background image

PAGE 7

Before proceeding, ensure the spare watering planner
has been completed. From your planner you should be
aware which stations are allocated to each program.

Set one program at a time to ensure that the schedules
are completed correctly.

Example: 

 SET PROGRAM 1

Step 1. Set Start Times

Turn

 the dial to 

Set Start Times

 and ensure that “Prog 1”

is flashing.

The display will show:

Press

 

next

 and “Start 1” willl flash..

Press

 

next

 and the “hour” will flash. Use 

 or 

 to

adjust.  Note: Ensure AM / PM position is correct

Press

 

next

 and the “minutes” will flash. Use 

 or 

 to

adjust, if required. Each program has up to four start
times and should you require a second start time,

Press

 

next

 and “Start1” will flash. Advance to start 2 by

pressing 

.

The display will show.

Press 

next

 and proceed as per setting 

Start 1

.

Tip: To turn an active start time off, turn the dial to 

the  

Set

Start times 

position, 

Select

 the start number required

using the 

 

button and then 

press

 

next

 until the “hour”

is flashing. Use 

 or 

 until “OFF” is shown.

Tip: “OFF” position is between 12 and 1.

Programming

Programming

Set Current Time & Correct Day

Turn

 the dial to 

Set Clock/Calendar

 position. The hour

will be flashing.

Use 

 or 

 to adjust.  Note: AM / PM must be set correctly.

Press

 the 

next

 button and the “minutes” will flash. Use 

 or

 to adjust.

Press

 

next

 and the “day of the week” will flash.

Use 

 or 

 to set correct day.

Set Calendar (Optional)

Note: The calendar only needs to be set when selecting
Odd/Even day watering in areas where water restrictions
may require this feature.

Press

 

back

 button until the year, month and day are shown.

the “year” will be flashing.

Use 

 or 

 to adjust, if required.

Press

 

back

 button and the “month” will flash.

Use 

 or 

 to adjust.

Press

 

back

 and the “day” will flash.

Use 

 or 

 to adjust.

Tip

: To return to the clock,

press

 

next

, or 

turn

 dial to another position.

PAGE 6

Summary of Contents for dial ezy 4

Page 1: ...INSTRUCTION MANUAL SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID 4 6 OR 8 STATION MODELS IRRIGATION CONTROLLER ...

Page 2: ... per program or a 365 calendar for Odd Even day watering or selectable interval watering schedules from everyday to every 15th day A key feature of this controller is the water saver feature which allows quick adjustment of the station watering times by percentages as the seasons change Features Features 1 Glossary 2 Programming Instructions Introduction 3 Other Functions 4 General tips for progra...

Page 3: ... are watering similar garden areas together Examples Turf flower beds pergola areas vegetables These different groups may require individual watering schedules l Plan your watering schedule and write the information on the planner supplied at the back of this book l Set the current time and correct day of the week l Set the automatic program for each group by completing the following 3 steps 1 Set...

Page 4: ...ning A test facility for checking the valves and sprinklers is also provided General tips for easy programming Tips to help eliminate programming confusion l Complete the spare watering planner l When setting one push of the button will increment one unit l Holding one button down will fast scroll through units l During programming flashing units are able to be set using or buttons l Pressing next...

Page 5: ... active start time off turn the dial to the Set Start times position Select the start number required using the button and then press next until the hour is flashing Use or until OFF is shown Tip OFF position is between 12 and 1 Programming Programming Set Current Time Correct Day Turn the dial to Set Clock Calendar position The hour will be flashing Use or to adjust Note AM PM must be set correct...

Page 6: ...how the following This means station 1 has a default run time of 10 minutes in program 1 Station 1 will be flashing Programming Step 2 Set Watering Days This unit has interval watering or individual day selection from everyday to every 15th day or a 365 day calendar with odd even day selection in areas where water restrictions require this feature Turn the dial to Set Watering Days Interval Day Se...

Page 7: ... advance to program 2 by pressing next Programming Step 3 Set Station Run Times Continued To adjust the Run time in minutes press next and use or To set the run time in hours press next and 0 will appear and flash To adjust use or If not required press next and advance to station 2 by pressing the button Continue until all the stations in Program1 have been set with a run time or if a station or s...

Page 8: ...anual watering schedule turn the dial to the Off position Tip for automatic watering remember to turn the dial back to the Auto Run position as the Off position will stop any watering cycles from occuring Stacking Start Times Should you accidently set the same watering start time on more than one program the Controller will stack them in sequential order from the lowest number All programmed start...

Page 9: ...re maintenance work to controller or valves and when connecting and disconnecting field wiring and pump or master valve hook ups Other Features Rain Off Mode To stop the automatic watering cycles during winter turn the dial to the Off position The word Off will appear in the display This means the automatic schedules will not come on but the programmed information is still retained in the memory T...

Page 10: ...1 Prepare wires for hook up by cutting the wires to the correct length and stripping approximately 6 0mm inch of insulation from the end to be connected to the controller 2 Ensure terminal block screws are loosened sufficiently to permit easy access for wire ends Insert stripped wire ends into the clamp aperture and tighten screws Do not over tighten as this may damage the terminal block 3 A maxim...

Page 11: ...Overload protection Standard 20mm 1 Amp fuse l Power failure 9 Volt block type battery maintains clock and programs for up to 4 weeks l The output circuits should be installed and protected in accordance with wiring rules Installation Instructions Pump Hook Up Connections Do not attempt to drive a pump starter directly from the controller Pump start is provided by connecting one side of the coil o...

Page 12: ...still not responding return panel to supplier or manufacturer Check number of start times entered on each program If programming is correct return panel to supplier or manufacturer Check wiring and swap faulty station wire s on controller terminal block with known working station wire If the same outputs are still locked on return panel to supplier or manufacturer Electrician to check voltage on p...

Page 13: ...TERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 PAGE 22 Spare Watering Planner FREQUENCY OF WATERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 ...

Page 14: ...TERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 PAGE 24 Spare Watering Planner FREQUENCY OF WATERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 ...

Page 15: ...of which this product is part The guarantee shall not apply to any equipment which is found to have been improperly installed set up or used in any way not in accordance with the instructions supplied with this equipment or to have been modified repaired or altered in any way without the express written consent of the company This guarantee shall not apply to any batteries or accessories used in t...

Reviews: