1. 

Overview

 

The multimeter is characterized at slim size, portable, stable performance and 
anti-dropping capacity. Using 3½  digits LCD monitor with character 16mm high, 
they  offer  clear  readings.    With  overall  circuitry  design  centering  on 
large-scale  IC  A/D  converters  in  conjunction and  over-load protection  circuit, 
the meters give excellent performance and exquisite making as a handy utility 
instrument. 
The  meters  can  be  used  to  measure  DC  &  AC  voltage,  DC  &  AC  current, 
resistance, 

capacitor, 

battery

 

positive  diode  voltage  fall,  hfe  parameters  for 

transistor and Continuity.

 

2. Panel Layout 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

① 

LCD Display: 3½  digits, character 16mm high 

② 

Data-hold Switch (HOLD) 

③ 

Back Light Button Switch: Press this button to switch on back light If the 

dark circumstance light makes the reading difficulty when measuring, the light 
will be automatically turned off in 5 seconds. Press again to switch it on again. 
If the battery is in weak power, the light will be dimmed. 

④ 

Rotary Switch: use this switch to select functions and ranges 

⑤ 

Ω

  mA    Cx+    Input Jack

Cx- Input Jack

COM    Input Jack 

3. Safety Information

 

3-1  The  meters  are  designed  according  to  IEC-1010  concerning  electronic 
measuring instruments with an over-voltage category (CAT 

) and pollution 

2. 
3-2    Follow all safety and operating instructions to ensure that the meter is 
used safely and is kept in good operating condition. 
3-3    safety symbols: 

  important safety information, refer to the operating manual. 
  Dangerous voltage may be presence. 

 

Double insulation (protection Class II) 

4. Special Cautions for Operation

 

4-1 The meters can be safe only according to standard procedures when used 
in  conjunctions  with  the  supplied  test  leads.  To  replace  damaged  test  leads 
with only the same model or same electric specifications. 
4-2    To avid risk of electric shock, do not use the meters before the cover is in 
place. 
4-3    The range switch should be right position for the testing. 
4-4    To avoid electric shock and damaging the instruments, the input signals 
are forbidden to exceed the specified limits. 
4-5    When measuring TV set or switched power, attention should be paid to 
the possible pulses that may bring destruction to the circuit. 
4-6    Range  switch  position  is  forbidden  to  be  changed  at  random  during 
measurement. 
4-7    Take  caution  against  shock  in  the  course  ot  measuring  voltage  higher 
than DC 60V & AC 30V. 
4-8    Protection  fuse  should  be  replaced  only  with  same  type  and  same 
specification. 

5. GENERAL SPECIFICATIONS 

5-1 Max Voltage between input terminal and Earth Ground: CAT 

600V   

5-2 Over-range Indication: display “1” for the significant digit. 
5-3 Automatic display of negative polarity “_” . 
5-4 Low Battery Indication: „

‟ displayed 

5-5 Max LCD display: 1999 (31/2 digits) 
5-6 Fuse protection: F-200mA/250V (Ø 5x20mm) 
5-7 Power Supply: 9V battery, 6F22 or NEDA 1604 
5-8 Operating Temp.: 0

  to 40

  (relative humidity <85%) 

5-9 Storage Temp.:-10

  to 50

  ((relative humidity <85%) 

5-10 Guaranteed precision Temp.: 23

±

  (relative humidity <85%) 

5-11 Dimension: 143x75x32mm 
5-12 Weight: approx. 200g (including battery) 

6. Testing Specifications

 

Accuracy is specified for a period of year after calibration and at 18

  to 28

 

(64

  to 82

) with relative humidity to 75%. 

6-1

    DC Voltage

 

range 

resolution 

accuracy 

200mV 

0.1mV 

±

(0.5% of rdg + 17 digit ) 

20V 

10mV 

±

(0.8% of rdg +18 digits) 

600V 

1V 

±

(0.8% of rdg + 18 digits) 

-- Input Impendence: 10M

Ω

 

-  Overload  protection:  250V  for  200mV  range,  effective  DC  or  AC  600V  for 
other ranges 

6-2    AC Voltage 

range 

resolution 

accuracy 

200V 

100mV 

±

(1.2% of rdg + 20 digits) 

600V 

1V 

±

(1.2% of rdg +20 digits) 

-- Frequency Range: 40 to 400Hz 
-- Response: average, calibrated in rms of sine wave

 

6-3    DC Current 

range 

Resolution 

accuracy 

200mA 

100μA 

± (1.5% of rdg +20 digits) 

10A 

10mA 

± (3.0% of rdg +20 digits) 

-- Overload protection: F 200mA/250V fuse    10A up to 10 seconds 

6-4    AC Current 

range 

Resolution 

accuracy 

200mA 

100μA 

± (1.8% of rdg +20 digits) 

10A 

10mA 

± (3.5% of rdg +25 digits) 

10A up to 10 seconds

 

6-5    Resistance 

range 

Resolution 

accuracy 

200

Ω

 

0.1

Ω

 

±

(1.5% of rdg + 25 digits) 

2kΩ 

1Ω 

±(0.8%

 of rdg

 +20

 digits

20kΩ 

10Ω 

±(0.8%

 of rdg

 +20

 digits

2MΩ 

1kΩ 

±(2.0%

 of rdg

 +25

 digits

-- over-load protection: 250V effective value

 

6-6 

 

Transistor hFE Test   

range 

Test Range 

Test Current / voltage 

NPN & PNP 

0-1000 

Ib=10

μ

A / Vce=3V 

6-7    Diode Test 

range 

resolution 

Function 

 

1mV 

Display: read approximate forward voltage of diode 

-- over-load Protection: 250V effective value 
-- forward DC current: approximate 1mA 
-- Reversed DC voltage: approximate 3.0V 

6-8 Continuity   

range 

Function 

 

Built-in buzzer will sound if resistance is lover than 50

Ω

 

-- over-load protection: 250V effective value 

 

open circuit voltage: approximate 3.0V 

6-9

 Capacitor

 

range 

resolution 

accuracy 

20

μ

0.01

μ

F-10

μ

0.01

μ

±

(2.5% of rdg + 30 digits) 

10

μ

F-20

μ

0.01

μ

±

(9.0% of rdg + 40 digits) 

-- over-load protection: 250V effective value 

 