HOLOPHANE Madeira Installation And Maintenance Manual Download Page 2

 

 

IM-180 

Figure 1 

 

                                                                                                           GR694 

2.2.8

 Place the lamp access cap over the top opening.  Verify the 

cap screws are under the retaining lip.  Tighten the four cap 
screws.  See Figures 2. 

2.2.9 

Energize the fixture and check for proper operation. 

 
3.  MAINTENANCE 
 
3.1  Re-lamping and Cleaning 
 
3.1.1

 Wipe off exterior dirt and debris from the glass surfaces 

using a soft, clean cloth.  Detergents and cleaning solvents will not 
harm the glass, but should be used carefully around gasket 
materials.   
 

CAUTION 

DO NOT USE ABRASIVE CLEANSERS ON OPTICAL 

SURFACES.  THEIR USE MAY RESULT IN THE LOSS OF 

OPTICAL EFFICIENCY. 

 

3.1.2 

Remove the top lamp access cap, by loosening the four 

screws.

  

Lift up on cap.  See Figure 2. 

3.1.3 

Remove the lamp and dispose of it in a safe and proper 

manner. 
 
Figure 2 

 

 

 GR1094 

3.1.4 

Install the proper lamp type.  Tighten the lamp carefully but 

securely. 

3.1.5

 Re-install the lamp access cap and tighten the four cap 

screws. 

3.1.6

 Energize the fixture and check for proper operation. 

 
3.2  Electrical Component Replacement 

 

3.2.1

 

 Loosen the two screws securing the housing door and 

slide the electrical module out until the retaining hook on the 
module engages the housing bracket.  (See Figure 1.) 

3.2.2

 

 Unplug the electrical disconnect, disengage the retaining 

hook from the housing bracket and remove the electrical module. 
 

NOTE 

The entire electrical module can be replaced by another 

module,  allowing maintenance on the original electrical 

module to be performed in the shop.  If a complete 

replacement electrical module is being used, skip to step 

3.2.6 

 

3.2.3

  Tag all leads that will be disconnected and note the 

orientation and position of all components that will be replaced and 
the fasteners holding them.  Remove the component(s) to be 
replaced. 

NOTE 

The capacitor may be removed simply by disengaging the hook on 

the end of the coiled wire bracket from the top lip of the capacitor 

and lifting the capacitor out of the coiled wire bracket. 

 

3.2.4 

Use components supplied by Holophane.  Place the new 

components exactly as were the original components and reuse 
the original fasteners to secure them.  Check for pinched wires 
before tightening down the replacement components.  Tighten all 
fasteners firmly.  Bundle and secure the wiring in a manner similar 
to the way it was originally secured to avoid pinching of wires when 
reinstalling the module into the housing.  Replace all 
shields/insulation as originally installed. 

3.2.5

  Re-install the electrical module by, lifting it to the opening 

of the housing, and engage the retaining hook on the housing 
bracket.  Plug in the keyed electrical disconnect, being certain that 
the snap lock engages on the disconnect latches.  (See Figure 1). 

3.2.6

  

Lift the module and insert it into the housing and tighten 

the door screws to 4-6 ft. lbs.   

3.2.7

  Energize the fixture and check for proper operation. 

 

4.   LIMITED WARRANTY AND   
      LIMITATION OF LIABILITY 

 

The Holophane limited warranty and limitation of liability is 
published in the "Terms and Conditions" section of the current 
Holophane buyer's guide, and is available from your local 
Holophane sales representative. 

®

 

 

Acuity Lighting Group, Inc. 

214 Oakwood Ave., Newark, OH 43055 
 
IM-180 7/02 ©2002 Acuity Lighting Group Inc. 
 

Visit our web site at www.holophane.com 

Printed in USA 