is published 
in the "Terms and Conditions" section of the current Holophane 
buyer's guide, and is available from your local Holophane sales 
representative. 

®

 