FAQ
1. Confirm that the type of the switcher is correct. The TALLY interface definition is
not unified on most switchers, so it will cause TALLY dysfunction;
2. Due to various types of the switcher, high-level value will work when push the
level switch to “High” on the TALLY signal universal converter; low-level value will
work when push the level switch to “Low” on the TALLY signal universal converter;
3. Confirm the ID of the beltpacks, and check if the TALLY converter connects with
the USB Type-A interface on the base station correctly;
4. The beltpack only supports external TALLY light. Confirm if the beltpack
connects to an external TALLY correctly;
5. DB25 INTERFACE AND TALLY INDICATOR WIRING RELATION TABLE
TALLY FUNCTION UNAVAILABLE
19
NO SOUND BETWEEN THE BASE STATION AND BELTPACK
1. Confirm if the “REMOTE MIC KILL” button on the base Station is on. If the red
light is on, click on it to turn it off.
2. Check the current status on the beltpack screen. If it’s on “MUTE”, long press the
“MUTE/TALK” button on the side to switch it to “TALK”.
3. Check if the headset functions well and if you wear the headset and mic properly.
(correct way: put the headset on the head with the mic less than 10cm from your
mouth)
Channel
Program
Preview
GND
TALLY 1
PIN 1
PIN 14
PIN 13
TALLY 2
TALLY 3
TALLY 4
TALLY 5
TALLY 6
TALLY 7
TALLY 8
PIN 15
PIN 2
PIN 16
PIN 3
PIN 4
PIN 17
PIN 18
PIN 5
PIN 19
PIN 6
PIN 20
PIN 7
PIN 21
PIN 8