IM-207-I
HOLOPHANE
®
Illuminaire
®
/ Illumibay
®
Installation and
The New Shape of Light
®
Maintenance
Integral Ballast Version
Manual
Manual
AFTER INSTALLATION DELIVER THIS
MANUAL TO OWNER
IMPORTANT SAFETY INSTRUCTIONS
WARNING
–
READ THESE INSTRUCTIONS
CAREFULLY BEFORE ATTEMPTING TO INSTALL OR
MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY
QUALIFIED PERSONNEL.
WARNING
– BE CERTAIN THAT ALL ELECTRICAL
POWER IS DISCONNECTED FROM THE FIXTURE
BEFORE INSTALLING OR MAINTAINING THE FIXTURE.
WARNING –
FOLLOW LAMP MANUFACTURER’S
OPERATING AND MAINTENANCE INSTRUCTIONS.
FAILURE TO FOLLOW THESE WARNINGS MAY
RESULT IN DEATH, INJURY OR SIGNIFICANT
PROPERTY DAMAGE.
GR1291 / GR1554
1 INTRODUCTION
1.1 Product Description
. The Illuminaire / Illumibay
series lighting fixtures have been listed to
applicable U.S. and Canadian safety standards
by Underwriters Laboratories Inc. They are
suitable for use in damp locations, and ambient
temperatures to 40 degrees Celsius.
1.2 Alternate Information Sources
. If additional
questions arise relative to this lighting fixture that this
document or your supplier cannot answer, please
refer them to :
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(866) 759-1577
2 INSTALLATION
2.1 Tools and Materials Required
.
TABLE 1. Installation Tools and Materials
DESCRIPTION USE
Philips head screwdriver
Electrical housing cap
Socket and wrench set
Optical hanging bolt &
Electrical
disassembly
Allen wrench set
Optical set screw
WARNING:
DO NOT SUSPEND THE LUMINAIRE SOLEY FROM A
OUTLET BOX. THE LUMINAIRE WEIGHT EXCEEDS
THE 50# CAPACITY OF OUTLET BOXES. FAILURE TO
PROVIDE ADDITIONAL SUPPORT MAY RESULT IN
INJURY OR DEATH OR SIGNIFICANT PROPERTY
DAMAGE.
2.2 Electrical Assembly Installation
SEE FIGURE 1
2.2.1
Loosen two screws holding electrical housing
cap in place. Rotate and lift off.
PF Option or other hanging device
.
2.2.2
Slip hanging device or PF through center hole
of electrical housing cap and apply 4-5 drops of the
thread locking liquid (provided) to threads of pipe and
screw pipe in approximately ½ inch, this equals 7
threads tightening securely. (Wipe away excess
adhesive that may have squeezed out.)
2.2.3
Route wires through pipe to top of electrical
housing and make wire connection in accordance
with approved wiring methods.
2.2.4
Reinstall electrical housing cap and tighten
screws. Tighten safety screw securely.
2.2.5
Hang the electrical housing to a secure location
capable of withstanding 75 lbs. Tighten safety screw
securley.
2.3 Optical Assembly Installation.
2.3.1
Remove the
optical hanging bolt from parts bag
located in the wiring area of the optical husk. It will
self-thread into hole provided on top of the optical
husk. Tighten securely.
2.3.2
Lift optical and place optical hanging bolt in the
slot provided for it in the electrical housing. This will
provide a temporary means of hanging while the
wiring connections are made. (See Fig. 1 Assembled
View)