Symptom

Possible Cause

Suggestion

No display

Flat battery or 
no mains power or 
fuse blown

Install a charged battery. If the display 
still doesn’t work, then check the 
transformer or the main power supply. 
If main power supply is working, check 
and replace the fuse if necessary.

Station not working

Faulty solenoid coil or
Broken cable

Swap faulty station wire on controller 
terminal block with known working station 
wire.  If the faulty valve still does not work 
on the known working connection then the 
solenoid coil is faulty. The panel may need 
to be repaired or the cable may be broken.

Fuse blows

Incorrect wiring or 
bad wiring joint

Check wiring and joints for a short circuit.

No automatic start

Incorrect 
programming or 
blown fuse

If unit works manually check settings. 
Check fuse and field wiring.

System watering 
at random

Too many start 
times entered

Check number of start times entered 
and when they are scheduled to 
water. Reset the unit if necessary.