6 |
P a g e
POWER, DISPLAY MODE / MENU,
OVER SAMPLING / ←
,
SOURCE/→
Left of display:
(Indication light is RED when powered in Off-State, and GREEN when ON)
Press and hold this button for 1 second to switch the
power on and off. In the off state, all is power is off except for the standby circuit and red indication light, other
circuits of the May "
梅
" will stop working and stop outputting.
Right of display, 4 buttons from left to right:
In the silent mode, some of the May "
梅
" output stage circuit turns off. However, the power
consumption is essentially unchanged, and will maintain its
hot
machine state.
In normal operation (display) mode, press this button to select whether to turn off
the display automatically; in configuration (menu) mode, press this button to select the configuration item.
←
In Normal (over-sampling) mode, press this button to select oversampling mode. In
configuration mode, press this button to change the configuration mode (left).
→
In Normal mode, press this button to select the digital source. In configuration mode, press
this button to change the configuration mode. Select the digital input source, including USB (ground isolated), RCA,
BNC, AES, fiber optic, I2S-1 and I2S-2.
Summary of Contents for May