IM-207-I
Figure 1
GR1334B
2.3.3 Illuminaire or Illumibay Wiring:
2.3.3.1 MH Electro Magnetic, MH Electronic, Inc,
EM & ER:
Splice the wires from the optical to
electrical housing as follows: attach black leads to
black leads, white to white and green to green. If the
optical assembly is supplied with the EM or ER
option, splice “INC” to “INC” two places. For Illumibay
ER option, splice Red lead with “INC” on optical end
two places. Other ends will be spliced in conduit box
provided.
MH electronic ballast
: Attach White connectors
between optic assembly and electrical housing
assembly, carefully place white connector into optical
husk wiring chamber. See figure. 3 & 4.
Dimming Option Wiring Connection
Dimming voltage operate between 0-10 Volt DC.
Separate dimming leads from main power leads.
Tie dimming leads around the hook assembly with
wire tie. Connect Dimming Leads as shown in
figure 5.
(
Polarity is very impotant when connecting
dimming leads)
2.3.3.2 Single Compact Fluorescents:
Single lamp
CFL units may be spliced using color coding to
match. Carefully place splices into optical husk wiring
chamber.
2.3.3.3: Multiple Compact Fluorescents:
For dual
lamp units, the units need to be spliced following the
diagram provided in Fig. 2. For units with more than
two sockets and the 120W CFL,
connect electrical
housing plug to optical receptacle securely. Carefully
push wires up into the electrical housing.
Figure 2
GR1347
2.3.4
Lift optical from this temporary hanging position
and insert into the opening of the electrical housing.
There are protruding lugs that must match up to the
openings in the optical husk.
2.3.5
Carefully line up the lugs with the openings and
push optical into opening. When fully inserted in the
electrical housing, twist clockwise to engage.
2.3.6
Carefully release the optical after insuring that it
has engaged the lugs securely. Tighten set screw
securely to lock the optical from turning or becoming
loose.
2.4 Lamp Installation
2.4.1 Illuminaire
2.4.1.1
Remove relamp door by turning counter-
clockwise. Allow door assembly to hang on cable
provided while lamping. Install proper lamp type (See
relamp information on the optical assembly) and
tighten lamp securely into socket.
2.4.1.2
Install relamp door by pushing relamp cable
up into opening while inserting threaded neck into the
metal receiver in the optical assembly and twist in a
clockwise direction until it seats completely. Do not
over-tighten.
2.4.2 Enclosed Illumibay
2.4.2.1
Open enclosed door by carefully releasing the
two clips holding the door shut. With you holding the
door gently let the door swing to a vertical position
and let hang while lamping. Install proper lamp type
(See relamp information on the optical assembly) and
tighten lamp securely into socket.
WARNING: FAILURE TO TIGHTEN SET SCREW
MAY RESULT IN INJURY OR DEATH OR
SIGNIFCANT PROPERTY DAMAGE.