Holman iweather WS109A Instruction Manual Download Page 15

13

PC Connection

As an important feature in addition to the display on the Touch Screen, the Weather Station allows the read-out of all 
measured and displayed time and weather data in form of complete history data sets on a PC.

   

 

Data Storage 

For a comprehensive weather history, the Base Station allows the internal storage of up to 4080 complete sets of 
weather data with time and date. The base station will loose all weather data if an interruption of power supply. In case 
the memory capacity of the Weather Station is exhausted the oldest data sets stored will be overwritten by the new 
ones entered.

   

 

Data Recall 

Certain weather data or setting values can only be read out, processed, and displayed by means of a PC. Also the 
settings of the storing intervals from 5 minutes to 240 minutes for the storage of data sets can only be performed by 
means of a PC.   
 

Connections and Software

The wiring between Weather Station and PC takes place by means of an included USB cable.  The EasyWeather 
software package, also included in the shipping contents, must be installed on the PC.   
This software allows the display of all present weather data with graphic symbols. It also allows the display, storage, 
and printing of history data sets, whose volume exceeding the maximum 4080 data sets of the Weather Station is only 
limited by the capacity of the PC’s main memory. 

PC software installation

The installation of software is very simple: double click the setup.exe file and follow the steps popped up. 

Make sure you are running the program under the administrator accounts of your windows PC platform. Otherwise the 
graphic function might not be working when graph display mode is needed to display all history data.

If you run the program for the first time, the current weather display will be displayed and at the sub line of the window, 

the program will show related information regarding the read of all history data into the PC. Please note however, when 
there is large amount of data is being uploaded, it will take a few minutes time before the system can respond to your 
setup settings. Otherwise it will display “read weather data fail” error message since the USB port is reading the data 
from the memory and the system is not able to respond any further job tasks.

When memory is full, it will take about two minutes to upload all history data into PC and it takes another two minutes to 
process all history data for graphic display. Further detailed PC software user manual can be found from the help menu.

WS109A Manual.indd   15

26/07/13   5:01 PM

Summary of Contents for iweather WS109A

Page 1: ...Instruction Manual Product Code WS109A For more information regarding this product and to view the full iWeather product range please scan the QR code with your mobile device...

Page 2: ...15 Function Button display and system setup configuration 16 Function Button display and system setup alarm value 16 Function Button display Min and max recorded value 17 Function Button display list...

Page 3: ...suring range rel humidity 10 99 Resolution 1 Measuring range air pressure 300 1100hPa 8 85 32 5inHg Accuracy 3hpa under 700 1100hPa Resolution 0 1hPa 0 01inHg Alarm duration 120 sec Power consumption...

Page 4: ...e 2 Wind direction 3 Barometric pressure 4 Barometric trend 5 Indoor temperature 6 Outdoor temperature 7 Memory 8 Date 9 Rainfall 10 Weather forecast 11 Indoor humidity 12 Outdoor reception signal 13...

Page 5: ...manual The touch screen weather station includes a base station receiver a transmitter unit one wind direction sensor one wind speed sensor one rain gauge USB cable and a PC software package on CD RO...

Page 6: ...Assembly Mounting Connecting the Sensor 4 1 2 3...

Page 7: ...g Connecting the Sensor 5 The wind gauge s cable is connect to the input on the wind direction sensor The wind direction sensor s cable is connected to the input marked Wind on the thermo hygro sensor...

Page 8: ...Assembly Mounting Connecting the Sensor 6 The rain sensor s cable is connected to the input marked Rain on the thermo hygrosensor see fig 7 7 8...

Page 9: ...rkings in the battery compartment Replace the battery cover 2 When the batteries have been inserted all icons and symbols will be shortly displayed simultaneously Do not touch the LCD before data has...

Page 10: ...Time zone 8 for Pacific time zone 9 for Alaska time zone 10 for Hawaii time zone 3 Touch the TIME section the third time button and button will be flashing Touch the button or button to Shift the 12...

Page 11: ...mum value for 3s the maximum value will be reset to current reading Date 1 Touch the DATE section button and button will be flashing Touch the button or button to shift between alarm time date and wee...

Page 12: ...ch the button or button to change the value hold the button or button for 3s to change the number in great step 4 Touch the PRESSURE section the forth time to set the pressure high alarm function the...

Page 13: ...ge the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 3 Touch the INDO...

Page 14: ...EMPERATURE section the sixth time to display minimum outdoor temperature record the recorded minimum value will be flashing MIN icon will light up as well Hold the minimum value for 3s the minimum val...

Page 15: ...ymbols It also allows the display storage and printing of history data sets whose volume exceeding the maximum 4080 data sets of the Weather Station is only limited by the capacity of the PC s main me...

Page 16: ...500 MHz or above Memory at least 128MB 256MB recommended CD ROM Drive Base Station and PC must be connected by USB cable 3 0 Installation of the EasyWeather Software Firstly the Base Station and the...

Page 17: ...g on the base unit then you don t need to make any setting changes on the PC software However you can still easily make any setting changes you wanted from the PC and download the changes into the bas...

Page 18: ...e the corresponding alarm function Once you made your choice press Save to make the setting effective Function button display and setup system alarm value This section is used to set the desired time...

Page 19: ...e User Manual Function button display min and max recorded value This section is used to display the recorded min and max value recorded with time stamp Min Max reset can only be done through key oper...

Page 20: ...e for other application purpose When memory on base station is full press Clear Memory button to refresh the memory space on the base station remember to upload all data before pressing this button If...

Page 21: ...tory data in graph mode In this section you can see the history data plotted in graph format for easier observation If you want to see more details just use your mouse to select the area you wanted an...

Page 22: ...PC Software User Manual Function button display history data in graph mode Cont Also you can see the graph in 3D mode by selecting the 3D check box You can change the Y axis by scrolling the mouse rol...

Page 23: ...file can have different time when the PC time and base station time is not same In order to make the time scale correct remember to set the PC time and base station time same and further to this no w...

Page 24: ...e original date of purchase To claim warranty the product must be returned with a copy of the original receipt We will honour all statutory guarantees that this product is of acceptable quality includ...

Reviews: