II. 

Safety          

 

 

IMPORTANT Safety Items to be Observed. 

! DANGER (may cause serious damage to property and or casualties) 

1.  Please carefully read this User Manual prior to operating the instrument and observe the 

instructions on safe operation. 

2.  The power source must be grounded reliably and away from any sources of 

electromagnetic interference. 

3.  Confirm that the voltage and frequency of the power supply matches the specified 

voltage and frequency specified prior to use. 

4.  The instrument should be operated on an independent power outlet. 
5.  Do not allow the instrument to be plugged in or unplugged whilst the power switch is in 

the on position. 

6.  Do not modify the power cord. 
7.  The working environment must be free of any flammable, explosive, volatile or corrosive 

substances. 

8.  The instrument is deenergised only when the power cable is disconnected from the 

power source. 

9.  This instrument is for indoor use only. 
10. The instrument should be operated in a low humidity, well ventilated, dust, and water free 

environment, without direct sunshine or an intense magnetic, light or heat source.  
Ensure that the instrument and its accessories are free of any potential defects. 

11. Ensure that the instrument is secured tightly, and only standard accessories supplied by 

the manufacturers are used with this instrument.   

 

! WARNING (may cause property damage or personal injury) 

12. Prevent water from splashing on the electrical elements of this instrument. 
13. Before assembly, disassembly, cleaning or maintenance, the power source must be 

disconnected. 

 ! ATTENTION (may affect operational performance or service life) 

14. When pulling the power plug out from a power source, do not pull out using the power cord 

directly.

 

15. Only accredited and qualified professional repair technicians can open the instrument or 

conduct required repairs. Persons performing repairs on the instrument other than those 
selected  or  approved  by  the  Company  shall  operate  to  void  any  warranty  contained 
hereinabove for the product 

16. Do NOT operate this instrument immediately after transport, due to the Compressor await 

1-2  days  before  operating.  The  instrument  must  be  used  in  accordance  with  this  User 
Manual. 

17. Only accredited and qualified professional repair technicians can open the instrument or 

conduct required repairs. Persons performing repairs on the instrument other than those 

 

Summary of Contents for Boreas Pagoma 10308002

Page 1: ...User Manual Version 1 0 1 10308002 Boreas Pagoma Freezer User Manual...

Page 2: ...ation Warning 16 8 2 Location 16 8 3 Install Wall Bumpers 16 8 4 Install Shelves 17 8 5 Remote Alarm Contacts 17 8 6 Attach Power Cord 17 8 7 Preparing for Start up 17 8 8 Parameter Setting 18 8 9 Sta...

Page 3: ...n 1 0 3 12 5 Cleaning the Door Gasket 33 12 6 Vacuum Relief Port 33 12 7 Replacing the Battery 34 12 8 Preparing a Unit for Storage 35 12 9 Preventative Maintenance 35 12 9 1 Freezers 35 12 9 2 Mainte...

Page 4: ...the Products purchased in compliance with the applicable manufacturer s Published User Statement Limited User Statement or Limited License if any While this manual contains certain representations of...

Page 5: ...he original manufacturer or third party supplier to the extent such assignment is allowed by such original manufacturer or third party supplier In no event shall the Company have any obligation to mak...

Page 6: ...NG WITHOUT LIMITATION THOSE OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A SPECIFIC PURPOSE OR USE WHETHER ARISING FROM STATUTE OR OTHERWISE IN LAW OR FROM A COURSE OF DEALING OR USAGE OF TRADE...

Page 7: ...VING RISE TO SUCH LIABILITY OR B ONE HUNDRED THOUSAND DOLLARS 100 000 WHICHEVER IS LESS With respect to any software products incorporated in or forming a part of the Product hereunder Buyer intends a...

Page 8: ...ic light or heat source Ensure that the instrument and its accessories are free of any potential defects 11 Ensure that the instrument is secured tightly and only standard accessories supplied by the...

Page 9: ...problems are encountered or technical support is required when installing or using the instrument please contact serviceusa hollandgreenscience com The Company may provide technical assistance and in...

Page 10: ...User Manual Version 1 0 10 IV Boreas Pagoma Freezer Introduction...

Page 11: ...ure Range 50 C 58 F to 86 C 123 F in 32 C 89 6 F ambient Exterior Dimensions 35 8 W x 78 3 H x 31 4 F B 90 9cm x 199cm x 79 7cm Interior Dimensions 23 2 W x 51 6 H x 19 9 F B 58 9cm x 131 cm x 50 5cm...

Page 12: ...rmity Construction in Accordance with the following Safety Standards UL 61010 1 2012 CSA C22 2 61010 1 12 2012 UL 61010 2 011 2021 CSA C22 2 61010 2 011 2019 Construction in Accordance with the follow...

Page 13: ...ct serviceusa hollandgreenscience com The package includes the following items Part Number Description Quantity Part Number Description Quantity 1 Key 2 7 M4 screw cap 6 2 IOM 1 8 Screw trim cap 6 3 P...

Page 14: ...User Manual Version 1 0 14 VIII Installation and Operating Instructions...

Page 15: ...User Manual Version 1 0 15...

Page 16: ...for door opening Locate the freezer on a firm level surface in an area with an ambient temperature between 18 C and 32 C Provide ample room to reach the mains disconnect switch power switch located o...

Page 17: ...onnector is in the parts bag provided with the manual If you need to connect to an independent alarm system connect the alarm system to the aviation plug insert the remote alarm interface and lock the...

Page 18: ...FF state If not please set to the OFF position ON I OFF O as shown in Figure 1 10 insert the power cord into the power socket and turn on the power switch I 4 Check whether the battery switch is in th...

Page 19: ...n Log out icon blue after log in and grey after log out as shown in Figure1 13 and Figure 1 15 Options icon from left to right are Multi Unit Constraint Fingerprint Module N2 CO2 Back up System Volt S...

Page 20: ...est three records Touch the Login button and put in the login username admin and password 8888 as shown in Figure 1 14 all buttons are activated after the user logs in as shown in Figure 1 15 Touch th...

Page 21: ...s shown in Figure 1 18 The running history of the freezer are displayed in the running record page slide the right scroll bar to view more history Insert USB storage device into the right interface of...

Page 22: ...data time modification page digital keyboard pops up by touching on the numbers Put in the corresponding time to change the date or time 7 Touch the Setting button from the home page to enter the sett...

Page 23: ...d Delete User The Add User window pops up by touching the Add User button In this window you can add users and set the current user s usage rights as shown in Figure 1 22 The Delete User window pops u...

Page 24: ...r Backlight Put in the number to set the time of Screen saver Backlight The backlight intensity can be adjusted by click the or or slide the scroll bar of Backlight intensity The click tone can be set...

Page 25: ...1 26 2 Touch the Operating Log button from the display page to enter the operating log page as shown in Figure 1 27 The operation records of the current user can be viewed in the operating log page To...

Page 26: ...ature values at the point Double click on the display area of the curve to zoom in the display curve Press the display area of the curve and slide on the screen to enlarge a section of the temperature...

Page 27: ...ata will be saved to the U disk the file format is csv and they can be opened by Excel to view The history alarm information will be cleared and only the current alarm message will be retained by touc...

Page 28: ...ormation page 8 11 BOT Mode Touch the BOT button from the setting page to enter the BOT page as shown in Figure 1 33 Digital keyboard pops up by touching the blue numbers Put in the number to set the...

Page 29: ...order Then place it in the same position as the temperature sensor that needs to be calibrated Compare two temperature display values Touch the Calibration button from the setting page to enter the ca...

Page 30: ...there will be an audible alarm in the Home Page screen Press the BUZZER key to disable the audible alarm The alarms are momentary alarms only When an alarm condition occurs and then returns to normal...

Page 31: ...ature sensor Abnormal COND TEMP Disconnection of line Condenser temperature is too high Condenser temperature sensor is damaged Dust accumulated in the filter of the condenser Check for detached or lo...

Page 32: ...m 1 Open the right bottom door by pulling its bottom left corner 2 Locate the grille on the door See Figure 4 1 Grasp the middle of the grille material and gently pull out to remove 3 Wash the filter...

Page 33: ...d room temperature air out and reduce frost build up on the inner doors Because the door gasket seals so well a vacuum can be created after a door opening Warm air enters the cabinet cools and contrac...

Page 34: ...ice build up inside the tube clogging the port and inability to open the door The vacuum relief port may need to be cleaned more often with frequent door openings and high humidity environments 12 7...

Page 35: ...t to keep your unit functioning properly The operator should perform routine cleaning and maintenance on a regular basis For maximum performance and efficiency it is recommended that the unit be check...

Page 36: ...p battery See Connecting the unit to Electrical Power in Section 1 and Replacing the Battery Refer Replace Check condenser fan motor for unusual motor noise or vibration Verify and document calibratio...

Reviews: