1. INTRODUCTION
1.1 Product Description.
•
This product is designed to include most of the standard
medium- and mogul-base HID lamps up to 400 watts.
•
All the electrical control gear is mounted to the housing door
which may be completely removed from the fixture by
loosening two screws and unplugging a single electrical
disconnect.
1.2 Alternate Information Sources.
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(866)759-1577
2. INSTALLATION
2.1 Tools and Material Required.
Table 1. Installation Tools and Materials
DESCRIPTION
USE
Flat-end screwdriver
Door Screws/Finial cap
3/16" Allen wrench
3/8” set screws in pole fitter
Torque wrench
Set screws
2.2 Fixture Installation.
2.2.1
Loosen the housing door screws and slide out the electrical
module. There is a retaining hook on the bottom of the module
that may engage the bracket on the housing; if so, manipulate the
module to disengage the hook and set the module aside. (See
Figure 1.)
2.2.2
Feed the supply wiring up through the slipfitter into the
electrical chamber as you set the fixture on its mounting (bracket,
tenon, pole top), being careful not to pinch the supply wires.
Orient and level the fixture before tightening all six setscrews. If
the unit is supplied with a photocontrol, the photo eye should be
oriented in a northerly direction. Alternate tightening of the screws
will assist in leveling and insuring proper attachment of the fixture.
Tighten the set screws to 15 ft. lbs.
OPTICS ORIENTATION NOTES
Some of the fixtures in this series are equipped with optical
components that produce distributions of light that are not
symmetric and are intended to be aimed by orienting the prismatic
refractor a specific direction. The “Street Side” marking on the
housing should be pointed toward the street. (See Figure 2.)
2.2.3
Secure the supply wires to the fixture by tying them or
installing a strain relief clamp.
2.2.4
Connect the electrical supply wires to the terminal block in
the back of the electrical chamber. The terminals are marked “L1”
(Line 1), “G” (Ground), and “L2” (Line 2). If one of the supply lines
is electrically neutral, it should be connected to terminal “L2”.
Dress the wiring neatly against the rear of the chamber to allow
the installation of the electrical module.
2.2.5
Lift the electrical module to the opening of the housing and
engage the retaining hook on the housing bracket. Plug in the
keyed electrical disconnect, being certain that the snap lock
engages on the disconnect latches.
2.2.6
Lift the module and insert it into the housing and tighten
the door screws to 4-6 ft. lbs.
2.2.7
Install the proper lamp type through the opening in the top
of the unit. Tighten the lamp carefully but securely.