ELECTRICAL CONNECTION
Before making any electrical connection to this unit,
check that the power supply is adequate for the voltage,
amperage and requirements stated on the rating plate.
A wiring diagram is included in the Installation &
Operations manual, which can be downloaded at
www.star-mfg.com/scripts/manuals.aspx
.
Disconnect the unit from the power source before installing or
removing any parts.
Be absolutely sure that the ground connection for the receptacle is
properly wired. Do not connect equipment to power without proper
ground connections. Improper grounding may result in personal
injury or fatality.
DO NOT CUT OR REMOVE THIS PLUG OR
GROUNDING PRONG FROM THE PLUG.
CONNECT/PLUG UNIT INTO DEDICATED
A.C. LINE ONLY SPECIFIED ON THE DATA
PLATE OF THE UNIT.
CERTAIN SURFACES ARE EXTREMELY HOT
DURING OPERATION AND CARE SHOULD
BE TAKEN WHILE USING THIS UNIT.
DO NOT IMMERSE OR LET THE UNIT STAND
IN WATER.
DO NOT HOSE DOWN THE UNIT OR THE
TABLE/COUNTER IF THE UNIT IS ON THE
TABLE/COUNTER.
KEEP AWAY FROM RUNNING WATER.
IRCS2-SBW INSTALLATION REQUIREMENTS
1. Space: 16”x24”x18”
(width x depth x height)
2. Electricity: 208/240 Volts,
30 Amps, NEMA 6-30R
Recepticale
IRCS2-NW INSTALLATION REQUIREMENTS
1. Space: 10” x 29” x 17.5”
(width x depth x height)
2. Electricity: 208/240 Volts,
12 Amps, NEMA 6-20R
Recepticale
NOTE: Ensure to clean the toaster properly before
using it for the first time. Refer to the Cleaning
Procedure document for cleaning instructions.
CAUTION
WARNING
The Holman IRCS conveyor toaster
comes with pre-programmed factory
default settings for ALL MENU
BUTTONS
.
Factory default settings are as follow:
POWER SAVER SWITCH
There are three Power Saver modes:
ON:
Unit is in pre-programmed power saving setting.
OFF:
Power Saver mode is turned off.
AUTO ON:
Power Saver turns on when there has been no activity
for a programmed length of time.
The operator may adjust the level of power reduction for the saver
mode.
(Note: conveyor may move slowly when in saver mode.)
Two buttons (+) and (-) are used when increasing or decreasing the
value of each programmable setting.
A red LED light located at the lower portion of the control panel label
will indicate if the value for top heat, bottom heat or conveyor speed
is being adjusted.
NEMA L6-30R
WARNING
WARNING
WARNING
WARNING
NEMA L6-20R
IRCS2-SBW DEFAULT SETTINGS
Menu
Buttons
Top
Heat
Bottom
Heat
Conveyor
Speed
T1
3.2
4.3
1
T2
T3
T4
T5
T6
IRCS2-NW DEFAULT SETTINGS
Menu
Buttons
Top
Heat
Bottom
Heat
Conveyor
Speed
T1
4.0
5.4
1
T2
T3
T4
T5
T6
ELECTRONIC
RADIANT-IMPINGEMENT SYSTEM
TOP HEAT
BOTTOM HEAT
CONVEYOR SPEED
SAVER
ON
OFF
T3
T4
T1
T2
T5
T6
IL2711