3. Product Installation (continued)
1. Excavate a 20" (508 mm) diameter hole in the
desired location.
2. Run conduit or cabling at least 3" (76 mm)
deeper than the bottom of the construction
sleeve (“sleeve”).
3. Choose the ideal knockout(s) to attach conduit
or install cabling and use a tool of choice to
forcefully remove the knockout.
4. For conduit, connect to sleeve with couplings of
choice (½"-14 NPT). For cabling, install with cord
glands and torque to 50 in-lbs (5.6 Nm).
5. Remove the wiring compartment cover and pull
the wiring into the sleeve. Leave the cover inside
the sleeve to prevent loss.
6. Add installation cover onto sleeve using the
provided fasteners.
7. Insert a piece of 2" x 4" (50 mm x 100 mm)
lumber with a length in excess of the excavated
area into the cover’s slot. Secure with metal
fasteners (not provided).
8. Build a wooden frame to align and secure the
construction sleeve during the concrete pour.
9. Ensure the wooden frame aligns the top of the
cover with grade for a flush installation. To install
the faceplate slightly above grade, raise the
frame no more than ⅜" (10 mm).
36–42"