1.  INTRODUCTION 
 
1.1  Product Description.  

 

• 

This product is designed to include most of the standard  
medium- and mogul-base HID lamps up to 400 watts. 

• 

All the electrical control gear is mounted to the housing door 
which may be completely removed from the fixture by 
loosening two screws and unplugging a single electrical 
disconnect. 

 

1.2  Alternate Information Sources. 

  

 

Holophane 

Field Service Department 

P.O. Box 3004 

Newark, OH  43058-3004 

(866)759-1577 

 

2.  INSTALLATION 

 

2.1  Tools and Material Required. 

 

Table 1.  Installation Tools and Materials

 

DESCRIPTION 

USE 

Flat-end screwdriver 

Door Screws/Finial cap 

3/16" Allen wrench 

3/8” set screws in pole fitter 

Torque wrench 

Set screws

 

 

2.2  Fixture Installation. 

 

2.2.1

 

 Loosen the housing door screws and slide out the electrical 

module.  There is a retaining hook on the bottom of the module 
that may engage the bracket on the housing; if so, manipulate the 
module to disengage the hook and set the module aside.  (See 
Figure 1.) 

2.2.2

  

  Feed the supply wiring up through the slipfitter into the 

electrical chamber as you set the fixture on its mounting (bracket, 
tenon, pole top), being careful not to pinch the supply wires.  
Orient and level the fixture before tightening all six setscrews.  If 
the unit is supplied with a photocontrol, the photo eye should be 
oriented in a northerly direction.  Alternate tightening of the screws 
will assist in leveling and insuring proper attachment of the fixture.  
Tighten the set screws to 15 ft. lbs. 
 

OPTICS ORIENTATION NOTES 

Some of the fixtures in this series are equipped with optical 
components that produce distributions of light that are not 
symmetric and are intended to be aimed by orienting the prismatic 
refractor a specific direction.  The “Street Side” marking on the 
housing should be pointed toward the street.  (See Figure 2.) 
 

2.2.3

  Secure the supply wires to the fixture by tying them or 

installing a strain relief clamp. 

2.2.4  

Connect the electrical supply wires to the terminal block in 

the back of the electrical chamber.  The terminals are marked “L1” 
(Line 1), “G” (Ground), and “L2” (Line 2).  If one of the supply lines 
is electrically neutral, it should be connected to terminal “L2”.  
Dress the wiring neatly against the rear of the chamber to allow 
the installation of the electrical module. 

 

2.2.5  

Lift the electrical module to the opening of the housing and 

engage the retaining hook on the housing bracket.  Plug in the 
keyed electrical disconnect, being certain that the snap lock 
engages on  the disconnect latches. 

2.2.6

  Lift the module and insert it into the housing and tighten 

the door screws to 4-6 ft. lbs. 

2.2.7 

Install the proper lamp type through the opening in the top 

of the unit.  Tighten the lamp carefully but securely. 