background image

Digital Insulation

Resistance Tester

OPERATION MANUAL

1. Summary

The Digital Insulation Resistance Tester series have high

performance, and safe configuration and improved electrocircuit.
It is one new item which has more fully function, higher precision,
and easier operation. It’s also one quakeproof, dustproof and
dampproof tester and can fit work environment of outdoor.

The output testing voltage can be changed between

100V/250V/500V/1000V/2500V/5000V for different item no. The
resistance can reach 200GΩ, the tester also can measure
alternating voltage.

This Tester apply for all kinds or electric equipment and

insulation materials such as transformer, electromotor, cable,
switch, appliance, etc.

It is a perfect electrical testing meter.

2. Safety Notice

(1) Read this Operation Manual carefully before use it.
(2) This meter is designed in accordance with IEC publication

1010, pollution degree II and installation category (over
voltage category) II.

(3) Should not use it before close the back lid cause of the

danger of electroshock.

(4) Check the insulation layer of the test pin lead.
(5) Don’t rotate switch when testing.
(6) When seeing “

” on the LCD, means the battery voltage is

low. Please replace the battery or charge the battery by the
battery charger to insure accurately testing.

3. Electric Symbols

Important hint
Care for high voltage
Double insulation
Low battery

V

AC voltage

Ground

(maximum permitted voltage between terminal
and ground).

4. Feature

(1) Low power consumed CMOS double integral A/D

transforming IC, auto-checking to zero, auto displaying
polarity, displaying when low battery.

(2) LCD: 3 1/2 digits display with a max. reading of 1999
(3) Has function of holding data and displaying signal.
(4) LCD back light.
(5) Can use rotating switch when testing voltage.
(6) Voltage below AC 750V can be tested.
(7) High voltage is on the rails when LED is on.
(8) Displaying when low battery.
(9) Drove by Battery not by hand.
(10) Auto switch the range when resistance measuring.
(11) With strong load, appox.1.0mA output short current.
(12) Perfect circuit protect, preventing damage by voltage shock

effectively.

(13) Size of LCD: 68×55mm (Height of character is 35mm)
(14) Power: six battery 5# which is 1.5V (R6AA SUM-3)

(HP-6688B, C, F)

9.6V Ni-Mh charge battery (HP-6688BR, CR, FR)

(15) Size of shape: 218×122×75mm.
(16) Weight: 900g (contain battery).
(17) Environment:
Working temperature: 0

40°C,

relative humidity <80%.

Storage temperature: -10

50°C,

relative humidity <85%.

Temperature to ensure precision:
23 ± 5°C, relative humidity <75%.

5. Technique Index

Accuracies are ± ( % of r number in last digit ) for one
year
Environment temperature: 23 ± 5°C, Relative humidity <75%

Model

HP-6688B/

HP-6688BR

HP-6688F/

HP-6688FR

HP-6688C/
HP-6688CR

Insulation tester

5000V

2500V

1000V

Testing Rating

Voltage

500V/1000V/
2500V/5000V

250V/500V/

1000V/2500V

100V/250V/

500V/1000V

Output voltage

90

110% Testing Rating Voltage

Scale

1MΩ

200GΩ

1MΩ

20GΩ

1MΩ

20GΩ

Accuracy

1MΩ

200MΩ: ± ( 3.0%+5 )

200MΩ

10GΩ: ± ( 5.0%+5 )

10GΩ

200GΩ: ± ( 10.0%+5 )

Resolution

20MΩ: 10kΩ, 200MΩ: 100kΩ, 2000MΩ:

1MΩ, 20GΩ: 10MΩ, 200GΩ: 100MΩ

Scale of AC

voltage

1

750V

Accuracy

± ( 2.0%+5 )

Resolution

1V

Frequency

response

40

400Hz

Note: When you measure the resistance is less than 5MΩ in any
rating test voltage, the measuring time is not more then 10
seconds.

Remark: fall down resistance

Rating test voltage

fall down resistance

100V

1MΩ

250V

1MΩ

500V

1MΩ

1000V

2MΩ

2500V

2MΩ

5000V

8MΩ

Explaining: Fall down resistance means lower limit value of
resistance which it ensure the voltage of two extremity of
measuring is less than 90% of rating test voltage.