Remove the dust caps from the female and male couplers.
•
Check the couplers for dirt and damage and clean them if necessary.
•
Screw the male coupler into the female coupler and tighten the locking ring as far as possible.
•
Screw the dust caps together, to prevent from contamination.
5.2.3
Connect the Quick-Lock couplers
Refer to Fig. 8.
•
Turn the retainer ring on the female coupler anti-clockwise to unsecure the lock ring.
•
Remove the dust cap from the female coupler by pushing back the lock ring. The dust cap slips off.
•
Pull the dust cap from the male coupler.
•
Check the couplers for dirt and damage and clean them if necessary.
•
Push the lock ring on the female coupler backwards.
•
Push the couplers into each other and the lock ring of the female coupler will automatically lock.
•
Check whether the couplers can not be pulled apart with a normal manual effort and turn the
retainer ring clockwise so that the lock ring is secured.
•
Connect the dust caps together.
5.3
Disconnect the hydraulic hoses
5.3.1
General
5.3.2
Disconnect the High-Flow couplers
Refer to Fig. 9.
•
Disconnect the dust caps from each other.
•
Unscrew the locking ring. The male coupler will be released.
•
Clean the couplers and the dust caps.
•
Replace the dust caps on the female and male couplers.
5.3.3
Disconnect the Quick-Lock couplers
Refer to Fig. 10.
WARNING
Always make sure that the pressure relief valve is in the "neutral" position, before you
connect hydraulic hose(s) to the pump.
WARNING
Always make sure that the pressure relief valve is in the "neutral" position, before you
connect hydraulic hose(s) to the pump.
Caution
Never use pliers or similar to disconnect the hydraulic couplers.
WARNING
Always make sure that the pressure relief valve is in the "neutral" position, before you
disconnect hydraulic hose(s) from the pump.